Enter Automatic Temperature Set Point 

1

 

Select zone(s)

 

 or    

2

 

Select

 

 

automatic set point

 

 

3

 

Enter temperature set point

 

 

4

 

Press enter to confirm

  

Turn zone(s) “On”

Select zone(s)

 

 or    

Press “Up”

 

 

and “Select”

 

  

 

together to turn power “On” 

4

Turn zone(s) “Off”

Select zone(s)

 

 or    

Press “Down”

 

 and “Enter”

  

  

 

together to turn power “Off” 

Select zone(s)

 

 or    

Select

 

 

automatic/manual mode

 

Enter “0” for automatic or closed loop control

 

 

 

 

Enter “1” for manual or open loop control

 

 

Press enter to confirm

  

Enter Manual % Output Set Point 

Select zone(s)

 

 or    

Select

 

 

manual % output set point

 

 

Enter manual % set point 

 

 

(0 – 99.9%)

 

 

Press enter to confirm

  

Automatic set point

Press “Up” or “Down” to adjust tem-

 

perature (Press “Up” and “Down” together 

 

to hange individual digits – 100, 10 or 1)
Select
Enter

Zone select indication 

(Press “1” and “2” together 

 

to select “both”)

Zone(s) “On”

Zone(s) “Off”

Press “1”, “2”, or  “1 & 2” together 

 

 to select “both”

Automatic/Manual mode

Select

Enter

Zone select

Manual mode light

 

 (No light = automatic mode)

Earth conductor wired to housing.

•  Female DB25 enclosure 

 

  link connector on network 

 

  module enclosure

•  Male DB25 enclosure link  

 

  connector on stacked  
 enclosure

•  Connect two enclosures 

 

  to one network module
•  Share input, output and  

 

 communications

•  Female DB9 remote computer 

 

  connector on enclosure

•  Complimentary monitoring 

 

  software including Gammavision, 

 

  Mold Monitor, Mold Doctor and 

 

  Field Calibrator

Standby input

•  24 or 120 VAC/VDC input to activate

•  All zones go to standby mode

•  If standby set point is “1”, module will be inhibited

•  Configure in Advanced Setup

•  Male insert on enclosure

Alarm output

•  22 – 265 VAC/VDC must be supplied

•  Normally open contact

•  Contact is closed when any zone is in alarm for 16 seconds

•  Fused at 5 amps

Type J

 

( - ) = White

 

 ( + ) = Black

Assignment is as follows. The actual connector arrangement of HPS-C-SLOT+ controllers may differ.

Standby 

 

input

Alarm

 

output

Thermocouple

Power

Manual % output set point

Select

Enter

Zone select

How to Enter a Set Point

How to Select Automatic or Manual

Optional Network Module Wiring

How to Turn the Power “On” & “Off”

Remote Computer & Enclosure Link Connections

HA4 Input/Output Connector

12 Zone Enclosure

2 Zone Enclosure

Standard Controller Enclosure Wiring

HPS-C-SLOT+ Controller

Version 1.0 English

Basic Operation / Advanced Setup / Troubleshooting

Thermocouple Open

Thermocouple Pinched

Thermocouple Reversed

Degrees C

Type K Thermocouple

Uncontrolled Output

Open Fuse

Shorted Heater

Open Heater

Alarm Status

Actual Temperature

Actual % Output

Actual Current (Amps)

Automatic/Manual Mode

Manual % Output Set Point

Automatic Set Point

Select

Enter

Increment (Up)

Decrement (Down)

Power “On”

Power “Off”

Standby
Boost

First Zone (Zone 1)

Second Zone (Zone 2)

Zone selected

Alarm
High Alarm

Zone “On”

Low Alarm
Manual Mode

Zone S

elect

Zone 

Status

Zone ID

Display

Actual Row

Setting Row

Entry Area

Dry cycle mold 3 – 4 times, apply full tonnage

 

 

(detects any pinched wires in advance of operation)

Turn “On” main disconnect

Select

 

 

automatic set point

 

  

  

Select Zone 1

 

, Zone 2

 

 

or “both”

 

 

  

 

Enter automatic set point

 

 

. Press enter

  

 

 

Repeat for other zones or modules

Select

 

 

automatic/manual mode

 

  

 

Select Zone 1

 

, Zone 2

 

 

or “both”

 

 

  

 

Enter “0” for automatic

 

 

. Press enter

  

  

 

Repeat for other zones or modules

Select Zone 1

 

, Zone 2

 

 

or “both”

 

 

  

 

Press “Up”

 

 

and “Select”

 

 

together (Power “On”)

 

 

 

Apply power to manifolds first (heat up large mass first)

 

  

Repeat for other zones or modules

Zones will read a low temperature alarm

 

 

Zones are close or holding set point when the

 

 

green temperature holding set point light is illuminated

Automatic set point

Automatic/manual mode

Press “Up” and “Select” 

 

together (Power “On”)

 

 
 

Press “Down” and “Enter” 

 

together (Power “Off”)

Zone select indication 

(Press “1” and “2” together to select “both”)

Temperature holding set point (Zone “On”)

Low temperature alarm

HPS-C-SLOT+ Start Up Procedure

EWIKON Heißkanalsysteme GmbH

 

Siegener Straße 35, 35066 Frankenberg

 

Tel: +49 (0)64 51/50 10 ∙ Fax: +49 (0)64 51/50 12 02

 

[email protected] ∙ www.ewikon.com

6 Zone Enclosure

Power

Thermocouple

Earth conductor wired to housing.

Earth conductor wired to housing.

Zone

Load 

PIN

Temperature 

sensor PIN

1

1 / 6

5(+) / 10(-)

2

3 / 8

4(+) / 9(-)

Zone

PIN

1

1 / 9

2

2 / 10

3

3 / 11

4

4 / 12

5

5 / 13

6

6 / 14

Zone

PIN

1

1 + / 9 -

2

2 + / 10 -

3

3 + / 11 -

4

4 + / 12 -

5

5 + / 13 -

6

6 + / 14 -

Type J

 

( - ) = White

 

 ( + ) = Black

Zone

PIN

1

1 / 13

2

2 / 14

3

3 / 15

4

4 / 16

5

5 / 17

6

6 / 18

7

7 / 19

8

8 / 20

9

9 / 21

10

10 / 22

11

11 / 23

12

12 / 24

Zone

PIN

1

1 + / 9 -

2

2 + / 10 -

3

3 + / 11 -

4

4 + / 12 -

5

5 + / 13 -

6

6 + / 14 -

7

7 + / 15 -

8

8 + / 16 -

9

17 + / 25 -

10

18 + / 26 -

11

19 + / 27 -

12

20 + / 28 -