background image

Chapter 5

Specifications of communication & I/Os Interfaces

5.6. Embedded UMTS Modem (optional)

Specification 

UMTS Global

Bands

Quad band EGSM (850/900/1800/1900 MHz) 

Tri band UMTS/HSDPA (850/1900/2100 MHz)  

Class 

GPRS Multi-slot Class 12 

EDGE Multi-slot class 12  

Max baud rate 

230 kbps (theoretical) 

Compliant to standards 

R&TTE, CE, FCC 

Certificate number 

- - -

Antenna connector (*) 

Type SMA-F 

(*) 

Tightening torque for SMA antenna connector: MAX 0.5N.m (manual tightening should be used as 

a reference) 

See Antenna

.

5.7. Embedded HSUPA Tri-band Modem (optional)

Specification 

HSUPA

Bands

Quad band EGSM (850/900/1800/1900 MHz) 

Tri band UMTS/HSUPA (850/1900/2100 MHz)  

Class 

GPRS Multi-slot Class 12 

EDGE Multi-slot class 12  

Max baud rate 

921 kbps (theoretical) 

Compliant to standards 

R&TTE, CE, FCC 

Certificate number 

- - -

Antenna connector (*) 

Type SMA-F 

(*) 

Tightening torque for SMA antenna connector: MAX 0.5N.m (manual tightening should be used as 

a reference) 

See Antenna

.

5.8.

Embedded HSUPA Penta-band Modem EW2620B 

[Since 

S/N 1537-0108-xx included]

(optional)

Specification 

HSUPA

Bands

Quad band EGSM (850/900/1800/1900 MHz) 

Penta band HSUPA (850/900/1700/1900/2100 MHz)  

Class 

GPRS Multi-slot Class 33 

EDGE Multi-slot class 33  

Max baud rate 

921 kbps (theoretical) 

Compliant to standards 

R&TTE, CE, FCC 

Certificate number 

- - -

Antenna connector (*) 

Type SMA-F

(*) 

Tightening torque for SMA antenna connector: MAX 0.5N.m (manual tightening should be used as 

a reference) 

See Antenna

.

Page 18 / 36

eWON 2005CD | IG 001

Содержание 2005CD

Страница 1: ...support ewon biz eWON 2005CD This installation guide describes the hardware of the eWON 2005CD and explains how to get started with it Installation Guide IG 001 Rev 1 9...

Страница 2: ...tions 11 3 4 Equipment information versions 11 3 5 Mechanical Outline 12 3 6 Mounting environmental conditions 13 3 7 Preparing the installation 13 3 8 Specification for external Power Supply selectio...

Страница 3: ...26 A 2 2 Ethernet WAN 27 A 3 Direct connection 28 A 4 Connection over Hub Switch Router 29 A 5 RJ 45 Connector 29 A 6 Inputs Outputs 30 A 7 Serial Port 31 A 8 MPI Port 32 A 9 PSTN ISDN Phone line conn...

Страница 4: ...ll the benefits of an universally recognized standard network It also allows you to use popular software tools like Internet Explorer FTP client SNMP Manager Mail Recipient and so to reduce significan...

Страница 5: ...3 3 Remote Access Server functions Remote Access Server RAS and TCP IP Server PAP CHAP Authentication Login password Remote network access User access control Security NAT IP filtering Conventional a...

Страница 6: ...wer Supply 2 Low voltage 12 24DC z Serial Port type 0 RS232 RS422 RS485 6 MPI m Modem 1 No modem Ethernet only 3 ISDN EU modem 4 PSTN 56k modem 7 GPRS EDGE Quad band A HSUPA Tri band modem B UMTS Glob...

Страница 7: ...ype 2 Reference Guides Software Exhaustive reference guides to use all advanced functions of the eWON General Reference Guide RG 001 Programming Guide RG 002 Web reference guide RG 003 3 Application U...

Страница 8: ...3 Housing markings 3 Housing markings 3 1 Housing interfaces For HSUPA modem with part number EW2620A only the SIM card drawer is located on eWON top side See Embedded HSUPA modem Page 8 36 eWON 2005C...

Страница 9: ...rial Number SN is an important traceability tool both for the user and for the manufacturer Therefore next to the product label each eWON has its serial number stored in the flash memory This SN is al...

Страница 10: ...3 EU Applies to eWONs with embedded wireless modem 3 3 3 Applicable Safety Standards The eWON2005CD range including optional modems is in conformity with the following safety standards IEC EN 60950 1...

Страница 11: ...ollocated or operating in conjunction with any other transmitter or antenna To comply with regulations limiting both maximum RF output power and human exposure to RF radiation the maximum antenna gain...

Страница 12: ...lace insert the upper slider into the upper part of the rail with the eWON tiled around 20 Then push and rotate the eWON downward to put the unit right The eWON2005CD is now safely fastened For HSUPA...

Страница 13: ...s only if the following environmental conditions are respected Environment Conditions Ambient temperature range 20 C to 70 C for eWON with GPRS EDGE HSUPA modem 0 C to 50 C for eWON with PSTN or ISDN...

