Design and function
Special parameters (advanced settings)
56
099-005542-EW501
24.03.2020
5.6.1 Selecting, changing and saving parameters
l
0
+
Figure 5-45
Display
Setting/selection
Wire inching / wire return ramp time
0 = ------- normal inching (10 s ramp time)
1 = ------- fast inching (3 s ramp time) (ex works)
Lat. and sp. lat. tapping start
0 = ------- no latched tapping start (Ex works)
1 = ------- latched tapping start possible
Remote control encoding (Frc)
0 ---------- Automatic remote control detection (ex works)
2 ---------- Remote control encoding for accessory components with a single rotary knob
only
9 ---------- Remote control encoding for accessory components with a single pair of but-
tons or a rocker only
1, 3–8 --- No remote control encoding
10–15 --- No remote control encoding
5.6.2 Special parameters in detail
5.6.2.1 Ramp time for wire inching (P1)
The wire inching starts with a speed 1.0 m/min for 2 secs. It is subsequently increased to a ramp function
to 6.0 m/min. The ramp time can be set between two ranges.
During wire inching, the speed can be changed by means of the welding power rotary knob. Changing the
speed has no effect on the ramp time.
5.6.2.2 Latched/special-latched tap start (P9)
In latched – tap start – operating mode it is possible to switch straight to the second step by tapping the
torch trigger; it is not necessary for current to be flowing.
The welding can be halted by pressing the torch trigger for a second time.