3

3.2 

FILLING THE FILTER MEDIA

3.2.1 

Before filling the filter media into the filter vessel, carry out a visual check of the laterals. 
Look for broken or loose laterals. Replace if necessary.

3.2.2 

To eliminate stress on the laterals, fill the filter vessel half full of water to provide a 
cushioning effect when the filter media is poured in.

3.2.3 

(a)  Top Mount Fibreglass Filters 

- Top Mount Fibreglass Filters are supplied with a 

perforated plastic locator, which centres the stem and prevents media from entering 
the stem pipe. Place the perforated plastic locator on the centre stem of the filter and 
carefully pour in the filter media via the perforated holes of the plastic locator. Remove 
the plastic locator once completed.

3.2.4 

Note: If a template is not provided or is lost, you must centre the stem and cover the 
stem opening to prevent non-alignment and media from entering the stem pipe.

3.2.5 

(b)  Side Mount Fibreglass Filters

 - Remove the top diffuser from the internal diffuser 

pipe and place the flexible air relief tube inside the filter vessel and to the side, out of the 
way. Cap the internal diffuser pipe with the filter media shield provided to prevent filter 
media from entering it. Do not move the diffuser pipe, as this can affect the integrity of 
the bulkhead seal.

3.2.6 

Note: The above instructions do not apply to Side Mount Fibreglass Filters larger than 
SM600 filters. Any filter media entering the diffusers will be removed during normal 
operation.

3.2.7 

Wash all the filter media and debris away from the threads and sealing surfaces of the 
filter vessel.

3.2.8 

Lubricate the o-ring or gasket on the Multiport Valve. The lubricant used should be 
silicon-based and not petrochemical-based.

3.2.9 

Thread the Multiport Valve or Top Cap onto the filter tank and hand tighten.

3.3 

PLUMBING

3.3.1 

Check that the incoming water pressure is within the filter’s recommended working 
pressure. Ensure that a pressure limiting valve is installed if using mains water or a 
high-pressure pump.

3.3.2 

Ensure that a foot valve/non-return valve is installed if the pump is installed at 500mm 
(20”) above the water level.

3.3.3 

If the filter is installed below the water level or connected to mains water, isolation 
valves should be installed at the inlet and outlet of the filter. This will prevent water 
flow during any routine maintenance.

3.3.4 

Minimise the length of pipe and the number of fittings to minimise restrictions to water 
flow.

3.3.5 

Connect all plumbing to the Multiport Valve, ensuring all plumbing connections are 
glued and tightened securely to prevent leaking.

3.3.6 

Ensure solvents/glues are not excessively applied to fittings as this could flow into 
o-rings and create sealing problems.

3.3.7 

Do not overtighten fittings or adapters.

Содержание EVOCLEAR E Series

Страница 1: ...ian Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty This manual contains important inform...

Страница 2: ...TABLE OF CONTENTS 1 0 FOREWORD 1 2 0 SAFETY 1 3 0 INSTALLATION 2 4 0 MULTIPORT VALVE OPERATION 4 5 0 INITIAL STARTUP OF FILTER 6 6 0 BACKWASHING 6 7 0 MAINTENANCE 8 8 0 TROUBLESHOOTING 9...

Страница 3: ...olution assumes no liability for the damage and injuries caused by unauthorised replacement parts and accessories 2 4 The user should make sure that the installation is carried out by qualified author...

Страница 4: ...onvenient and accessible for operation servicing and winterising 3 1 4 Ensure that the compliance label is facing the front to allow easy identification 3 1 5 The filter should be placed on a level co...

Страница 5: ...3 2 6 Note The above instructions do not apply to Side Mount Fibreglass Filters larger than SM600 filters Any filter media entering the diffusers will be removed during normal operation 3 2 7 Wash al...

Страница 6: ...oupling clamp half over the valve flange and the tank flange Insert the screws and nuts in the coupling clamp jaws ensuring that the nuts are located in the retainer slots on the clamp jaws Tighten th...

Страница 7: ...place and ensures any dirt or debris is rinsed out of the filter preventing dirt or debris from returning to the swimming pool spa Note The RINSE position is not available on 4 Way Multiport Valves 4...

Страница 8: ...filter mode 5 9 Adjust pool suction and return valves to achieve the desired flow Check the plumbing and filter for water leaks and tighten connections bolts and nuts as required 5 10 Record the press...

Страница 9: ...In the BACKWASH position water flow is automatically reversed through the filter so that it is directed to the bottom of the filter vessel and up through the filter bed flushing the previously trapped...

Страница 10: ...is a relationship between its pH total alkalinity calcium hardness and water temperature The water must be maintained at all times to the following pH 7 2 7 8 Total Alkalinity 80 150ppm Calcium Hardne...

Страница 11: ...bed and through the under drain Other restrictions including pool suction cleaners resistance from other inline equipment such as strainers Operating the filter on recirculate will determine if the re...

Страница 12: ...cated copyright in the content of this document is the property of Evolution Water and Lighting Solutions under Australian copyright law Unless otherwise indicated content may not be reproduced or tra...

Отзывы: