background image

Rectifying faults 

Checklist for rectifying faults 

 

 

42 

099-005549-EW501 

12.11.2018

 

 

Functional errors 

  All machine control signal lights are illuminated after switching on 

  No machine control signal light is illuminated after switching on 

  No welding power 

 

Phase failure > check mains connection (fuses) 

  Several parameters cannot be set (machines with access block) 

 

Entry level is blocked, disable access lock

 > see 5.8 chapter

 

  Connection problems 

Make control lead connections and check that they are fitted correctly. 

   Loose welding current connections 

Tighten power connections on the torch and/or on the workpiece 

Tighten contact tip correctly 

 

Unstable arc 

  Unsuitable or worn welding torch equipment 

Adjust contact tip to wire diameter and -material and replace if necessary 

Adjust wire guide to material in use, blow through and replace if necessary 

  Material inclusions in the tungsten electrode due to contact with filler material or workpiece 

 

Regrind or replace the tungsten electrode 

  Incompatible parameter settings 

 

Check settings and correct if necessary 

 

 

Pore formation 

   Inadequate or missing gas shielding 

 

Check shielding gas setting and replace shielding gas cylinder if necessary 

 

Shield welding site with protective screens (draughts affect the welding result) 

 

Use gas lens for aluminium applications and high-alloy steels 

  Unsuitable or worn welding torch equipment 

 

Check size of gas nozzle and replace if necessary 

  Condensation (hydrogen) in the gas tube 

Purge hose package with gas or replace 

 

Содержание Phoenix 401 Expert 2.0 puls MM FKG

Страница 1: ...Operating instructions EN Welding machine Phoenix 401 Expert 2 0 puls MM FKG Phoenix 401 Expert 2 0 puls MM FKW 099 005549 EW501 Observe additional system documents 12 11 2018...

Страница 2: ...uthorised sales partners can be found at www ewm group com en specialist dealers Liability relating to the operation of this equipment is restricted solely to the function of the equipment No other fo...

Страница 3: ...cooling system 19 5 1 5 1 Approved coolants overview 19 5 1 5 2 Maximal hose package length 20 5 1 5 3 Adding coolant 20 5 1 6 Notes on the installation of welding current leads 21 5 1 7 Stray weldin...

Страница 4: ...Disposing of equipment 40 7 Rectifying faults 41 7 1 Checklist for rectifying faults 41 7 2 Vent coolant circuit 43 8 Technical data 44 8 1 Phoenix 401 FKG 44 8 2 Phoenix 401 FKW 45 9 Accessories 46 9...

Страница 5: ...must be closely observed to prevent possible minor personal injury The safety information includes the CAUTION keyword in its heading with a general warning symbol The risk is explained using a symbol...

Страница 6: ...lete documentation These operating instructions are part of the complete documentation and valid only in combination with all other parts of these instructions Read and observe the operating instructi...

Страница 7: ...en taking individual power sources out of operation all mains and welding current leads must be safely disconnected from the welding system as a whole Hazard due to reverse polarity voltage Do not int...

Страница 8: ...fire extinguishers are available in the working area Thoroughly remove any residue of flammable materials from the workpiece prior to starting to weld Only further process workpieces after they have c...

Страница 9: ...d out Recommendations for reducing interference emission Mains connection e g additional mains filter or shielding with a metal tube Maintenance of the arc welding system Welding leads should be as sh...

Страница 10: ...ions concerning the use of compressed air Do not attach any element to the shielding gas cylinder valve Prevent the shielding gas cylinder from heating up CAUTION Risk of accidents due to supply lines...

Страница 11: ...2018 11 Protective dust caps protect the connection sockets and therefore the machine against dirt and damage The protective dust cap must be fitted if there is no accessory component being operated...

Страница 12: ...lift arc MMA welding Gouging forceArc rootArc coldArc pipeSolution forceArc puls rootArc puls coldArc puls alpha Q puls MM Phoenix puls MM Taurus Synergic S MM possible not possible 3 2 Documents whi...

Страница 13: ...ll and void in the event of unauthorised interference Appoint only skilled persons for repair work trained service personnel Original copies of the circuit diagrams are enclosed with the unit Spare pa...

Страница 14: ...d quick connect coupling of coolant supply and return are only fitted in machines with water cooling Figure 4 1 Item Symbol Description 0 1 Lifting lug see 5 1 1 chapter 2 Ready for operation signal l...

Страница 15: ...Please observe the connection description for the corresponding welding procedure see 5 chapter 14 Connection socket welding current How to connect the accessories depends on the welding procedure Ple...

Страница 16: ...tton automatic cutout Wire feed motor supply voltage fuse press to reset a triggered fuse 3 PC interface serial D Sub connection socket 9 pole 4 Cooling air outlet 5 Bracket for shielding gas cylinder...

Страница 17: ...JOBs Infinite adjustment of welding performance 2 Push button gas test rinse hose package see 5 1 9 chapter 3 Push button wire inching Potential and gas free inching of the wire electrode through the...

Страница 18: ...part as possible observe option description Avoid any jerky movements Ensure that the load is distributed evenly Use chain hoists and chain slings of the same length only Stay outside the danger zone...

Страница 19: ...nsufficient frost protection in the welding torch coolant Depending on the ambient conditions different liquids are used for cooling the welding torch see 5 1 5 1 chapter Coolants with frost protectio...

Страница 20: ...e Wire feeder miniDrive Welding torch Max Compact 25 m 82 ft 5 m 16 ft 30 m 98 ft 20 m 65 ft 5 m 16 ft Decompact 25 m 82 ft 5 m 16 ft 15 m 49 ft 10 m 32 ft 5 m 16 ft Pump Pmax 4 5 bar 0 45 MPa Power s...

Страница 21: ...imum required you may need to vent the coolant circuit In this case the welding machine will automatically shut down the coolant pump and signal an error see 7 2 chapter 5 1 6 Notes on the installatio...

Страница 22: ...rs damage machines and electronic devices and cause overheating of components leading to fire Check that all welding current connections are firmly secured and electrical connections are in perfect co...

Страница 23: ...ccording to protection class I 5 1 8 1 Mains configuration The machine may be connected to a three phase system with four conductors and an earthed neutral conductor a three phase system with three co...

Страница 24: ...1 Pressure regulator connection Figure 5 7 Item Symbol Description 0 1 Pressure regulator 2 Output side of the pressure regulator 3 Shielding gas cylinder 4 Cylinder valve Before connecting the press...

Страница 25: ...r or type either a steel liner or liner with the correct inner diameter must be inserted in the torch Recommendation Use a steel liner when welding hard unalloyed wire electrodes steel Use a chrome ni...

Страница 26: ...connection socket MIG MAG welding Workpiece connection 3 Welding torch 4 Welding torch hose package 5 19 pole connection socket analogue For connecting analogue accessory components remote control wel...

Страница 27: ...or moving parts or drive components Keep casing covers or protective caps closed during operation Risk of injury due to welding wire escaping in an unpredictable manner Welding wire can be conveyed at...

Страница 28: ...sing standardised basket coils DIN 8559 see 9 chapter Figure 5 10 Item Symbol Description 0 1 Carrier pin For fixing the wire spool 2 Knurled nut For fixing the wire spool Loosen knurled nut from spoo...

Страница 29: ...xing the clamping unit and setting the pressure 4 Clamping unit 5 Wire feed roller see the Wire feed roller overview table Rotate the tommy by 90 clockwise or anti clockwise tommy locks into place Fol...

Страница 30: ...hite 0 8 0 9 1 0 030 035 040 bicolour white blue 1 0 1 2 040 045 blue red 1 4 052 monochrome green 1 6 060 black 2 0 080 grey 2 4 095 brown 2 8 110 light green 3 2 125 purple Aluminium 0 8 030 bicolou...

Страница 31: ...e inching push button and turning the wire speed rotary knob The left display shows the wire feed speed selected the right display shows the current motor current of the wire feed mechanism Depending...

