EWM RTAC1 19POL Скачать руководство пользователя страница 11

 

Design and function 

General 

 

099-008197-EW501 

12.08.2013

 

11 

 

5

 

Design and function 

5.1

 

General

 

 

 

 

 

NOTE 

 

 

 

Basically, all descriptions on the process settings in the standard operating 
instructions shall apply. This operating manual exclusively describes deviating control 
functions. 

 

 

 

5.2

 

Connecting the remote control 

 

 

 

  CAUTION

 

 

 

 

Damage to the machine due to improper connection! 
The remote controls have been developed to be connected to welding machines or wire 
feed units only. Connecting them to other machines may cause damage to the 
machines! 

•  Observe the operating instructions for the welding machine or wire feed unit! 
•  Switch off the welding machine before connecting! 

 

 

 
 

 

 

 

NOTE 

 

 

 

Observe documentation of other system components when connecting! 

 

 

 

•  Switch off the welding machine 
•  Insert the male connector plug (socket) into the remote control connection socket and lock by turning 

to the right. 

•  Insert the male connector plug (pin) into the remote control connection socket of the welding machine 

and lock by turning to the right. 

5.3

 

Basic settings 

•  Preset the maximum welding current required for the welding task on the welding machine, set the 

welding parameters for the welding task correspondingly, and ensure that the unit is set to TIG 
welding. 

5.4

 

Standard Mode 

Operating 
element 

Action 

Result 

 

 

Set a reduced welding current 

 

 

Set alternating current frequency 

 

 

Set the alternating current balance

 

 

 

Содержание RTAC1 19POL

Страница 1: ...ns Remote control RTAC1 19POL 099 008197 EW501 Observe additional system documents 12 08 2013 Register now For your benefit Jetzt Registrieren und Profitieren www ewm group com Details for ewm warrant...

Страница 2: ...ther form of liability regardless of type shall be accepted This exclusion of liability shall be deemed accepted by the user on commissioning the equipment The manufacturer is unable to monitor whethe...

Страница 3: ...Warranty 9 3 2 2 Declaration of Conformity 9 3 2 3 Service documents spare parts 9 4 Machine description quick overview 10 4 1 Front view 10 5 Design and function 11 5 1 General 11 5 2 Connecting the...

Страница 4: ...l in the page margin CAUTION Working or operating procedures which must be closely observed to prevent possible minor personal injury The safety information includes the CAUTION keyword in its heading...

Страница 5: ...ess Do not press Turn Switch Switch off machine Switch on machine ENTER ENTER ENTER enter the menu NAVIGATION NAVIGATION Navigating in the menu EXIT EXIT Exit the menu 4 s Time display example wait 4s...

Страница 6: ...acemakers may be affected obtain advice from a doctor if necessary Validity of this document This document describes an accessory and is only valid in combination with the operating instructions for t...

Страница 7: ...g area must wear suitable ear protection CAUTION Obligations of the operator The respective national directives and laws must be observed for operation of the machine National implementation of the fr...

Страница 8: ...has been damaged during transport Please contact the last haulier immediately Keep the packaging for possible checking by the haulier or for the return shipment Packaging for returns If possible pleas...

Страница 9: ...Maintenance and Testing Warranty 3 2 2 Declaration of Conformity The designated machine conforms to EC Directives and standards in terms of its design and construction EC Low Voltage Directive 2006 95...

Страница 10: ...er weld seam deeper fusion penetration reduced cleaning effect lower temperature of the tungsten electrode less ball formation on the tungsten electrode 2 Alternating current frequency TIG AC 50 Hz to...

Страница 11: ...ine or wire feed unit Switch off the welding machine before connecting NOTE Observe documentation of other system components when connecting Switch off the welding machine Insert the male connector pl...

Страница 12: ...repair work trained service personnel Repair and maintenance work may only be performed by qualified authorised personnel otherwise the right to claim under warranty is void In all service matters al...

Страница 13: ...tric and electronic equipment ElektroG from 16 03 2005 used machines are to be placed in a collection system separate from unsorted municipal waste The public waste management utilities communities ha...

Страница 14: ...9 008197 EW501 12 08 2013 7 Technical data NOTE Performance specifications and guarantee only in connection with original spare and replacement parts 7 1 RTAC1 19POL Interface 19 pole Dimensions L W H...

Страница 15: ...Accessories 8 1 Connection and extension cables Type Designation Item no RA5 19POL 5M Remote control e g connection cable 092 001470 00005 RA10 19POL 10M Remote control e g connection cable 092 00147...

Страница 16: ...Appendix A Overview of EWM branches 16 099 008197 EW501 12 08 2013 9 Appendix A 9 1 Overview of EWM branches...

Отзывы: