Machine control
– Operating elements
Overview of control sections
10
099-00T404-EW501
02.07.2020
4.1.1
Control section A
Figure 4-2
Item Symbol
Description
0
1
Welding data display (3-digit)
Displays the welding parameters and the corresponding values
> see 4.2 chapter
2
Push-button gas test / rinse hose package
> see 5.1.1 chapter
3
Operating mode
> see 5.1.5 chapter
/ power-saving mode push-
button
> see 5.3 chapter
--------- Latched
------- Non-latched
------- spotArc spot welding procedure
– signal light turns green
------- spotmatic spot welding procedure
–signal light turns red
--------- Press button for long interval to put machine into power-saving mode.
Activate one of the operating elements to reactivate.
4
Pulsed welding push-button
TIG ------ pulsed welding
> see 5.1.6 chapter
MMA ---- pulsed welding
> see 5.2.5 chapter
5
Welding current polarity push-button
-------- DC welding with negative polarity at the torch (or electrode holder) with
respect to the workpiece.
-- Alternating current welding/alternating current forms
> see 5.1.3.3 chapter
6
Welding procedure push-button
--------- TIG welding
----- MMA welding (signal light turns green)
----- Arcforce setting (signal light turns red)
7
Display switching push-button
kW ------- Welding power display
V --------- Welding voltage display
8
Welding data display (3-digit)
Displays the welding parameters and the corresponding values
> see 4.2 chapter
9
TIG ignition type signal light
Signal light on: Lift arc ignition active/HF start off. You can switch the ignition type in the
Expert menu (TIG)
> see 5.1.11 chapter
.