![Evolis PRIMACY 2 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/evolis/primacy-2/primacy-2_user-manual_2446724054.webp)
54
PRiMAcy 2
Print head cleaning
NOTE
Recommended cleaning cycle: every time the ribbon is changed.
Servicing accessory: cleaning swab impregnated with isopropyl alcohol.
To maintain the original print quality and to absorb surplus ink on the print head, we recommend that the print head is cleaned regularly using the
cotton buds supplied by Evolis. Protect the print head and its components from any discharge of static electricity.
!
Unplug the printer from its power supply before cleaning the print head.
Follow the cleaning cycles.
Avoid any contact between the print head and any metal or sharp objects. This could permanently damage the print head.
Avoid touching the print head directly with your fingers, as this could affect print quality or permanently damage the print head.
1
Take an Evolis cleaning
swab and press the
middle of the tube until
the end of the cotton
bud is impregnated
with alcohol.
2
Unplug the power supply, open the cover, and find the
print head.
3
Pull the protective cover
up and gently rub the
cotton bud from left
to right along the print
head for a few seconds.
4
close the cover.
Reconnect the printer.
NOTE
Wait for 2 minutes after cleaning before using your printer.