Страница 14: ...ter Common mode filter1 Power absorbed 10 Watts Input Protection Protected against polarity inversion Equipment Supplied by Class 2 or Level 3 Power Supply 3 8 1 Auto fuse An auto fuse placed just aft...

Страница 15: ...Chapter 4 Front panel control LED s 4 Front panel control LED s Front panel LED s description Page 15 36 eWON 2005CD IG 001...

Страница 16: ...in out RJ45 connector See RJ45 connector Please refer to the appendix Direct connection and Connection over Hub Switch Router for information on the different Ethernet connection modes straight and cr...

Страница 17: ...5 5 Embedded GPRS EDGE Quad band Modem optional Specification GPRS QB Bands Quad band EGSM 850 900 1800 1900 MHz Class GPRS Class 10 Max baud rate 40 kbps theoretical Compliant to standards R TTE CE F...

Страница 18: ...1900 2100 MHz Class GPRS Multi slot Class 12 EDGE Multi slot class 12 Max baud rate 921 kbps theoretical Compliant to standards R TTE CE FCC Certificate number Antenna connector Type SMA F Tightening...

Страница 19: ...installation Sim card installation is common to GPRS EDGE Modem GPRS quad band Modem UMTS Modem UMTS HSUPA Modem with part number EW2620B For HSUPA modem with part number EW26206B only the SIM card d...

Страница 20: ...1 is the right one Position Mode RS232 RS422 RS485 WITHOUT polarization and termination resistor RS422 RS485 WITH polarization and termination resistor Note The 3 switch configurations shown here abov...

Страница 21: ...alue Input voltage range 0 to 24 VDC Input voltage absolute max varistor protection 33 VDC Zero state max input voltage OFF 5 VDC One state voltage range ON 10 to 30 VDC One state currents ON 3 8mA 12...

Страница 22: ...bove the value specified in the eWON in order to cope with the switching power losses The transistor used is in an open drain type with pre drive This means the relay power supply has to be supplied f...

Страница 23: ...heir serial number The utility allows also to edit the IP parameters IP parameters always have to be defined in full agreement with network policies applicable within your organization ask your networ...

Страница 24: ...nication parameters 6 1 2 Factory Reset This second level reset is used only exceptionally because it formats all non volatile memories and make the eWON returning to its factory defaults This operati...

Страница 25: ...it unstable In such a case you have to redo the full reset procedure from scratch and wait until it is totally completed When performing a full reset the eWON does NOT restart in normal mode by itself...

Страница 26: ...Positive A 2 Ethernet By default only the LAN Ethernet interface of the eWON2005CDTM can be used to access the internal Web Site A 2 1 Ethernet LAN The Ethernet LAN is a four ports auto sense Etherne...

Страница 27: ...oth ends The type of cable straight or crossed depends on the equipment the eWON will be connected to The most current cases are the direct connection with a PC crossed and the connection through a hu...

Страница 28: ...use a crossover Ethernet cable to make a direct WAN connection When cabling over long distance you have to take care of the twisted pairs This means that along with the above cabling conventions the...

Страница 29: ...evice with a straight cable Again the wiring is as shown on the following picture and care should be taken to keep the RX and TX signals on twisted pairs A 5 RJ 45 Connector The RJ45 connector has got...

Страница 30: ...osition REF Description 1 DO GND Output digital signal 0V ground connected to the emitter of the transistor 2 DO Output digital signal connected to the drain of the MOSFET transistor 3 DO VDC Common o...

Страница 31: ...ial Port Mating female connector not included Type Female DB9 with 4 40 blocking screws Pin out Serial port according to mode PIN RS232 RS485 RS422 1 2 RXD RX 3 TXD A TX 4 5 GND GND GND 6 7 RTS RX 8 C...

Страница 32: ...ix A Pin outs connections A 8 MPI Port Mating male connector not included Type Male DB9 with 4 40 blocking screws MPI port pin out DB9 female PIN MPI 1 2 3 B 4 5 GND 6 7 8 A 9 Page 32 36 eWON 2005CD I...

Страница 33: ...ed Type RJ11 type 6P2C without shield PIN out PSTN PIN out ISDN PIN Description PIN Description 1 1 2 2 TX 3 TIP 3 RX 4 RING 4 RX 5 5 TX 6 6 The ISDN modem in the appliance shall be connected to the t...

Страница 34: ...850 900 1800 1900 MHz Impedance 50 Ohms Devices conformity has been assessed with the reference antenna Kinsun 6602G01081 eWON reference for the antenna is EW40923 or EW40922 for the antenna with a 2...

Страница 35: ...dem the conformity assessment has been performed with the reference antenna Taoglas TG 09 0113 eWON reference for the antenna is FAC90501_0000 or FAC90501_0100 for the antenna with a 2 meters length e...

Страница 36: ...or implicit is made concerning the quality the accuracy and the correctness of the information contained in this document In no case the manufacturer s responsibility could be called for direct indire...

Отзывы: