31
DEPOLOX® 5 E flow cell
4. Installation
EN
Fig. 13 Cross-section, DFMe electronics mo-
dule
A Multi-Sensor
B
Sensor cable DFMe - DES for 3-electrode
measuring cell
C
LED glow stick
D pH sensor cable (optional)
E
Redox sensor cable (mV) (optional)
F
Housing of DFMe electronics module
G Mounting hook
H DFMe motherboard with measurement
input Cl
2
I
CAN extension socket (optional)
J
CAN connection socket to 700 P electronic
module or 700 M electronic module
4.16 Fitting the sens (optional)
Depending on requirements, insert or screw in
the sensors into the mount hole on the cover
of the cell body.
1 On the non-pressurized version, remove
the cap from the mounting hole on the
cell body cover.
2 On the pressurized version, unscrew the
protection cap.
3 Take the pH and redox combined measu-
ring and reference electrode out of the
KCl tank with stand.
4 With the conductivity sensor, remove the
blind plug and O-ring.
5 Insert or screw the prepared sensors into
the corresponding mounting hole in the
cell body cover.
A
B C D E
F
J
G
H
I
NOTICE
•
With the pressurized version, the sen-
sors must be screwed in or secured to
prevent them from being pushed out.
•
The membrane sensors, combined mea-
suring and reference electrodes and
electrodes must be prepared accor-
dingly. Please follow the appropriate ins-
tructions for the sensors!
•
Keep the KCl tank with stand for later
use or storage.
•
The pressurized version can be retrofit-
ted with the total chlorine membrane
sensor TC3 CAN (chapter 4.21.2).