EVS Synapse U4D100 Скачать руководство пользователя страница 1

Synapse

U4D100

4-Wire 4K Ultra HD to 1080p Down Converter

Version 1.00 | November 2021

INSTALLATION AND OPERATION MANUAL

Содержание Synapse U4D100

Страница 1: ...Synapse U4D100 4 Wire 4K Ultra HD to 1080p Down Converter Version 1 00 November 2021 INSTALLATION AND OPERATION MANUAL ...

Страница 2: ......

Страница 3: ...rmational purpose and use only and subject to change without notice This manual cancels and replaces any previous versions thereof Copyright Copyright 2003 2021 EVS Broadcast Equipment SA All rights reserved This manual may not be reproduced transcribed stored in a database or a retrieval system translated into any language computer language transmitted in any form or by any means electronically m...

Страница 4: ...o repair this product If a problem occurs contact your local EVS distributor NEVER expose this product to extremely high or low temperatures NEVER operate this product in an explosive atmosphere To reduce the risk of fire or electrical shock do not expose this appliance to rain or moisture This product complies with the requirements of the product family standards for audio video audio visual ente...

Страница 5: ... Parameters 3 3 2 Using Cortex with Synapse 5 4 The U4D100 Card 6 5 Settings Menu 8 5 1 Introduction 8 5 2 System Settings 8 5 3 Network 11 6 Status Menu 12 6 1 Introduction 12 6 2 System Status 12 6 3 Net Status 12 7 Events Menu 13 8 LED Indication 15 9 Block Schematic 16 10 Connector Panels 17 INSTALLATION AND OPERATION MANUAL Synapse U4D100 Contents iii ...

Страница 6: ...GNU Public License 18 ICONOGRAPHY Note Tip Warning iv November 2021 Issue 1 00 B ...

Страница 7: ...d on the left margin to highlight information on updated features The changes linked to new features in version 1 00 of U4D100 are listed below SMPTE ST 352 Payload Identifier See section System Settings on page 8 INSTALLATION AND OPERATION MANUAL Synapse U4D100 What s New v ...

Страница 8: ......

Страница 9: ...efer to the RRC18 RRC10 RRC04 RRS18 and RRS04 manuals for a detailed description of the local control panel the way to set up remote control over IP and for frame related settings and status information Remote Control Capabilities The remote control options are explained in the rack controller RRC18 RRC10 RRC04 RRS18 RRS04 ERC108 118 ERS108 118 manuals The method for connecting to a computer using...

Страница 10: ...of components mounted on the board Placing the Card The Synapse card can be placed vertically in an SFR18 frame or horizontally in an SFR04 and SFR08 frame Locate the two guide slots to be used slide in the mounted circuit board and push it firmly to locate the connectors Correct insertion of the card is essential as a card that is not located properly may show valid indicators but will not functi...

Страница 11: ...hapters of this manual Please refer to Settings Menu on page 8 Status Menu on page 12 Graphical User Interface on page 1 and Events Menu on page 13 Front Panel Control Front Panel Display and Cursor Settings are displayed and changed as follows Use the cursor arrows on the front panel to select the menu and parameter to be displayed and or changed Move forward through the menu structure Go back th...

Страница 12: ...Status Events The display changes to indicate that the SFS10 Settings menu item SDI Format has been selected and shows that its current setting is Auto Pressing the selects the Settings item shown in this example SDI Format Pressing or will change to a different setting e g Mode H Delay The display changes to indicate that the SFS10 Edit Setting menu item SDI Format has been selected To edit the s...

Страница 13: ... modules Each Synapse frame is addressed through its rack controller s unique IP address giving access to each module its menus and adjustment items Cortex has access to data contained within the Synapse module and displays it on a GUI The software has an intuitive structure following that of the module that it is controlling For operation of Cortex please refer to the Cortex help files Further in...

Страница 14: ...Low latency 1 1080p Frame 20ms 50Hz 16 7ms 59 94 Hz 4 wire 4K 3840 x 2180 Compatible with the following formats auto selecting 1080p 59 94 1080p 50 Transparent for 16 channels of embedded audio The BPH17 can optionally be fitted with up to two fiber I O modules inputs or outputs Full control and status monitoring through the front panel of the SFR04 SFR08 SFR18 frame and the Ethernet port ACP Appl...

