background image

Electric Vehicle Supply Equipment 

By Control Module Inc, EVSE LLC 

State of the Art EVSE with Cable Management 

Electrician EVSE Tester 

Model 3840-001

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User Guide  

Model 3840-001 

Electrician EVSE Tester 

Patents Pending 

3840-UG-001  

February 2018 

Содержание 3840-001

Страница 1: ...pply Equipment By Control Module Inc EVSE LLC State of the Art EVSE with Cable Management Electrician EVSE Tester Model 3840 001 User Guide Model 3840 001 Electrician EVSE Tester Patents Pending 3840 UG 001 February 2018 ...

Страница 2: ...ompliance Statement 2 Important 2 No Accuracy Guarantee 2 Copyright and Trademarks 2 Instructions Pertaining To Risk of Fire or Electrical Shock 2 Instructions De Sécurité Importantes 4 Introduction to the Model 3840 Electrician EVSE Tester 5 Specifications 6 Product Description 7 Operation 8 Fault Conditions 11 User Maintenance 12 Moving Transporting and Storage 13 Customer Support 14 Warranty 15...

Страница 3: ...C Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is li...

Страница 4: ... with an internal power line fuse Do not attempt to replace this fuse Return the defective unit to Control Module Inc EVSE LLC for repair or replacement Tampering with the Model 3840 could cause serious damage to the unit Keep the connector on the Model 3840 clean and dry Failure to do so may result in a false ground fault trip To reduce the risk of fire ensure EVSE connection only to a dedicated ...

Страница 5: ... modèle est protégé par un fusible de ligne alimentation interne N essayez pas de remplacer ce fusible Reprendre Control Module Inc EVSE LLC pour la réparation ou le remplacement de l unité défectueuse Falsification de la 3840 modèle pourrait causer un préjudice grave à l unité Garder le connecteur sur le 3840 modèle propre et sec Omission de le faire peut entraîner un voyage faute de faux motif A...

Страница 6: ...ers SAE J1772 publications This unit will test any manufacturer model EVSE that complies with the SAE J1772 standards The Model 3840 will measure signal levels pulse widths and voltage levels generated by the EVSE under test and will indicate to the operator Electrician the results of the measurement using high intensity LED s The Model 3840 also allows the operator to test important safety featur...

Страница 7: ...e 0 to 5VDC 0 1 accuracy Safety Features_________________________________________________________________________________ Internal Fuse Not user replaceable Compliance____________________________________________________________________________________ Safety IEC UL CSA C22 2 61010 1 NEC Article 625 SAE J1772 EMC FCC Part 15 Class A Canadian ICES 003 Environmental___________________________________...

Страница 8: ...rmined by the pulse width of the pilot signal received from the EVSE under test 4 Charge on off toggle switch necessary to activate the EVSE under test 5 LED indicator to denote when the input voltage is between 95 and 125V AC 6 LED indicator to denote when the input voltage is between 185 250V AC 7 LED indicator to denote the presence and accuracy of the incoming pilot signal 8 LED indicator to d...

Страница 9: ...250V AC Measures incoming pilot signal amplitudes up to 15V DC with 0 1 accuracy Measures pilot signal frequency IKC with 0 1 accuracy Measures pilot signal pulse width 0 to 95 duly cycle with 0 1 accuracy Measures the proximity switch resistor with 0 1 accuracy Controls 110V AC and 220V AC indicator LEDs Controls pilot and proximity switch indicator LEDs Controls seven current range indicator LED...

Страница 10: ...and as a self test will sequentially light all of the status LEDs The microprocessor will then measure the voltage on Pins 1 and 2 and depending on the amplitude will light either the 110VAC or 220VAC status LED When the AC voltage is between 185VAC and 250VAC the 220V status LED is turned on steady When the AC voltage is between 95VAC and 125VAC the 110V status LED is turned on steady When the vo...

Страница 11: ...lt Conditions All status LEDs on the Model 3840 will turn off Most EVSE manufacturers will provide an automatic reclosure after a ground fault interception Wait the specified time and the EVSE should once again supply voltage to the Model 3840 tester If not see Fault Conditions The EVSE test is now completed EVSE Protection Breaker The minimum breaker size shown in the chart is for reference only ...

Страница 12: ... Pilot status LED OFF Pilot frequency outside specification Pilot status LED flashes Note 1 Pilot voltage outside specification Check Pin 4 to ground Pin 3 Should be between 11 to 13VDC Press proximity locking latch on J1772 Connector Proximity status LED flashes Locking latch not fully engaged Measure resistance between Pin 5 and ground Pin 3 Should be 150 ohms and change to 480 ohms when lock la...

Страница 13: ... 12 User Maintenance Perform the following preventative maintenance at least monthly The J1772 inlet should be checked for foreign matter cleaned and dried with a mild detergent safe for plastics and then allowed to dry Report mechanical damage ...

Страница 14: ...ng Transporting and Storage Retain the original shipping materials Should the Model 3840 001 Electrician EVSE Tester need to be returned to the factory or be otherwise shipped use the original packing materials Store the unit in a dry low humidity area ...

Страница 15: ...features maintenance or service arise please call Technical Support at 1 888 753 8222 between the hours of 8 30 am to 5 00 pm EST Monday to Friday Letter Service Department Attn Jack Batalha Director Product Support Control Module Inc 89 Phoenix Avenue Enfield CT 06082 Fax 1 860 741 6064 E mail jbatalha controlmod com ...

Страница 16: ...3840 001 User Manual February 22 2018 Page 15 Warranty For Standard Terms and Conditions and Warranty information http controlmod com technical support order terms ...

Страница 17: ...0 745 2433 Toll Free Phone 800 722 6654 evse controlmod com EVSE LLC A Division of Control Module Inc 89 Phoenix Ave Enfield CT 06082 Local Phone 860 745 2433 Toll Free Phone 800 722 6654 EVSE LLC A Division of Control Module Inc 89 Phoenix Ave Enfield CT 06082 Local Phone 860 745 2433 Toll Free Phone 800 722 6654 evse controlmod com ...

Отзывы: