Overview of plug (jumper) configurations
Operating modes, start, machine functions
38
099-000769-EW501
29.06.2015
7.1
Operating modes, start, machine functions
Digital inputs (X5, 8 pole; X10, 12 pole)
Pin no.:
Function/
Meaning
Signal form for
RINT X12
Standardisation/logic
X5/1
0 V 4
X5/2
+24 V 1
X5/3
Non-latched mode Digital input
(- See 5.3.4 Operating modes
chapter)
X5/4
Special non-
latched mode
Digital input
(- See 5.7.2 Control signal
operation chapter)
X5/5
Pulsing/standard
Digital input
Active = Pulsing
(1)
X5/6
Ext. start 1
Digital input
Active = start welding process
X5/7
Ext. start 2 (Tetrix
/ forceTig) /
Tandem switching
(Phoenix /
alpha Q), optional
Digital input
Active = start auxiliary process
(Tetrix / forceTig)
Active = master power source
assignment (Phoenix / alpha Q)
X5/8
n.c.
X10/1
0 V 4
X10/2
24 V 1
X10/4
Control voltage
Digital input
(- See 5.3.4 Operating modes
chapter)
X10/3
Enable start
Digital input
Active = enable process
X10/5
Gas test 1
Digital input
Active = gas test 1 on
X10/6
Gas test 2 (blow
out)
Digital input
Active = gas test 2 on (blow out
machine)
X10/7
Inching/motor on
Digital input
Active = inching/motor on
X10/8
Position search
Digital input
Active = position search on
X10/9
Inching function
Digital input
Active = continuous inching
X10/10
Reverse inching
Digital input
Active = reverse inching
X10/11
Motor on (only
Tetrix / forceTig)
Digital input
Active = switch on cold wire motor
X10/12
n.c.
(1)
MIG/MAG pulse process function for machines in the Phoenix / alpha Q series, DC pulsing or AC
pulsing function for machines in the Tetrix / forceTig series (depending on the process polarity).