DEPOLOX® Pool Compact
5. Installation
43
EN
5.11 Installing and connecting sen-
sors, LED glow stick and multi-
sensor
1 Remove the plug from the mount hole on
the cover of the cell body.
2 Remove the watering cap from the chlo-
rine sensor.
3 Screw the sensor into the mount hole (A)
in the cell body cover.
4 Remove the pH or ORP sensors from the
KCI tank with stand.
5 Screw them into the mount holes (C or E)
in the cell body cover.
6 Install the conductivity sensor (optional)
into the mount hole (B) and fix with clamp
connection.
7 Connect the sensors to the electronics
module with the pre-fitted cables. To do
this, feed the cables through the lower
hole (F) into the housing of the flow cell
and connect to the sensors as described
below:
•
Feed the LED glow stick through the
opening (F) and out of the housing
and screw it into the mount hole (D)
in the cell body cover.
•
Feed the multi-sensor (G) through
toward the left behind the cell body
and plug it into the flow control valve
(remove blind plug first).
•
Route sensor cables upward and out
of the housing through opening (F),
and connect the ‘free chlorine” sensor
cable with the chlorine sensor
•
The pH and ORP sensor cable connec-
tors with the pH and ORP sensors.
Fig. 7
View of top of housing cover
Fig. 8
Cross-section, flow cell
A Chlorine sensor (free chlorine)
B
Conductivity sensor
C
ORP (Redox) sensor
D LED glow stick
E
pH sensor
F
Housing opening for sensor cables (upper
bore hole)
G Multi-sensor
H Housing opening for sensor cables (lower
bore hole)
NOTICE
The sensors must be prepared accordingly.
Keep the watering cap of the chlorine sen-
sor and the transport container of the pH
and ORP sensors in a safe place for later use.
Please follow the relevant operating instruc-
tions for the sensors!