background image

Maintenance, care and disposal 

General 

 

 

26 

099-005592-EW501 

16.07.2018

 

 

Maintenance, care and disposal 

6.1 

General 

 

 

 DANGER 

 

Risk of injury due to electrical voltage after switching off! 
Working on an open machine can lead to fatal injuries! 
Capacitors are loaded with electrical voltage during operation. Voltage remains present 
for up to four minutes after the mains plug is removed. 

1.

Switch off machine. 

2.

Remove the mains plug. 

3.

Wait for at last 4 minutes until the capacitors have discharged! 

 

 

 WARNING 

 

Incorrect maintenance, testing and repair! 
Maintenance, testing and repair of the machine may only be carried out by skilled and 
qualified personnel. A qualified person is one who, because of his or her training, 
knowledge and experience, is able to recognise the dangers that can occur while testing 
welding power sources as well as possible subsequent damage, and who is able to 
implement the required safety procedures. 

 

Observe the maintenance instructions

 > see 6.3 chapter

•  In the event that the provisions of one of the below-stated tests are not met, the machine 

must not be operated again until it has been repaired and a new test has been carried out! 

 

Repair and maintenance work may only be performed by qualified authorised personnel; otherwise the 
right to claim under warranty is void. In all service matters, always consult the dealer who supplied the 
machine. Return deliveries of defective equipment subject to warranty may only be made through your 
dealer. When replacing parts, use only original spare parts. When ordering spare parts, please quote the 
machine type, serial number and item number of the machine, as well as the type designation and item 
number of the spare part. 

Under the specified ambient conditions and normal working conditions this machine is essentially 
maintenance-free and requires just a minimum of care. 

Contamination of the machine may impair service life and duty cycle. The cleaning intervals depend on 
the ambient conditions and the resulting contamination of the machine. The minimum interval is every six 
months. 

 

6.2 

Cleaning

 

•  Clean the outer surfaces with a moist cloth (no aggressive cleaning agents). 

•  Purge the machine venting channel and cooling fins (if present) with oil- and water-free compressed 

air. Compressed air may overspeed and destroy the machine fans. Never direct the compressed air 
directly at the machine fans. Mechanically block the fans, if required. 

•  Check the coolant for contaminants and replace, if necessary. 

 

6.2.1 

Dirt filter 

The duty cycle of the welding machine decreases as an effect of the reduced cooling air volume. The dirt 
filter must be remove at regular intervals and cleaned by blowing out with compressed air (depending on 
the level of soiling). 

 

Содержание Drive 4 Basic S D200

Страница 1: ...Operating instructions EN Wire feed unit Drive 4 Basic S D200 Drive 4X Steel Synergic S D200 Drive 4X Steel puls S D200 099 005592 EW501 Observe additional system documents 16 07 2018...

Страница 2: ...uthorised sales partners can be found at www ewm group com en specialist dealers Liability relating to the operation of this equipment is restricted solely to the function of the equipment No other fo...

Страница 3: ...stallation of welding current leads 15 5 1 4 Stray welding currents 16 5 1 5 Intermediate hose package connection 16 5 1 6 Shielding gas supply shielding gas cylinder for welding machine 18 5 1 6 1 Pr...

Страница 4: ...chnical data 32 8 1 Drive 4 D200 32 9 Accessories 33 9 1 General accessories 33 9 2 Remote control connecting and extension cable 33 10 Replaceable parts 34 10 1 Wire feed rollers 34 10 1 1 Wire feed...

Страница 5: ...Contents Notes on the use of these operating instructions 099 005592 EW501 16 07 2018 5...

Страница 6: ...ng or operating procedures which must be closely observed to prevent possible minor personal injury The safety information includes the CAUTION keyword in its heading with a general warning symbol The...

Страница 7: ...n These operating instructions are part of the complete documentation and valid only in combination with all other parts of these instructions Read and observe the operating instructions for all syste...

Страница 8: ...in line with its designated purpose and by trained or expert personnel Do not improperly modify or convert the equipment 3 1 Applications MMA welding system for GMAW pulse and standard welding as a M...

Страница 9: ...horised by the manufacturer this declaration shall be voided An original document of the specific declaration of conformity is included with every product 3 3 3 Service documents spare parts and circu...

Страница 10: ...Front view side view from left Figure 4 1 Item Symbol Description 0 1 Carrying handle 2 Welding torch connection Euro or Dinse torch connector Welding current shielding gas and torch trigger integrate...

Страница 11: ...ching of the wire electrode through the hose package to the welding torch see 5 2 3 4 chapter 12 Sticker JOB List 13 Gas flow controller Fine adjustment of gas flow 14 19 pole connection socket analog...

Страница 12: ...train relief see 5 1 5 chapter 3 Wheels 4 Rotary closure Locking of the protective cap 5 Protective cap 6 Power source welding current connector plug Welding current connection between power source an...

