background image

Hydrogen Sulfide Transmitter

E2615-H

2

S

User Manual

Содержание E2615-H2S

Страница 1: ...Hydrogen Sulfide Transmitter E2615 H2S User Manual...

Страница 2: ...5 Product description 6 Safety requirements 6 Operating conditions 6 Installation guidelines 6 Mounting dimensions 8 Electrical connections 9 Operation 10 Maintenance 10 Calibration 10 Delivery set 1...

Страница 3: ...described as sweet or sickeningly sweet Odor threshold 0 01 1 5 ppm Note Sense of smell becomes rapidly fatigued and can NOT be relied upon to warn of the continuous presence of H2S Hazards Highly fl...

Страница 4: ...plastic wall mount protection class IP65 Indoor enclosure White ivory or black ABS plastic wall mount protection class IP20 Dimensions IP65 H70 W80 D36 mm IP20 H71 W71 D27 mm CE marking According to...

Страница 5: ...voids the warranty Do not touch the electronic components directly as they are sensitive to static electricity Connection diagrams can be found in the electrical connections section The device might n...

Страница 6: ...ance calibration The aforementioned conditions above will affect the coverage area of the device However the coverage area for a transmitter is usually between 2 5 to 5 meters radius For early leakage...

Страница 7: ...th a hydrophobic microporous PTFE filter to protect the sensor from dust dirt and water drops NOTE Never stab or press the filter near its center where the sensor is located since this may damage the...

Страница 8: ...f wires with a cross section of 0 2 1 5 mm2 We recommend to strip the wire end by 8 9 mm and use wire end sleeves To connect the wire loosen the screw insert the wire end into the terminal hole and ti...

Страница 9: ...the screws The device is ready to use Maintenance Do not perform any maintenance operation with the power on Clean the device with a soft damp cloth Do not use any abrasive cleaning agents Do not imm...

Страница 10: ...24 08 2022 Delivery set Transmitter E2615 Mounting accessories 2 screws with plastic dowels Order code for E2615 H2S options E2615 options Order code IP20 enclosure E2615 H2S IP20 IP65 enclosure E261...

Страница 11: ...Manufacturer will at its option either repair or replace a product that proves to be defective This warranty is void if the product has been operated in conditions outside ranges specified by the Man...