Design and function
TIG welding
099-002061-EW501
05.05.2020
39
5.4.5 Average value pulse welding
Average value pulse welding means that two currents are switched periodically, a current average value
(AMP), a pulse current (Ipuls), a balance (
) and a frequency (
) having been defined first. The
predefined ampere current average value is decisive, the pulse current (Ipuls) is defined by the
pa-
rameter as a percentage of the current average value (AMP). The pulse pause current (IPP) requires no
setting. This value is calculated by the machine control, so that the welding current average value (AMP)
is maintained at all times.
Figure 5-34
AMP = Main current; e.g. 100 A
Ipuls = Pulse current =
x AMP; e.g. 140% x 100 A = 140 A
IPP = Pulse pause current
Tpuls = Duration of one pulse cycle = 1/
; e.g. 1/1 Hz = 1 s
= Balance
The pulse pause current (IPP) requires no setting. This value is calculated by the machine control,
so that the welding current average value always corresponds to the main current selected.
For parameter setting,
> see 5.4.6 chapter
.
Selection
Figure 5-35