Technical data
cool50 U40 / cool50 U40 115V
28
099-008598-EW501
04.04.2016
8
Technical data
Technical data limit values
The limit values determination from technical data is calculated taking account of the combined
system as a whole (cooling unit and welding machine).
8.1
cool50 U40 / cool50 U40 115V
cool50 U40 115V
cool50 U40
Supply voltage
(from the welding machine)
115 V
230 V
Mains frequency
50/60 Hz
Cooling output
1000 W (1 l/min)
Max. flow rate
5 l/min
Max. coolant outlet pressure
3.5 bar
Max. tank capacity
Approx. 4 l
Coolant
> see 5.8.1 chapter
Dimensions L/W/H in mm
610 x 298 x 330
Cooling mode/protection
classification
F/IP 23
Weight (without coolant)
16,5 kg
EMC class
A
Constructed to standards
IEC 60974-1, -2, -10