Страница 15: ...Block Schematic INSTALLATION AND OPERATION MANUAL Synapse U4D100 4 The U4D100 Card 7 ...

Страница 16: ...enu settings that are preceded by the prefix are part of the preset except for the anaglyph mode presets IO_Prst_Edit Here you can select which of the 8 selectable IO settings presets you want to edit Changing this will not change the active preset unless the currently active preset is the one you are going to edit All menu settings that are preceded by the prefix are part of the preset except for...

Страница 17: ...elected reference input The V Delay setting gives a delay in addition to the reference timing For example if the V Delay is set to 10 TV HD lines the output signal will be delayed by reference timing 10 TV HD lines The signal is delayed advanced with respect to the phase of the reference signal The available range is from 0 to a maximum of 1124 lines The default setting is 0ln F_delay F Delay sets...

Страница 18: ...e When it is set to Off it will pass the packet to the output as is only on Luminance In HD 1080i for ATC LTC transparency the user may switch it Off to pass the ATC LTC HANC packet on line 10 Output Matrix This setting will only work if S352_Insert is set to On It enables you to set the colorspace in REC709 default or REC2020 When set to either REC709 or REC2020 the S352 data is included in the s...

Страница 19: ...control range is between 128bits and 127 bits in steps of 1 bit The default setting is 0 bit 5 3 Network Setting Description IP_Conf0 With this setting you can either let the card obtain an IP address automatically via DHCP or assign an IP address manually By default this is set to DHCP mIP0 When IP_Conf0 is set to manual you can enter the preferred IP address here By default it is set to 0 0 0 0 ...

Страница 20: ...25 720p25 SD625 1080p24 720p24 SD525 1080p24sf NA IO Delay Displays the total delay in ms between the input and output Can be a value between 0ms and 13000 ms Ref Displays whether a correct reference is found Present or not NA 6 3 Net Status Item Description IP_Addr0 This item displays the status of the IP address It can be manual DHCP asking default DHCP Leased or DHCP Infin MAC0 This item displa...

Страница 21: ... changes on off 0 off other on Ref Status Reference can be selected between 0 255 0 no event 1 255 is the priority setting What Information is Available in an Event The message consists of the following items A message string to show what has happened in text for example INP_LOSS REF_LOSS INP_ RETURN A tag that also shows what happens but with a predefined number e g 1 loss of input 2 loss of refe...

Страница 22: ...ag Description Announcements 01hex Announcements on 81hex Announcements off Announcement of report and control values Ref Status 02hex REF_LOSS 82hex REF_RETURN Reference lost or returned Priority The priority is a user defined value The higher the priority of the alarm the higher this value will be Setting the priority to Zero disables the announcement of this alarm Alarms with priorities equal t...

Страница 23: ...dicates the presence of a valid SDI video signal on input 1 Reference LED Indicates the presence of a valid reference signal on the selected reference input connector ref 1 or ref 2 Connection LED This LED lights up after the card has initialized The LED lights up for 0 5 seconds every time a connection is made to the card INSTALLATION AND OPERATION MANUAL Synapse U4D100 8 LED Indication 15 ...

Страница 24: ...9 Block Schematic 16 November 2021 Issue 1 00 B ...

Страница 25: ...ft 3Gb s INPUT 2 top right 3Gb s PROCESSED OUTPUT 1 optional fiber out 3Gb s PROCESSED OUTPUT 2 optional fiber out GPI 3Gb s PROCESSED OUT 3 3Gb s PROCESSED OUT 4 3Gb s INPUT 3 lower left 3Gb s INPUT 4 lower right INSTALLATION AND OPERATION MANUAL Synapse U4D100 10 Connector Panels 17 ...

Страница 26: ...ll provide the source code on request either through physical distribution or electronic communication For physical distribution you may be charged a fee that covers distribution costs This offer is valid up to three years after date of purchase Please direct your request to the support department of EVS Broadcast Equipment SA EVS Broadcast Equipment SA supports open source software by participati...

Страница 27: ......

Страница 28: ......