Overview of plug (jumper) configurations
Welding data monitoring signals
42
099-000769-EW501
29.06.2015
7.6
Welding data monitoring signals
Relay outputs (X8, 12 pole)
Pin no.:
Function / Meaning
Signal form for
RINT X12
Standardisation / logic
X8/1
Welding voltage
monitoring
(Phoenix / alpha Q),
process active (Tetrix /
forceTig)
Relay output 5
2-3 ->
welding voltage OK (Phoenix /
alpha Q)
2-3 ->
end of process (Tetrix / forceTig)
X8/2
Relay output 5
1-3 ->
welding voltage error (Phoenix /
alpha Q)
1-3 ->
process active (Tetrix / forceTig)
X8/3
Relay output 5
X8/4
Welding current
monitoring,
main current signal
active (Tetrix / forceTig)
Relay output 6
5-6 ->
welding current OK (Phoenix /
alpha Q)
5-6 ->
main current phase not active
(Tetrix / forceTig)
X8/5
Relay output 6
4-6 ->
welding current error (Phoenix /
alpha Q)
4-6 ->
main current phase active (Tetrix /
forceTig)
X8/6
Relay output 6
X8/7
Wire speed monitoring
or workpiece detection
(Phoenix / alpha Q)
Workpiece detection
(Tetrix / forceTig)
Relay output 7
8-9 ->
wire speed OK (Phoenix / alpha Q)
8-9 ->
electrode/cold wire has not been
touched (Tetrix / forceTig)
X8/8
Relay output 7
7-9 ->
wire speed error (Phoenix /
alpha Q)
7-9 ->
electrode/cold wire touched
workpiece (Tetrix / forceTig)
X8/9
Relay output 7
X8/10
Motor current
monitoring
(Phoenix / alpha Q)
I>0 auxiliary process
(Tetrix / forceTig)
Relay output 8
11-12 -> motor current OK (Phoenix /
alpha Q)
11-12 -> I = 0 auxiliary process (Tetrix /
forceTig)
X8/11
Relay output 8
10-12 -> motor current error (Phoenix /
alpha Q)
10-12 -> I = 0 auxiliary process (Tetrix /
forceTig)
X8/12
Relay output 8
7.7
Analogue output signals
PIN no. Function/Meaning
Signal form for RINT X12 Standardisation logic
X11/1
Actual welding voltage value Analogue output
0...10 V
0...100 V welding voltage
X11/2
0 V
X11/3
Actual welding current value Analogue output
0...10 V
0...100 V welding current
X11/4
0 V