Evo Control 17 & 25 Manual
3. Safety Instructions
•
Installation, repairs and maintenance of this unit must be performed by a qualified technician.
•
Any wiring must comply with local electrical regulations.
•
Ensure that the electrical supply corresponds to the specification indicated on the unit’s makers plate before
proceeding with the connection in accordance with the wiring diagram supplied.
•
The unit must be earthed to avoid any risk caused by insulation defects.
•
No wiring must come into contact with the heat source or the rotating fan parts.
•
The unit must be handled and lifted with appropriate equipment in correlation with the unit’s size and weight.
•
Electrical power must be switched off before any work is started on the unit.
•
Do not work on the electrical components if water or high humidity is present on site.
•
When the unit is being connected, ensure that no impurities are introduced into the pipework and water circuits.
A mesh filter must be provided on the hydraulic pump and in exchanger water inlets.
•
If the supply cord is damaged, it must be replaced by the manufacturer.
•
Do not expose the unit to or install near any flammable gases.
•
Ensure there is a circuit breaker for this unit.
•
The unit is equipped with an over-load protection system. After a previous stoppage, the unit will not start for at
least 3 minutes.
•
At the end of the unit’s useful life, the unit must be taken to a recycling centre appropriate for electronic devices
and not domestic waste.
•
Use supply wires suitable for 75°C
•
Caution: Single wall heat exchanger, not suitable for potable water connection.