Enter Automatic Temperature Set Point
1
Select zone(s)
,
or
2
Select
automatic set point
3
Enter temperature set point
4
Press enter to confirm
Turn zone(s) “On”
1
Select zone(s)
,
or
2
Press “Up”
and “Select”
together to turn power “On”
4
Turn zone(s) “Off”
1
Select zone(s)
,
or
2
Press “Down”
and “Enter”
together to turn power “Off”
1
Select zone(s)
,
or
2
Select
automatic/manual mode
3
Enter “0” for automatic or closed loop control
Enter “1” for manual or open loop control
4
Press enter to confirm
Enter Manual % Output Set Point
1
Select zone(s)
,
or
2
Select
manual % output set point
3
Enter manual % set point
(0 – 99.9%)
4
Press enter to confirm
Automatic set point
Press “Up” or “Down” to adjust tem-
perature (Press “Up” and “Down” together
to hange individual digits – 100, 10 or 1)
Select
Enter
Zone select indication
(Press “1” and “2” together
to select “both”)
Zone(s) “On”
Zone(s) “Off”
Press “1”, “2”, or “1 & 2” together
to select “both”
Automatic/Manual mode
Select
Enter
Zone select
Manual mode light
(No light = automatic mode)
Earth conductor wired to housing.
• Female DB25 enclosure
link connector on network
module enclosure
• Male DB25 enclosure link
connector on stacked
enclosure
• Connect two enclosures
to one network module
• Share input, output and
communications
• Female DB9 remote computer
connector on enclosure
• Complimentary monitoring
software including Gammavision,
Mold Monitor, Mold Doctor and
Field Calibrator
Standby input
• 24 or 120 VAC/VDC input to activate
• All zones go to standby mode
• If standby set point is “1”, module will be inhibited
• Configure in Advanced Setup
• Male insert on enclosure
Alarm output
• 22 – 265 VAC/VDC must be supplied
• Normally open contact
• Contact is closed when any zone is in alarm for 16 seconds
• Fused at 5 amps
Type J
( - ) = White
( + ) = Black
Assignment is as follows. The actual connector arrangement of HPS-C-SLOT+ controllers may differ.
Standby
input
Alarm
output
Thermocouple
Power
Manual % output set point
Select
Enter
Zone select
How to Enter a Set Point
How to Select Automatic or Manual
Optional Network Module Wiring
How to Turn the Power “On” & “Off”
Remote Computer & Enclosure Link Connections
HA4 Input/Output Connector
12 Zone Enclosure
2 Zone Enclosure
Standard Controller Enclosure Wiring
HPS-C-SLOT+ Controller
Version 1.0 English
Basic Operation / Advanced Setup / Troubleshooting
Thermocouple Open
Thermocouple Pinched
Thermocouple Reversed
Degrees C
Type K Thermocouple
Uncontrolled Output
Open Fuse
Shorted Heater
Open Heater
Alarm Status
Actual Temperature
Actual % Output
Actual Current (Amps)
Automatic/Manual Mode
Manual % Output Set Point
Automatic Set Point
Select
Enter
Increment (Up)
Decrement (Down)
Power “On”
Power “Off”
Standby
Boost
First Zone (Zone 1)
Second Zone (Zone 2)
Zone selected
Alarm
High Alarm
Zone “On”
Low Alarm
Manual Mode
Zone S
elect
Zone
Status
Zone ID
Display
Actual Row
Setting Row
Entry Area
1
Dry cycle mold 3 – 4 times, apply full tonnage
(detects any pinched wires in advance of operation)
2
Turn “On” main disconnect
3
Select
automatic set point
Select Zone 1
, Zone 2
or “both”
Enter automatic set point
. Press enter
Repeat for other zones or modules
4
Select
automatic/manual mode
Select Zone 1
, Zone 2
or “both”
Enter “0” for automatic
. Press enter
Repeat for other zones or modules
5
Select Zone 1
, Zone 2
or “both”
Press “Up”
and “Select”
together (Power “On”)
Apply power to manifolds first (heat up large mass first)
Repeat for other zones or modules
6
Zones will read a low temperature alarm
Zones are close or holding set point when the
green temperature holding set point light is illuminated
Automatic set point
Automatic/manual mode
Press “Up” and “Select”
together (Power “On”)
Press “Down” and “Enter”
together (Power “Off”)
Zone select indication
(Press “1” and “2” together to select “both”)
Temperature holding set point (Zone “On”)
Low temperature alarm
HPS-C-SLOT+ Start Up Procedure
EWIKON Heißkanalsysteme GmbH
Siegener Straße 35, 35066 Frankenberg
Tel: +49 (0)64 51/50 10 ∙ Fax: +49 (0)64 51/50 12 02
[email protected] ∙ www.ewikon.com
6 Zone Enclosure
Power
Thermocouple
Earth conductor wired to housing.
Earth conductor wired to housing.
Zone
Load
PIN
Temperature
sensor PIN
1
1 / 6
5(+) / 10(-)
2
3 / 8
4(+) / 9(-)
Zone
PIN
1
1 / 9
2
2 / 10
3
3 / 11
4
4 / 12
5
5 / 13
6
6 / 14
Zone
PIN
1
1 + / 9 -
2
2 + / 10 -
3
3 + / 11 -
4
4 + / 12 -
5
5 + / 13 -
6
6 + / 14 -
Type J
( - ) = White
( + ) = Black
Zone
PIN
1
1 / 13
2
2 / 14
3
3 / 15
4
4 / 16
5
5 / 17
6
6 / 18
7
7 / 19
8
8 / 20
9
9 / 21
10
10 / 22
11
11 / 23
12
12 / 24
Zone
PIN
1
1 + / 9 -
2
2 + / 10 -
3
3 + / 11 -
4
4 + / 12 -
5
5 + / 13 -
6
6 + / 14 -
7
7 + / 15 -
8
8 + / 16 -
9
17 + / 25 -
10
18 + / 26 -
11
19 + / 27 -
12
20 + / 28 -