65
5.9.16 Expert menu (TIG)
The Expert menu has adjustable parameters stored that don’t require regular setting. The number of
parameters shown may be limited, e.g. if a function is deactivated.
ENTER
4s
EXIT
4s
Figure 5-51
Display
Setting/selection
Expert menu
Slope time (main current to secondary current)
Slope time (main current to secondary current)
activArc parameter
Parameter also adjustable after TIG activArc welding is activated.
Filler wire process (cold/hot wire)
------
filler wire activated
------
filler wire deactivated (factory setting)
Hot wire process (start signal for hot wire power source)
------- Function enabled
------- Function disabled (ex works)
Wire/pulse function (wire feeding behaviour when using pulsed TIG welding)
Wire feeding can be disabled during pulse pauses (not the case for automated
pulsing or kHz pulsing).
------- Function disabled
------- Function enabled (ex works)