7700 MultiFrame Manual
7707VAT Digital Video and AES Audio Fiber Transmitter
Revision
2.3
Page-25
8.4. V
ISTA
LINK
®
FAULT STATUS PARAMETERS – TRAPS
The following parameters can be remotely monitored through the VistaLINK
®
interface as trap statuses in
the Configuration View and traps in the Alarm View.
Parameter Description
AES audio signal 1
Indicates whether AES 1 signal is present or not. Loss of AES
1 will trigger the “No AES 1” trap in the VistaLINK Alarm View.
AES audio signal 1
Indicates whether AES 2 signal is present or not. Loss of AES
1 will trigger the “No AES 2” trap in the VistaLINK Alarm View.
Carrier weak
Indicates whether input video signal is weak or not. When
signal becomes weak it will trigger the “Carrier Strength Weak”
trap in the VistaLINK Alarm View.
EDH error
Indicates there are EDH errors present in input video signal.
The EDH Error will trigger the “EDH Error Present” trap in the
VistaLINK Alarm View.
Laser OK
Indicates whether laser is in good condition or not. If there is a
laser fault it will trigger the “Laser Not OK” trap in the VistaLINK
Alarm View.
Module OK
Indicates whether card is in good operating condition or not. If
there is a module fault fault it will trigger the “Module Fault
Alert” trap in the VistaLINK Alarm View.
Signal present
Indicates if there’s valid video signal present at the input. Loss
of valid video signal will trigger the “Signal Not Present” trap in
the VistaLINK Alarm View.
Not In Local Control Mode
(trap only)
This trap in VistaLINK Alarm View triggers every time card is
switched to Remote mode.
Local Control Mode
(trap only)
This trap in VistaLINK Alarm View triggers every time card is
switched to Local mode.
Not In remote Control Mode
(trap only)
This trap in VistaLINK Alarm View triggers every time card is
switched to Local mode.
Remote Control Mode
(trap only)
This trap in VistaLINK Alarm View triggers every time card is
switched to Remote mode.
Table 8-4: 7707VAT and 7707VAT-U VistaLINK
®
Fault Status Parameters – Traps