Страница 13: ...Do not lift or suspend the machine The machine can drop and cause injuries The handles straps or brackets are suitable for transport by hand only The machine must not be suspended or lifted using a cr...

Страница 14: ...ts When changing the coolant the entire volume of liquid must be changed Dispose of the coolant in accordance with local regulations and the material safety data sheets 5 1 2 1 Approved coolants overv...

Страница 15: ...with HF igniter TIG for as long as possible in parallel with a distance of 20 cm to avoid HF sparkover Always keep a distance of at least 20 cm to leads of other power sources to avoid interferences A...

Страница 16: ...up attach or suspend all conductive power source components such as casing transport vehicles and crane frames so they are insulated Do not place any other electronic devices such as drills or angle g...

Страница 17: ...ower source Insert the hose package end through the intermediate hose package strain relief and secure with the safety belt as shown in the figure Push the welding current cable socket onto the weldin...

Страница 18: ...is a fundamental requirement for optimum welding results In addition a blocked shielding gas supply may result in the welding torch being destroyed Always re fit the yellow protective cap when not us...

Страница 19: ...a guide tube Operate welding torches with a steel liner with a capillary tube Depending on the wire electrode diameter or type either a steel liner or liner with the correct inner diameter must be in...

Страница 20: ...before the wire feed roller Loosen the welding torch connector and remove Carefully chamfer the cut off end of the liner with a liner sharpener see 9 chapter and sharpen Figure 5 10 5 2 2 Welding tor...

Страница 21: ...equipped with moving parts which can trap hands hair clothing or tools and thus injure persons Do not reach into rotating or moving parts or drive components Keep casing covers or protective caps clos...

Страница 22: ...heck the roller label to verify that the rollers are suitable for the wire diameter Turn or change if necessary use V groove rollers with for steel wires and other hard wires use U groove rollers for...

Страница 23: ...m Symbol Description 0 1 Adjusting nut 2 Feed roll tensioner Fixing the clamping unit and setting the pressure 3 Clamping unit 4 Knurled screw 5 Drive roller 6 Guide tube 7 Wire feed nipple 8 Pressure...

Страница 24: ...NING Do not carry out any unauthorised repairs or modifications To avoid injury and equipment damage the unit must only be repaired or modified by specialist skilled persons The warranty becomes null...

Страница 25: ...g torches electrode holders remote controls spare parts and replacement parts etc from our range of products Only insert and lock accessory components into the relevant connection socket when the mach...

Страница 26: ...ight to claim under warranty is void In all service matters always consult the dealer who supplied the machine Return deliveries of defective equipment subject to warranty may only be made through you...

Страница 27: ...ly tighten if necessary Remove any spatter Clean the wire feed rollers on a regular basis depending on the degree of soiling 6 3 2 Monthly maintenance tasks Visual inspection Casing damage front rear...

Страница 28: ...r on wheels indicates that the equipment must be collected separately This machine has to be disposed of or recycled in accordance with the waste separation systems in use According to German law law...

Страница 29: ...lant pump Check air cooling unit overcurrent trip 5 x Wire feeder tachometer error Check the wire feeder Tachogenerator is not emitting a signal M3 51 defective inform Service 6 x Shielding gas error...

Страница 30: ...d process gas in use is a fundamental requirement for perfect operation Legend Symbol Description Fault Cause Remedy Coolant error no coolant flowing Insufficient coolant flow Check coolant level and...

Страница 31: ...minated after switching on No welding power Phase failure check mains connection fuses Several parameters cannot be set machines with access block Entry level is blocked disable access lock Connection...

Страница 32: ...roll equipment 1 0 1 2 mm for steel wire Drive 4 rollers 37 mm Wire spool diameter Standardised wire spools up to 200 mm Welding torch connection Euro torch connector Protection classification IP 23...

Страница 33: ...Item no DM 842 Ar CO2 230bar 30l D Pressure regulator with manometer 394 002910 00030 AK300 Wire spool adapter K300 094 001803 00001 HOSE BRIDGE UNI Tube bridge 092 007843 00000 SPL Sharpener for lin...

Страница 34: ...0 1 2 Drive rollers 37 mm steel 092 000842 00000 FE 2DR4R 1 2 1 6 Drive rollers 37 mm steel 092 000843 00000 FE AL 2GR4R SF Pressure rollers smooth 37 mm 092 000414 00000 10 1 2 Wire feed rollers for...

Страница 35: ...or cored wire 092 000411 00000 URUE ROE 2DR4R 1 4 1 6 2 0 2 4 SF Conversion kit 37 mm 4 roller drive for cored wire 092 000412 00000 URUE ROE 2DR4R 2 8 3 2 SF Conversion kit 37 mm 4 roller drive for c...

Страница 36: ...x A Searching for a dealer 36 099 005592 EW501 16 07 2018 11 Appendix A 11 1 Searching for a dealer Sales service parteners www ewm group com en specialist dealers More than 400 EWM sales partners wor...

Отзывы: