background image

7700FR/7800FR MultiFrame

 

7800TR-32x24 Modular Tally Router 

 

 

 

Revision 1.2 

Page -

 

i

 

 

TABLE OF CONTENTS 

 

1

 

OVERVIEW ................................................................................................................................... 1

 

2

 

SPECIFICATIONS......................................................................................................................... 3

 

2.1

 

REAR GENERAL PURPOSE INPUTS ................................................................................. 3

 

2.2

 

REAR GENERAL PURPOSE OUTPUTS ............................................................................. 3

 

2.3

 

ETHERNET PORT ................................................................................................................ 3

 

2.4

 

ELECTRICAL ....................................................................................................................... 3

 

2.5

 

PHYSICAL............................................................................................................................ 3

 

3

 

INSTALLATION ............................................................................................................................ 5

 

3.1

 

REAR PANEL ....................................................................................................................... 5

 

3.2

 

ETHERNET CONNECTION .................................................................................................. 6

 

3.3

 

CARD EDGE ........................................................................................................................ 7

 

3.3.1

 

LED Indicators ........................................................................................................... 7

 

3.3.2

 

Card Edge Serial Port ............................................................................................... 8

 

3.3.3

 

Frame Status LEDs ................................................................................................... 9

 

3.3.4

 

LED Display ............................................................................................................... 9

 

3.4

 

REAR GENERAL PURPOSE INPUTS/OUTPUTS ............................................................. 11

 

3.5

 

GENERAL PURPOSE INPUTS .......................................................................................... 13

 

3.6

 

GENERAL PURPOSE OUTPUTS ...................................................................................... 14

 

3.7

 

WET POWER ..................................................................................................................... 15

 

3.8

 

GENERAL PURPOSE I/O MODES .................................................................................... 16

 

3.8.1

 

Tally Wet and Dry Terminology ............................................................................... 16

 

3.8.2

 

General Purpose Output Modes .............................................................................. 17

 

3.8.3

 

General Purpose Input Modes ................................................................................. 17

 

3.9

 

OPTIONAL 7800TR-BHP BULKHEAD PANEL .................................................................. 17

 

3.9.1

 

7800TR-BHP General Purpose Output Connections ............................................... 18

 

3.9.2

 

7800TR-BHP General Purpose Input Connections .................................................. 19

 

4

 

CONFIGURATION ...................................................................................................................... 20

 

4.1

 

SETTING THE IP ADDRESS .............................................................................................. 20

 

4.2

 

UPDATING AND USING VISTALINK PRO ........................................................................ 21

 

4.2.1

 

Updating VistaLINK® with a New JAR File .............................................................. 22

 

4.2.2

 

Applying a JAR update Vista

LINK

® Pro .................................................................. 23

 

4.2.3

 

Opening the Configuration View for the 7800TR-32X24 in Vista

LINK

® Pro ............ 23

 

4.2.4

 

Opening the Alarm View for the 7800TR-32X24 in Vista

LINK

® Pro ........................ 24

 

4.3

 

CONFIGURING THE TALLY ROUTER .............................................................................. 24

 

4.3.1

 

Selecting the Wet Voltage Source ........................................................................... 24

 

4.3.2

 

Configuring the GPI ................................................................................................. 25

 

Содержание 7800TR

Страница 1: ...WER 15 3 8 GENERAL PURPOSE I O MODES 16 3 8 1 Tally Wet and Dry Terminology 16 3 8 2 General Purpose Output Modes 17 3 8 3 General Purpose Input Modes 17 3 9 OPTIONAL 7800TR BHP BULKHEAD PANEL 17 3 9 1 7800TR BHP General Purpose Output Connections 18 3 9 2 7800TR BHP General Purpose Input Connections 19 4 CONFIGURATION 20 4 1 SETTING THE IP ADDRESS 20 4 2 UPDATING AND USING VISTALINK PRO 21 4 2 1 ...

Страница 2: ...head Panel 18 Figure 3 8 7800TR BHP GPO in Wet Mode Circuit Diagram 18 Figure 3 9 7800TR BHP GPO in Dry Mode Circuit Diagram 19 Figure 3 10 7800TR BHP GPI in Wet Mode Circuit Diagram 19 Figure 3 11 7800TR BHP GPI in Dry Mode Circuit Diagram 19 Figure 4 1 VistaLINK Pro Version Information 22 Figure 4 2 VistaLINK Pro Configuration View 23 Figure 4 3 VistaLINK Pro GPI Settings Tab 25 Figure 4 4 Vista...

Страница 3: ... of future performance either expressed or implied The only warranty offered by Evertz in relation to this product is the Evertz standard limited warranty stated in the sales contract or order confirmation form Although every attempt has been made to accurately describe the features installation and operation of this product in this manual no warranty is granted nor liability assumed in relation t...

Страница 4: ...7700FR 7800FR MultiFrame 7800TR 32x24 Modular Tally Router Page iv Revision 1 2 This page left intentionally blank ...

Страница 5: ... on both of the rear 62 pin D Sub connectors This can be used to power passive devices tally lights buttons buzzers etc and to simplify wiring to GPIs and GPOs The wet power can be configured to come from either a 5V or 12V internal power source The MAGNUM control system with the MAGNUM TALLY software module integrates the GPI and GPO from the Tally Router into a single unified interface The GPI a...

Страница 6: ...uts are protected by optoisolators Wide voltage range up to 24V General Purpose Outputs are protected by polyfuses Can configure General Purpose Inputs for edge high or low triggering Can configure General Purpose Outputs as pulse or steady outputs All General Purpose I O can be setup as normal normally open or inverted normally closed Available 7800TR BHP bulkhead panel to breakout rear GPIO Giga...

Страница 7: ... isolated from chassis ground Timing GPO relay closure upon receipt of SA Quartz protocol command 2ms 2 3 ETHERNET PORT Network Type Gigabit Ethernet 1000Base T IEEE 802 3z Connector RJ 45 SNMP Standard SNMP v1 compliant RFC 1157 RFC 1213 2 4 ELECTRICAL Voltage 12V DC Power Consumption Wet Power Off 10 watts typical Wet power not being used Wet Power On 50 watts max internal 5V or 12V power being ...

Страница 8: ...7700FR 7800FR MultiFrame 7800TR 32x24 Modular Tally Router Page 4 Revision 1 2 This page left intentionally blank ...

Страница 9: ...eral purpose inputs and wet voltage There is also a gigabit Ethernet jack for configuration and control Install the rear plate onto the rear of the multiframe in a free location of your choice Secure the rear plate using the four provided M2 5 x 8mm screws Take note of the two slot numbers the rear plate occupies Figure 3 1 7800TR 32x24 Rear Plate A ribbon cable joins the two boards inside the rea...

Страница 10: ...ional wiring guide information 1 2 3 4 5 6 7 8 Pin EIA TIA 568A AT T 258A or EIA TIA 568B 100Base TX 1000Base T 1 White Green stripe White Orange stripe Transmit TxRx A 2 Green Orange Transmit TxRx A 3 White Orange stripe White Green stripe Receive TxRx B 4 Blue Blue Not Used required TxRx C 5 White Blue stripe White Blue stripe Not Used required TxRx C 6 Orange Green Receive TxRx B 7 White Brown ...

Страница 11: ...thernet LD7 Power Good LD10 FPGA Done LD5 Always Off LD4 Always Off LD3 Always Off LD2 Always Off Figure 3 2 Card Edge LEDs and Serial Port 3 3 1 LED Indicators Most of the small LED indicators are currently reserved for factory use LD7 indicates the power status of the card This LED should always be illuminated Green If it is off this indicates a problem with the power supply of the card LD10 sho...

Страница 12: ...on PC End RS 232 2 row x 3 pin Berg Pin 9 pin D Sub Female Pin Reserved 1 Brown KEY 2 Red Ground 3 Orange Ground 5 Rx 4 Yellow Tx 3 Tx 5 Green Rx 2 KEY 6 Blue Table 3 2 7700 Upgrade Cable Wiring WA S76 Connect the rectangular 3x2 pin connector of the WA S76 cable to the card edge connector J8 The connector is keyed so that it will only go on one way Connect the 9 pin female D Sub connector to a CO...

Страница 13: ...a serial software upgrade Table 3 4 Command Line Interface Commands 3 3 3 Frame Status LEDs These two LEDs indicate the overall health of the card During normal operation the Green LED will be on and the Red LED will be off If the Green LED is off or the Red LED is on this indicates a problem with the card This fault condition can trigger the global frame status if jumper J15 is placed in the FAUL...

Страница 14: ...7700FR 7800FR MultiFrame 7800TR 32x24 Modular Tally Router Page 10 Revision 1 2 This page left intentionally blank ...

Страница 15: ... GPO 4B GPO 7A GPO 7B GPO 10A GPO 10B GPO 13A GPO 13B GPO 16A GND WET GPI 2 GPI 2 GPI 5 GPI 5 GPI 8 GPI 8 GPI 11 GPO 2A GPI 11 GPO 2B GPO 5A GPO 5B GPO 8A GPO 8B GPO 11A GPO 11B GPO 14A GPO 14B GPO 16B GND WET GPI 3 GPI 3 GPI 6 GPI 6 GPI 9 GPI 9 GPI 12 GPO 3A GPI 12 GPO 3B GPO 6A GPO 6B GPO 9A GPO 9B GPO 12A GPO 12B GPO 15A GPO 15B GND WET 21 20 19 18 17 16 15 14 9 8 7 6 5 4 3 2 13 12 11 10 1 42 4...

Страница 16: ...7 6 5 4 3 2 13 12 11 10 1 42 41 40 39 38 37 36 35 30 29 28 27 26 25 24 23 34 33 32 31 22 62 61 60 59 58 57 56 55 50 49 48 47 46 45 44 43 54 53 52 51 GPI 13 GPI 13 GPI 16 GPI 16 GPI 19 GPI 19 GPI 22 GPO 17A GPI 22 GPO 17B GPO 20A GPO 20B GPO 23A GPO 23B GPO 26A GPO 26B GPO 29A GPO 29B GPO 32A GND WET GPI 14 GPI 14 GPI 17 GPI 17 GPI 20 GPI 20 GPI 23 GPO 18A GPI 23 GPO 18B GPO 21A GPO 21B GPO 24A GPO...

Страница 17: ...ptoisolator The optoisolator is used to protect the tally router s internal circuitry and also to isolate the GPIs from each other If more than 24 volts is applied to a GPI it may become damaged but the damage will be isolated to the particular GPI The selected Wet Power source is available on three pins of each D Sub connector as WET and GND This wet power can be used to wire the GPIs as Dry Plea...

Страница 18: ...ve current with a polyfuse Polyfuses operate by means of thermal limiting The maximum allowable current is shown in Table 3 6 If excessive current is applied to the GPO the polyfuse will heat up and open This process happens very quickly if the current is high but may take hours if the current is only a little above the maximum When the polyfuse opens it immediately begins to cool and will eventua...

Страница 19: ...to WET The GND pins act as the return chassis ground Table 3 7 Wet Power Source Selections The wet power source WET is protected by a 1 5 Amp polyfuse no matter which voltage source is selected Care must be taken to limit the cumulative WET current draw out of the rear D Sub connectors to 1 5 Amps or less If more current than the maximum is drawn to the WET voltage polyfuse will heat up and open T...

Страница 20: ...rate This terminology is arcane and confusing outside its narrow scope of usage The term Wet means that voltage is present and Dry means no voltage always from the perspective of the output port General Purpose Output When connecting a GPO to a GPI remember Wet to Wet and Dry to Dry Never connect Wet to Dry or vice versa A General Purpose Output has two contacts marked A and B A Dry GPO opens thes...

Страница 21: ...rpose Input Modes The default state of GPIs is normally open mode with edge triggering disabled When a GPI is not activated it reports that it is Off While a GPI is activated by an external voltage source it reports that it is On The GPI reports the level that is applied to its inputs Each GPI can be individually set to have edge triggering enabled When in edge triggering mode the GPI turns on and...

Страница 22: ... DRY WET 13 DRY WET 14 DRY WET 15 DRY WET 16 DRY WET 17 DRY WET 18 DRY WET 19 DRY WET 20 DRY WET 21 DRY WET 22 DRY WET 23 DRY WET 24 TR4800 BHP WET PWR SN Figure 3 7 Optional 7800TR BHP Bulkhead Panel When connecting the rear D Sub cables be careful to connect the correct cable to the ports on the rear of the 7800TR BHP 3 9 1 7800TR BHP General Purpose Output Connections The rear 32 General Purpos...

Страница 23: ...lly router are broken out to 24 terminal blocks across the bottom of the bulkhead panel Each GPO has a miniature slide switch below it to select between Wet and Dry modes see section 3 8 1 The circuit diagrams for the GPIs in both modes are shown in Figure 3 10 and Figure 3 11 GPI GPI 10 mA 1 4 V WET GPI 1 2 optoisolator Figure 3 10 7800TR BHP GPI in Wet Mode Circuit Diagram 10 mA WET DRY GPI 1 2 ...

