Страница 1: ...RC Model Jet Engines evoJet B90 B130vx B160vx 2005 2011 evoJet GmbH Am Parir 4A 52379 Langerwehe Germany Tel 49 2423 401163 Fax 401217 support evojet de http www evojet de...
Страница 2: ...cations 8 Installation Plan 9 Checklist for the First Operation 10 Checklist for Turning the Engine Off 10 EDT Status Display Engine Data Terminal 11 JETRONIC Vx Firmware Setup 13 1 INFO Menu 14 2 STA...
Страница 3: ...parate rechargeable lithium manganese battery which is used to power all system components such as fuel pump kerosene ignition valve etc State of the art precision CNC and laser cutting technology all...
Страница 4: ...about the legal regulations regarding such aircraft From a legal point of view a model aircraft is considered an aircraft like any other in most countries and is subject to the corresponding laws whic...
Страница 5: ...olding the model in place Furthermore the instructions by the R C system manufacturer must be followed closely Disclaimer evoJet cannot supervise the adherence to the assembly and operating instructio...
Страница 6: ...ries After the first installation and afterwards in regular intervals test the transmission range of your R C system with the jet engine running Before operating the engine remove all loose objects ne...
Страница 7: ...n Only use the full thrust of the jet engine for takeoff and for vertical climbing in aerobatics For limiting the airspeed we highly recommend using the optionally available Airspeed Sensor part no 81...
Страница 8: ...sor Alloy 2618 compressor 12 blade Turbine Axial wheel Inconel Fuel consumption B90 max 285 g 10 0 oz min B130 max 420 g 14 8 oz min B160 max 520 g 18 4 oz min Fuel type Jet A1 kerosene approved fuel...
Страница 9: ...evoJet B90 B130vx B160vx Instructions 4 0 Installation Plan 9...
Страница 10: ...ention to the correct charging program for the lithium manganese battery i e a maximum charging voltage of 12 6 V Use the 3s LiPo charging mode with 1 2 Amps Open the fuel tank ventilation then fill t...
Страница 11: ...ample for a standard start up procedure TH lock Remote control locked to unlock it pull the throttle and the trim all the way back See also 51 RC1 TRIM OFF page 25 TH stop Remote control unlocked engi...
Страница 12: ...nd the fuel supply system TH idle100 Thrust available to the pilot Ready for takeoff TH off To turn off the engine pull the throttle and the trim all the way back TH cool The engine enters a controlle...
Страница 13: ...the firmware parameters first press the SET key and then use the Up Down keys to switch between the available parameter sections To quit the SETUP menu and to return to the operating status display pr...
Страница 14: ...nd then use the Up Down keys to switch between the available parameters To quit the 1 INFO menu and to return to the SETUP menu press the SET key for more than 2 seconds ESC The operating status displ...
Страница 15: ...FUELPMP MAX has been reached The maximum pump voltage is a good indicator for the quality flow resistance of the entire fuel supply system An continuously increasing pump voltage after the flights may...
Страница 16: ...e startup procedure This is usually caused by air bubbles in the fuel supply system leading to a flameout in the combustion chamber Solution Make sure that the fuel supply is sufficient and uninterrup...
Страница 17: ...les and plugs higB An overvoltage of the turbine battery has been detected Solution Check the turbine battery connect the right battery type and or check the AUTOSTART 46 BATTERY battery type settings...
Страница 18: ...y and then use the Up Down keys to switch between the available parameters To quit the 2 STATISTICS menu and to return to the SETUP menu press the SET key for more than 2 seconds ESC The operating sta...
Страница 19: ...hows the total operating time of the jet engine resp the fuel pump Unit HH MM SS 24 JET ENGINE shows the identification serial number and lifetime of the connected jet engine Unit ID SERIAL LIFE B160...
Страница 20: ...SET key and then use the Up Down keys to switch between the available values A indicates the value to be set To finish the setting and store the new value press the SET key again To quit the 3 LIMITS...
Страница 21: ...5 RPM PEAK are reset 33 THROTTL UP This parameter specifies the acceleration throttle up time more thrust of the engine Recommend values B90 4 0 sec B130 B160 3 0 sec 34 THROTTL DOWN This parameter sp...
Страница 22: ...he SET key and then use the Up Down keys to switch between the available values A indicates the value to be set To finish the setting and store the new value press the SET key again To quit the 4 AUTO...
Страница 23: ...Standard value 16 seconds 44 HEAT UP This parameter specifies the time for the combustion chamber heating phase Standard value 3 seconds 45 GLOWPLUG This parameter specifies the voltage V for the glow...
Страница 24: ...the SET key and then use the Up Down keys to switch between the available values A indicates the value to be set To finish the setting and store the new value press the SET key again To quit the 5 R C...
Страница 25: ...ts For RC1 throttle the current throttle thrust setting is displayed NO no signal LOCK throttle and trim OFF 51 RC1 TRIM OFF or FAILSAFE detected FAIL throttle and trim are below the 51 RC1 TRIM OFF o...
Страница 26: ...only via RC1 throttle and trim SMOKE VALVE switching function for a smoker valve 5V 100mA connected to the AUXiliary port OFF 100 ON 100 For this set 59 AUX MODE to SMOKER VALVE The smoker function is...
Страница 27: ...ists after this time has elapsed the jet engine is switched off automatically Standard value 5 seconds 58 FAILS THROTTL Adjusting the thrust level in the case of an RC1 signal failure failsafe Standar...
Страница 28: ...on first press the SET key and then use the Up Down keys to test the individual system components devices A indicates the value to be set To finish the test press the SET key again To quit the 6 TEST...
Страница 29: ...ultaneous and take care not to flood the engine Standard value OFF 62 FUELVALVE Manual opening of the FUELvalve with the Up Down keys It must be connected to the left socket pins at the JETRONIC FUELv...
Страница 30: ...R C throttle CAUTION Please keep in mind that a stationary test run of the jet engine can lead to very high temperaures in the aircraft model exhaust duct due to the reduced airflow 67 JETRONIC OFF M...
Страница 31: ...tubing The measurement of the airspeed in flight allows several useful functions Determining the maximum airspeed km h see INFO 15 AIRSPEED PEAK Determining the covered total distance km flown see IN...
Страница 32: ...tion pressure possibly free or only on parts that are parallel to the incoming airflow Do not mount the tube on conical areas Keep a minimum distance of 2 5 cm 1 inch to a parallel surface For a more...
Страница 33: ...evoJet B90 B130vx B160vx Instructions 4 0 Notes 33...