background image

Mr-K

USER’S MANUAL

Содержание MR-K

Страница 1: ...Mr K USER S MANUAL ...

Страница 2: ...Dip switch 4 channel Wired remote controller 3 Introduction 8 3 1 Product description 8 4 Before using 9 5 Control buttons 9 6 User Interface 10 6 1 Status interface 10 6 2 Menu 10 6 3 DMX Interface 10 7 Operation 11 7 1 Manual Operation 11 8 Operation via DMX 11 9 Settings 12 9 1 DMX address 12 9 2 Fan speed setting 12 10 RFID card 12 10 1 How to use the card 12 10 2 How to check the remaining ti...

Страница 3: ... To avoid vibrations always place the device on a firm ground Do not use chemicals for cleaning Use a clean and dry cleaning rag to remove dust Metal parts can be cleaned with a damped cleaning rag Before cleaning always unplug the device from the power supply If the device is not working properly If problems occur unplug the device from the power supply The user should not try to service the devi...

Страница 4: ...ing objects or surfaces should not be in contact with the device Make sure that during the installation and removal of the device the area below the place of installation is basically cordoned off This also applies to implementation of service Make familiar yourself with the functions of the device before start up People without the experience should not handle with the device The most cause of fu...

Страница 5: ... the payload without suffering a permanent detrimental deformation Basically installation has to be made by using a second separate suspension This can be e g a suitable net The second suspension must be designed and attached so no part of the installation can fall down in case of failure During construction reconstruction and deconstruction unnecessary stay in the range of moving areas on lightni...

Страница 6: ... 1 Electrical connections Connect the fixture to the mains with the enclosed power cable and plug The earth has to be connected Cable EU Cable US Pin International Brown Black Live L Light blue White Neutral N Yellow Green Green Earth 6 14 ...

Страница 7: ... the red light is on then the remote control cannot be operated 4 channels can be selected suitable for 1 2 3 4 if only 1 channel is used the others are closed frequency 315MHz 2 4 Wired Remote controller When the heating process is finished the green light lights up and indicates that the button on the remote control can be pressed If heating is not complete the green light does not light up then...

Страница 8: ...missioning the unit Please follow the instructions in this manual This is the only way to ensure safe operation proper use and long service life 3 1 Product description 1 Nozzle 2 Feed port 3 Handle 4 Fuse 5 On Off switch 6 Power output 7 Power input 8 XLR 3 pol in 9 XLR 3 pol out 10 Cable controller plug 11 Induction Zone Card 12 LC Display 8 14 ...

Страница 9: ...evel surface 2 Now you have to fill in the granules More information for this you can read on the packing of the granules You are only allowed to use the granules of EWTX 3 Connect the device to the power supply 4 The device starts to heat up This process needs 5 minutes meanwhile the display shows UP 5 The heating process is finished The display shows Ready 5 Control buttons 9 14 Button Function ...

Страница 10: ...g need 5 Minutes READY The unit is ready for spark effect 6 2 Menu 6 3 DMX Interface 10 14 Menu Function Addr 1 512 Setting the DMX address Time 0030 Shows up the User time for Spark in Minutes Fan 1 10 Setting the fountain height Display Meaning 001 1 The unit is ready to work Current DMX address is 1 ...

Страница 11: ...0 255 for a fountain height of 3 5 meters depends which powder you use Indoor 3m Outdoor 5m 8 Operation via DMX Channel Value from Value to Function 0 0 No Function STOP 3 35 Height 1 36 60 Height 2 61 85 Height 3 86 110 Height 4 1 111 135 Height 5 135 160 Height 6 161 185 Height 7 186 210 Height 8 211 235 Height 9 236 255 Height 10 11 14 ...

Страница 12: ...t the fan speed through and Maximum speed is 100 10 RFID card 10 1 How to use the card Tap the IC Card to the Induction zone to activate the unit Each card enables the unit to work 30 minutes In the meantime the IC card will be invalid after being read 10 2 How to check the remaining time Press Menu buttons till the page Time to check the remaining time minutes of using Tap another new card to re ...

Страница 13: ...nsumption max 850 W Heating time 5 Minutes Consumption 14 g min Height of the fountains 1 5 Meter Number of DMX channels 1 Remote Frequency 315 MHz Yes Dmx 1 512 Yes XLR 3 pol in out Yes Power in P Con Wired remote Controller Yes Dimensions 248x244x322 mm Weight 10 1 Kg ...

Страница 14: ...______________________________________________________________________________________________________ 13 14 ...

Страница 15: ...MR K SPARK MACHINE Importer Sebo GmbH Bömmerstr 32 D 58454 Witten www sebogmbh de Info sebogmbh de 14 14 ...

Отзывы: