Parameter overview
Figure 5-70
Basic parameters
Item
Meaning/explanation
Setting range
1
Welding current
5 A to maximum welding current
2
Hotstart time
0 to 20 s
3
Hotstart current
0 to 200 %
The hotstart current is a percentage based on the welding current selected.
5.7
Remote control
The remote controls are operated via the 19-pole remote control connection socket (analogue) or
the 7-pole remote control connection socket (digital), depending on the model.
Read and observe the documentation to all system and accessory components!
5.8
Interfaces for automation
WARNING
Do not carry out any unauthorised repairs or modifications!
To avoid injury and equipment damage, the unit must only be repaired or modified by
specialist, skilled persons!
The warranty becomes null and void in the event of unauthorised interference.
• Appoint only skilled persons for repair work (trained service personnel)!
Accessory components and the power source itself can be damaged by incorrect connection!
• Only insert and lock accessory components into the relevant connection socket when the
machine is switched off.
• Comprehensive descriptions can be found in the operating instructions for the relevant
accessory components.
• Accessory components are detected automatically after the power source is switched on.