EQX–IP18-IPG
EQX Input and IP Gateway Module
Page - 42
Revision 1.0
7.15. NOTIFY
Notify tab allows the user to enable or disable the DIN
SDI Input Present
traps and
Fan Notify
traps
with monitoring.
Figure 7-28: Notify Tab
7.15.1. SDI Input Notify
SDI Input 1 to 18 Present
•
When set True; a fault condition triggered by a missing DIN SDI Input will send a trap
message to the trap addresses configured in the Trap Control section of the System tab.
SDI Input Faults
•
This field will display green when there is no fault and red for a fault indication
7.15.2. Fan Notify
Board Over Heat Present
•
When set True; if the board temperature exceeds the threshold limit that is set in the
System
tab, a trap message will be sent to the trap addresses configured in the Trap Control section
of the System tab.
CPU Over Heat Present