Model 8010TM SDI Time Code Master Manual
Page 3-34
Revision 1.5.1
OPERATION
GPO1 ASSIGNMENT
The following descriptions indicate how the GPO will function with each
setting.
Rdr event
The output will activate for the
GPO Duration
when the
reader time matches the REVT register and the event register is
armed. See section 3.7.9.5 for information about setting the
REVT register and arming it.
Gen event
The output will activate for the
GPO Duration
when the
generator time matches the GEVT register and the event
register is armed. See section 3.7.9.5 for information about
setting the GEVT register and arming it.
1 pulse/sec
The output will activate for the
GPO Duration
at the
beginning of each second of the generator time. The
GPO
Duration
value such that the pulse is less than one half a second
long.
1 pulse/min
The output will activate for the
GPO Duration
at the
beginning of each minute of the generator time.
Ref failure
The output will activate when a proper Gen Lock video
reference is missing.
T
he output will remain active until the Gen
Lock video returns.
Gpo1 = rdr event
Gpo1 = gen event
Gpo1 = 1 pulse/sec
Gpo1 = 1 pulse/min
Gpo1 = ref failure
3.7.9.4. Adjusting the General Purpose Output Duration
GPO DURATION
The
GPO DURATION
menu item is used to adjust the duration (in
frames) of both of the general purpose outputs. Use the
OR
keys
to change the duration. Note that when the
GPO ASSIGNMENT
is set
to
Ref failure
the respective output will remain low until the Gen Lock
video returns.
Gpo duration 01
3.7.9.5. Setting the Time of the Event Registers
When one of the GPO assignments is set to
GEN EVENT
the output activates based on the time
entered into the GEVT register. When one of the GPO assignments is set to
RDR EVENT
the output
activates based on the time entered into the REVT register.
To access the GEVT and REVT registers press the
SHIFT+DISPLAY
buttons one or more times until
the display prompt is
GEVT
or
REVT
. The
ENTER
and
CLEAR
keys are used in conjunction with the
numeric keys to set the value stored in the event registers. Enter a valid time into the desired register
following the same method used to enter the generator time. The event register may then be 'armed' as
follows:
Содержание 8010TM
Страница 2: ...This page left intentionally blank ...
Страница 6: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 12: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 18: ...Model 8010TM SDI Time Code Master Manual Page 1 6 Revision 1 5 1 OVERVIEW This page left intentionally blank ...
Страница 20: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 30: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 68: ...Model 8010TM SDI Time Code Master Manual Page 3 38 Revision 1 5 1 OPERATION This page left intentionally blank ...
Страница 70: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...
Страница 88: ...Model 8010TM SDI Time Code Master Manual Revision 1 5 1 This page left intentionally blank ...