EvoHeat CS-i Commercial Inverter Series Heat Pump 

3. Safety Instructions 

 

Installation, repair or relocations must be done by a fully qualified person and not by the customer. If done 

incorrectly it may cause fire, electric shock, water leakage and other hazards. 

 

Maintenance and operation must be carried out according to the recommended time and frequencies, as 

stated in this manual. 

 

To avoid risk of electrical shock, the unit must have a good power connection and earthing. 

 

If the supply cord is damaged, it must be replaced. 

 

Use genuine standard spare parts only. 

 

When an abnormality (smell of burning, etc.) occurs, stop the unit and disconnect the power or turn off the 

breaker. If the unit continues to be operated in an abnormal condition, it may cause a fire or hazards. 

 

Do not insert fingers or objects into the fans or evaporator of the unit. 

 

The unit is equipped with an over-load protection system. After a previous stoppage, the unit will not start 

for at least 3 minutes. 

 

For unit cleaning or maintenance, switch off and disconnect the power of the unit. 

 

Do not install the unit near flammable gas or spray flammable substances near it. 

 

Ensure the heat pump is installed on a strong and stable platform. 

 

A circuit breaker must be installed for the unit. 

 

Use supply wires suitable for 75°C 

 

The appliance must be fitted with means for disconnection from the supply mains having a contact 

separation in all poles that provides full disconnection under overvoltage category III conditions, these 

means must be incorporated in the fixed wiring in accordance with the wiring rules. 

 

An all-pole disconnection switch having a contact separation of at least 3mm in all poles should be 

connected in fixed wiring. 

 

Directive 2002/95/EC (RoHs): This product is compliant with directive 2002/95/EC (RoHs) concerning 

restrictions for the use of harmful substances in electric and electronic devices 

* Caution: Single wall heat exchanger, not suitable for potable water connection. 

 

Содержание CS-i Series

Страница 1: ......

Страница 2: ...Start up Shut Down ___________________________________________________________________ 9 5 2 2 Switching Modes Setting the Target Temperature ___________________________________________ 9 5 2 3 Clock...

Страница 3: ...130 Heat output at 27 C air 26 C water kW 65 130 Heat output at 15 C air 26 C water kW 50 100 Cooling output at 55 C air 35 C water kW 15 54 Cooling output at 45 C air 26 C water kW 30 73 C O P AT 27...

Страница 4: ...oHeat CS i Commercial Inverter Series Heat Pump 2 Unit Dimensions Evo CS i 65 unit mm Evo CS i 130 A L B W C H Water inlet outlet CS i 65 1750mm 830mm 1750mm 50 CS i 130 2260mm 1160mm 2127mm 100mm fla...

Страница 5: ...oad protection system After a previous stoppage the unit will not start for at least 3 minutes For unit cleaning or maintenance switch off and disconnect the power of the unit Do not install the unit...

Страница 6: ...on the front panel of the unit The gauge should be showing a pressure of approx 10 20 on the outside red band any less than this figure means there may be a leak in the refrigerant system and you shou...

Страница 7: ...nstalled a maximum of 5m below the water level of the pool spa If further than 5M please discuss with your EvoHeat specialist for the best advice Make sure the heat pump is not located where large amo...

Страница 8: ...in the air condenses on the fins of the evaporator During times of high humidity the condensate may be several litres per hour This may give the impression that the heater is leaking however this is a...

Страница 9: ...he unit to heat the pool or spa the filter pump must be running to circulate water through the heat exchanger After installation is completed follow the steps below 1 Turn on your filter pump Check fo...

Страница 10: ...perature interface 7 Temperature Curve Click to view the temperature and power curve 8 Water Inlet Temperature Press to enter mode setting and the target temperature interface 9 LOCK Click to lock the...

Страница 11: ...nction 1 Timing Start Button Start Green End Grey Click this button to start or end the timing start setting function 2 Timing On Setting Click to set the start time of the timer 3 Timing End Button O...

Страница 12: ...check the failure record the main interface will display a static The failure record is in reverse order according to the time of occurrence Press the clean key to delete all fault records 5 2 6 Colou...

Страница 13: ...eaners to ensure proper water flow Is the current pool spa water temperature higher than the set temperature on the controller If so the unit will not operate until the pool spa water temperature fall...

Страница 14: ...If the water has chlorine it is a water leak and you need to contact EvoHeat tech support on 1300 859 933 Or Turn the heater off and run the water pump continuously for a period of 2 4 hours If the wa...

Страница 15: ...rcuit Flow Switch Prot E03 No water little water in water system Check the pipe water flow and water pump Waterway Anti freezing Prot E05 Water temp or ambient temp is too low Inlet and outlet temp to...

Страница 16: ...eck the input voltage measurement Inv Sampling Volt F11 The input voltage sampling fault Check and adjust the current measurement Comm Err DSP PFC F12 DSP and PFC connect fault Check the communication...

Страница 17: ...101 123A 2 x 35mm2 35mm2 160A 30mA less than 0 1 sec 123 148A 2 x 50mm2 50mm2 225A 30mA less than 0 1 sec 148 186A 2 x 70mm2 70mm2 250A 30mA less than 0 1 sec 186 224A 2 x 95mm2 95mm2 280A 30mA less t...

Страница 18: ...17 EvoHeat CS i Commercial Inverter Series Heat Pump 7 3 Wiring Diagrams 7 3 1 CS i 65...

Страница 19: ...18 EvoHeat CS i Commercial Inverter Series Heat Pump 7 3 2 CS i 130...

Страница 20: ...rature input 13 AI DI06 Water input temperature input 14 AI DI07 Water output temperature input 15 AI DI08 System fan coil temperature input 16 AI DI09 Ambient temperature input 17 AI DI10 Mode switch...

Страница 21: ...time 8 1 Energy Saving Tips If your pool water is allowed to cool significantly it may take several days to return to the desired swimming temperature For weekend use it is more economical to maintai...

Страница 22: ...y handling freighting or damage to the product in transit 4 If warranty service is required you should a contact Evo Industries Australia on 1300 859 933 or via our Contact page on our web site b prov...

Отзывы: