background image

setting 
temperature

Function

Setting 
Range

temperature 
difference

Operating 
cycle

Defrost time

Delay time

LS

+

1

HS

-

1

1,0

15,0

1

99

1

45

5,0

35,0

1

5

General settings:

Exit 
temperature

1

:  AC220V      

±

10

    50HZ/60HZ

2

: 5A/220V/AC

3

:≤

3W   

4

10

℃~

50

    R H

90%

5

:-

0.0

℃ ~

50.0

6

1.0

       

: ±

1.0

7

Input signal

:

×

×

×

Operating voltage

Output Load 

Power Consumption

Working environment

Control Range

5

Resolving Power

Accuracy

Overall Dimension

120(length)

53(wide)

84(high)mm

Starter Size:   92(length)

44(wide)mm

8

Evaporator fan operation mode: fan is provided with 

      normally open, start / stop, delay (1 ~ 5 minutes 

      adjustable) operation.

9

Defrost mode: electric or steam defrosting.

10

Manual / automatic defrosting: forced entry and exit 

        defrosting, defrosting exit time and temperature of 

        double insurance.

11

 

12

 two-way storage temperature sensor, 

                              10Kx1.5mx2

版本:

286A-2016.08.16

Microcomputer Thermostat Serial

EW-286 

Directions

  Welcome to choose our instruments. This product 
is a specialize micro-computer temperature  
controller for refrigerator and freezer. The panel in 
English takes it easy to use and avoid entering 
confusing menu represents the parameter setting. 
Our sensor is precisely ma-de and sealed. It is 
moisture proof, therefore its performances are more 
stable and reliable. 

Ex-factory 

Value

Hour

Unit

Notes.

Temperature 
correction

-15,0

15,0

-10,0

3,0

6

10

3

5,0

0,0

Mins

Mins

When reaching the set 

temperature, the compressor 

control switch OFF

Heating to the set tempe return 
difference, compressor control 
switch connected

Interval between two

 defrosting

Working

 

time

 

of

 

deforsting

Delay time before staredt

Defrosting ending 
temperature

Hold

    

a n d

    

6nds

 

to

 

set

 

this

 

value

Advanced Settings:

Code

Function

Upper limit

Lower

 

limit

Dripping
 time

Defrost 
mode

Evaporator
Fan Mode

Setting Range

-

50 to temp control -1

Temp c1 to 50

-

1

5

0

10

0

1

Ex-factory 

Value

 50,0

-50,0

01

2

0

Unit

Mins

Notes.

Exceeds a set value 
alarm

Exceeds a set value 
alarm

Parameters: when “-1” 
the fan normally open;
 when “0”, the fan and 
compressor start with 
the same stop, compressor 
start delay after 1-5 
minutes.

Each delay time after 
defrosting, and “0” for 
no dripping time

When set to “0” is 
electric defrosting
When set to “1” is 
steam defrosting

220V/AC

Mode: EW-286A

220V/AC

E

v

a

p

o

ra

to

fa

n

D

e

fr

o

st

Storehouse 

sensor

Defrost

sensor

Output Load:
5A/220V/AC

1

2

3

4

5

6

7

8

9

0 1

1

1

1

1

1

1

2

3

4

5

5A         5A        5A        5A

A

la

rm

C

om

pr

es

so

r

Technical Specifications

Appearance Panel

heat

temp

heat

time

up

set

down

Evaporator

Thermal insulating material

Defrosting sensor

Low-voltage air-return pipe

The sensor is installed the distance 5-10cm.

Wiring diagram

Parameters for Procedure