Operating Voltage
:
AC220V
±
10% 50HZ/60HZ
2
、
Load Current
:
10A/220V/AC
3
、
Power Consumpion
:≤
3W
4
、
Working Environment
:-
10
℃ ~
50
℃
RH
≤
90%
5
、
Control Range
:-
70
℃~
400
℃/-
70
℃~
800
℉
6
、
Resolving
:
1
℃
accuracy
:±
3
℃
7
、
Input Signal: One way PT100 ( equipped by user )
8
、
Output
:
one
-
way
contro
9
、
Overall Dimension
:
78(length)
×
35(wide)
×
62(high)mm
10
、
Starter
:
71(length)
×
29(wide)mm
Temperature difference
Setting range: 1 ° C ~ 15 ° C or
1°F
~
60°F
High temperature alarm.
Setting range: (control tempe d + 1) ° C ~ 415 ° C
Or (control temped+1) °F ~ 800 °F
Temperature correction.
Setting range: -25 ° C ~ 25 ° C or
-60 ° F ~ 60 ° F
Delayed start.
Setting range: 0 to 3 minutes
《
EW-986GP
》
Directions
Microcomputer Thermostat Serial
Firstly thanks for using our instrument. This product is
a new product of fully automatic intelligent control sy-
stem especially made for high-temperature and heating
industry.
1.The voltage must accord with controller's demand. The
voltage's deviation is no more than
±
10%.
2.The loop of sensor is possible to keep away from the
loop of power.
3.The sequence of line's must have been connected
Properly.
版 本
:986GP.18.09.06
When the current temperature
and the
temperature value is rotated displayed.
> .
When it is
cooling state, it enters the fault running state.
(ON for 45 minutes, OFF for 15 minutes); When
the state of heating relay OFF.
When the current temperature < , and the
temperature value is rotated displayed. When it is
heating state, continue heating; If cooling state
the relay d
.
isconnect
Set
PV
SV
。
C
!
Heating System Indicator
Fault Indicator
Current
Temperature
Setting
indicator
Set
SV
Set
SV
Set
SV
Set
SV
Set
SV
Set
PV
!
Set
PV
!
Temperature conversion:
C is displayed in Celsius temperature,
F is Fahrenheit temperature display
Set
PV
Set
SV
Cooling System Indicator
Cooling heating conversion. Under this menu,
press or first time to display the original
set value.Press again to modify the set value.
Setting range: H or C
Low temperature alarm.
Setting range: -75 °C ~ (control temperature - d-1) °C
Or -75 °F ~ (control temperature - d-1) °F
When the sensor line is open or shorted, an E1 alarm.
If the controller is in the cooling state, it enters the
fault operation state (ON for 45 minutes, OFF for 15
minutes); when it is heated, the relay is disconnected.
Set
PV
!
3. Reset: Non-set state, press for 5 seconds, the display
flashes, all parameters are reset to factory settings
1 .
,
SV light ON,
o r
The setting range is also limited by and . Please
see the parameter settings below for details.
Temperature setting: Press
display con
trolling temperature, press
to change controlling temp-
erature..
2.
Parameter Setting: Press for 6 seconds to start parameter
setting, will be displayed. Press to adjust the parameters
of
。
Technical Specifications
Brief on Operation
Demand of install
Operating Procedure