Страница 24: ...ly inserted into the frame and powered up 5 Press ENTER in the terminal and the CLI command line interface prompt should appear The IP address of the unit can be set with the ifconfig command The general format of the command is shown as follows ifconfig 0 inet IP netmask SUBNETMASK broadcast BROADCAST gateway GATEWAY Assign an unused IP address that is compatible with your network s addressing sc...

Страница 25: ...attention Evertz offers VistaLINK Pro a powerful software suite for SNMP monitoring and control suitable for management of both small and large systems The VistaLINK Pro client is a powerful SNMP client that is offered as a free download from the Evertz website www evertz com It can be used for monitoring and configuring Evertz gear The full version of VistaLINK provides a server application for c...

Страница 26: ...pen the VistaLINK Pro client and select the Tools menu go to Products and select the Version Information menu item It is critical that the JAR version used is matched to the firmware version of the unit otherwise some controls may not operate properly All JAR updates are available on the Evertz website www evertz com The 7800TR 32X24 is listed under the Routers section Figure 4 1 VistaLINK Pro Ver...

Страница 27: ...ct any 7800TR 32X24 units connected to the network during the next discovery Open the Tree menu and select Refresh to perform a network discovery immediately Discovered devices are displayed on the left side of the screen in the Navigation Tree under the Hardware node If the navigation tree is not visible check that it has not been hidden by opening the Tree menu and selecting Hide Show Tree If th...

Страница 28: ...ed the flashing will change to a green color To clear the fault it must be acknowledged by clicking the button in the Ack column 4 3 CONFIGURING THE TALLY ROUTER The 7800TR 32X24 tally router is configured through SNMP using the VistaLINK Pro software The various configuration tabs are listen in Table 4 1 Each of the screens and the configuration options are discussed in the following sections Tab...

Страница 29: ...he current state of the selected GPI Figure 4 3 VistaLINK Pro GPI Settings Tab 4 3 3 Configuring the GPO There are a total of 32 GPOs on the rear plate of the unit that are configured in the Rear GPO Settings tab The GPO to be configured 1 32 is first select the Select GPO control Once the GPO is selected any changes below will affect that GPO only There are 4 controls that are used to configure t...

Страница 30: ...note AN65 for detail on the format of the Quartz protocol The Quartz protocol control can be done through the Serial2 port or more commonly through a TCP IP connection The MAGNUM control software uses Quartz protocol to integrate the tally inputs and outputs into a broader infrastructure control system The Tally Router Quartz over IP port is 9676 Upon connection the tally router will automatically...

Страница 31: ...n The General Purpose Outputs are mapped to level A destinations 1 32 The GPOs can be turned on by routing them to source 2 For example the command SA027 002 will turn on GPO 27 The tally router will respond with a UA027 002 to acknowledge the GPO has been changed The command SA027 001 with turn off GPO 27 causing a response of UA027 001 ...

Страница 32: ...e and password The default user name is admin with password admin 5 2 1 MAGNUM TALLY License In addition to the normal MAGNUM license the optional MAGNUM TALLY license is required to allow MAGNUM to work with tally routers Click the ADMIN button and select License Management The minimum required licensed modules to use Magnum with Tally Routers are Magnum Router Magnum Tally Magnum Multiviewer Fig...

Страница 33: ...the Tally Router must be added as a TR3200E Magnum uses the same control protocol for both the TR 3200E and the 7800TR 32X24 products The only difference is the number of GPI and GPO available The 7800TR 32X24 should be configured with 24 inputs and 32 outputs Enter the IP address of the tally router for the Primary IP Make sure to use port 9676 Repeat this for every tally router in your system Cl...

Страница 34: ...ton to make changes to the Tally Grid The Tally Router devices will appear under the GPI O tab on the right side of the screen The Tally Router sources SRC are GPIs and the tally router destinations DST are GPOs All the configured router sources and destinations are shown as well It is easy to map a router source change to a tally router destination GPO activation Once changes have been made to th...

Страница 35: ...irmware Upgrade with VistaLINK Pro The upgrade is performed through the version information dialog see section 4 2 1 This dialog also displays the current firmware version of the unit Access this dialog in the VistaLINK Pro client by going to the Tools menu Products and selecting Version Information Select the Active filter and click on the TR7700 There is an Upgrade checkbox that should be checke...

Страница 36: ...he PPCBOOT prompt Type the command upgrade and press ENTER You should see the message upload product firmware now The firmware can now be sent to the tally router using the XMODEM protocol checksum mode This should take about 4 minutes to complete When the firmware is finished sending you should see the message upload okay At this point enter the command boot and press ENTER The tally router will ...

Отзывы: