EW-983A Directions

Microcomputer Thermostat Serial

Technical Specifications

1

:  AC220V      

±

10

    50HZ/60HZ

2

: 5A/220V/AC

3

: ≤

3W   

4

10

℃~

50

    R H

90%

5

Controlled Output: one for compressor and 

                                         one for four-way valve.

6

: ℃ ~

80

7

1

       

: ±

1

8

Defrosting with water and condenser uses one sensor 

respectively. The standard length is 1.5m ( The maximum 

extension can be 50m. The extended cable  should be shielded.)

9

×

×

10

×

Operating voltage

Load current

Power Consumption

Working environment

Control Range

1

Resolving Power

Accuracy

Overall Dimension

76(length)

40(wide)

67(high)mm

Starter Size:   71(length)

29(wide)mm

Low-pressure Muffler

Heat Preservation Material

Defrosting Sensor

Evaporator

Evaporator

Evaporator

Evaporator

Evaporator

Evaporator

Evaporator

Evaporator

Evaporator

Evaporator

Evaporator

Wiring diagram

Code: 983AH.16.08.18

2 flashes

3 flashes

4 flashes

Temperature
correction

All four lights
simultaneously
flash

-3

18

3

2

00

Minutes

1

15

-39~0

5

35

0

5

-15

15

2

3 flashes

Setting range

12

1

80

Parameters for Procedure

Brief on Operation

Demand of install

Attention please:

when setting "HS", the ruler is:  "HS" > ("setting-

    temperature" + "d").

When setting "LS", the ruler is:  "LS" > ("setting-

    Temperature" 

 "d").

Setting Range

Function

Unit

Ex-factory 

Value

Set delayed
 time

Different

Indicator

End defrost

1 flashes

Start defrost

          Firstly thanks for using our instrument. This product is a 

control system especially developed for the machine integrated 

with refrigeration and heating for seafood pool. It is an automa-

tic change of refrigeration and heating and defrosting function.

         Our sensor is especially precisely made and sealed;  it is   

moisture-proof , therefore its performances are more stable and 

reliable.

     1. Setting of Control Temperature: Slightly press        to display 

control temperature and light 2 and light 3 will flash. Press        or

       to change control temperature.

     2. Parameter Setting: Hold         for six seconds to enter setting 

process and the indicator light will flash. Press         each time for 

the change of function. Press          or        to change the parameters 

for each function. The modified parameter will be automatically 

memorized.

The sensor is stalled 5 to 10cm away.

When light 1 is
 always on

When light 1 is
 always on

When light 1 is
 always on

Run at refrigeration mode. The compressor
works independently.

Run at defrosting mode. The compressor 
and four-way valve work.

Run at heating mode. The compressor and 
four-way valve work.

Demonstration now
 temperature

EW-983A

Load

220V/AC

Model

EW-983AH

5A              5A

Defrosting
Sensor 

 

 

Water Temperature
 Sensor

C o n t r o l l e d 

Compressor

For-way 
valve