Rectifying faults
Vent coolant circuit
099-008232-EW501
26.05.2020
31
Pore formation
Inadequate or missing gas shielding
Check shielding gas setting and replace shielding gas cylinder if necessary
Shield welding site with protective screens (draughts affect the welding result)
Unsuitable or worn welding torch equipment
Check size of gas nozzle and replace if necessary
Condensation (hydrogen) in the gas tube
Purge hose package with gas or replace
Increased wear
Increased electrode wear
Plasma gas purity too low
Electrode distance too high
Insufficient water cooling
Gas supply leak
Shielding gas (argon) pre-/post-flow period too low
Increased nozzle wear
Electrode distance too high
Insufficient water cooling
Insufficient plasma gas quantity
Current limit exceeded
7.2 Vent coolant circuit
To vent the cooling system always use the blue coolant connection, which is located as deep as
possible inside the system (close to the coolant tank)!