Overview of plug (jumper) configurations
Control voltages (nominal values)
40
099-000769-EW501
29.06.2015
7.4
Control voltages (nominal values)
Analog inputs (X6, 6 pole)
Pin no.:
Function/
Meaning
Signal form for
RINT X12
Standardisation/logic
X6/1
+10 V (Uref)
X6/2
0 V3 (Uref)
X6/3
Wire feed speed (Phoenix /
alpha Q) or welding current
(Tetrix / forceTig)
Analog input
0..10 V
()
X6/4
Voltage correction (Phoenix
/ alpha Q)/
cold wire specification
(Tetrix / forceTig)
Analog input
0..10 V (-9.9 V to +9.9 V) or
WF min 10.0 m/min
()
X6/5
Dynamics (Phoenix /
alpha Q)/secondary current
(Tetrix / forceTig)
Analog input
0..10 V (-40 to +40)
or
0..10 V
()
X6/6
Tetrix / forceTig only:
Thermal pulsing:
Pulse time
Metallurgical pulsing:
Frequency
Analog input
0...10 V
Thermal pulsing:
0.01 s to 10.00 s
Metallurgical pulsing
(1)
X6/7
Tetrix / forceTig only:
Thermal pulsing:
Pause time
Metallurgical pulsing:
Balance
Analog input
...10 V
Thermal pulsing:
0.01 s to 10.00 s
Metallurgical pulsing:
1% to 100%
X6/8
Tetrix / forceTig only:
Depending on the
configuration, nominal value
for hot wire, hot wire
oscillation frequency or filler
wire down-slope value
Analog input for special
function
Hot wire:
0..10 V equivalent to 0 to
hot wire scaling definition
Oscillation:
0..10 V equivalent to 0.1 Hz
to 16.0 Hz
Filler wire down-slope value:
0..10 V equivalent to 0 to
10.0 m/min or 24.0 m/min
0 to 5.00 m/min
()
(1)
Depending on the software version of the interface and the power source, the following scaling is
possible: 0...10 V corresponds to 50 Hz to 2500 Hz or 0...10 V corresponds to 50 Hz to 15000 Hz (-
See 9 Overview of machine software functions (firmware) chapter).