Страница 32: ...g Version 2 right hand mounting Figure 5 13 Automatic inching stop Touch the welding torch against the workpiece during inching Inching of the welding wire will stop as soon it touches the workpiece 5...

Страница 33: ...t coupling red coolant return 8 Quick connect coupling blue coolant supply Insert the central plug for the welding torch into the central connector and screw together with crown nut Insert the cable p...

Страница 34: ...of the electrode holder into either the or welding current connection socket and lock by turning to the right Insert cable plug of the workpiece lead into either the or welding current connection sock...

Страница 35: ...source will ignore the external interrupt equipment and will not shut down Remove jumper 1 on the corresponding control board to be done only by qualified service personnel These accessory components...

Страница 36: ...put signal to reference potential 0 V pin E R Input Activation of control voltage specification for arc length correction S3 For activation put signal to reference potential 0 V pin E U V Output Suppl...

Страница 37: ...re Set all welding parameters on the PC and simply transfer to one or more welding machines accessory set consisting of software interface connection leads Manage up to 510 JOBs Exchange JOBs with the...

Страница 38: ...ght to claim under warranty is void In all service matters always consult the dealer who supplied the machine Return deliveries of defective equipment subject to warranty may only be made through your...

Страница 39: ...ly tighten if necessary Remove any spatter Clean the wire feed rollers on a regular basis depending on the degree of soiling 6 2 2 Monthly maintenance tasks Visual inspection Casing damage front rear...

Страница 40: ...r on wheels indicates that the equipment must be collected separately This machine has to be disposed of or recycled in accordance with the waste separation systems in use According to German law law...

Страница 41: ...lding torch equipment Adjust contact tip to wire diameter and material and replace if necessary Adjust wire guide to material in use blow through and replace if necessary Contact tip blocked Clean spr...

Страница 42: ...rc Unsuitable or worn welding torch equipment Adjust contact tip to wire diameter and material and replace if necessary Adjust wire guide to material in use blow through and replace if necessary Mater...

Страница 43: ...nt circuit Coolant tank and quick connect coupling of coolant supply and return are only fitted in machines with water cooling To vent the cooling system always use the blue coolant connection which i...

Страница 44: ...H IP 23 Residual current circuit breaker Type B recommended Noise level 3 70 dB A Ambient temperature 4 25 C up to 40 C Machine cooling Torch cooling Fan AF Gas Wire feed speed 0 5 m min up to 25m mi...

Страница 45: ...ine cooling Torch cooling Fan AF Gas or water Cooling capacity 1500 W max Flow rate 5 l min max Pump pressure 3 5 bar max Tank content 12 5 l Wire feed speed 0 5 m min up to 25m min Factory installed...

Страница 46: ...090 008088 00000 R50 7POL Remote control all welding machine functions can be set directly at the workplace 090 008776 00000 FRV 7POL 0 5 m Extension connecting cable 092 000201 00004 FRV 7POL 1 m Ext...

Страница 47: ...ct Ram protection retrofit option 092 002154 00000 ON Filter T P Retrofit option contamination filter for air inlet 092 002092 00000 ON Tool Box Retrofit option tool box 092 002138 00000 ON HS XX1 Mou...

Страница 48: ...ve for steel stainless steel and brazing 092 002770 00020 FE 4R 2 4 MM 0 095 INCH BROWN Drive roll set 37 mm 4 rolls V groove for steel stainless steel and brazing 092 002770 00024 FE 4R 2 8 MM 0 11 I...

Страница 49: ...00014 FUEL 4R 1 6 MM 0 06 INCH BLACK ORANGE Drive roll set 37 mm 4 rolls V groove knurled for flux cored wire 092 002848 00016 FUEL 4R 2 0 MM 0 08 INCH GREY ORANGE Drive roll set 37 mm 4 rolls V groov...

Страница 50: ...x A Searching for a dealer 50 099 005549 EW501 12 11 2018 11 Appendix A 11 1 Searching for a dealer Sales service parteners www ewm group com en specialist dealers More than 400 EWM sales partners wor...