Model 5010 Time Code Master Manual
Page 4-38
Revision
3.1.1
OPERATING
INSTRUCTIONS
4.9.
PARALLEL REMOTE CONTROL FUNCTIONS
A 9 pin D connector located on the rear panel labeled REMOTE CTL provides 6 parallel control inputs
for remote control of some of the model 5010 functions. The pinout of the D connector is as follows:
Pin
Description
1 Frame
Ground
6
LTC reader enable
2 VCG
On/Off
7
VITC reader enable/(6Hz ref)
3
Jam Sync enable
8
Time - UB Transfer enable
4
UB - UB Transfer enable
9 Output
1
5 Output
2
4.9.1. Parallel Remote Control Input Functions
LTC RDR:
Provides an alternate method of selecting the LTC reader. The LTC reader is selected
by a high to low transition on this input, and deselected by a low to high transition.
VITC RDR:
Provides an alternate method of selecting the VITC reader on the 5010-VITC and 5010-
VITC-24. The VITC reader is selected by a high to low transition on this input, and
deselected by a low to high transition.
"
When both the LTC RDR and VITC RDR inputs are the same, (either both grounded,
or both open), the AUTO mode of the reader is selected.
VCG ENABLE:
Provides an alternate method of turning the character inserter generator
On and Off. The character inserter is turned On by a high to low transition on this input,
and turned Off by a low to high transition.
JAM SYNC ENABLE:
Provides an alternate method of turning the Continuous Jam Sync mode
On and Off. Jam Sync is turned On by a high to low transition on this input, and turned
Off by a low to high transition. Momentarily closing this input to ground and releasing it
will perform momentary jam sync.
TIME-UB TRANSFER ENABLE:
Provides an alternate method of turning the Reader Time to
Generator User Bit transfer function On and Off. Time to User Bit transfer is turned On
by a high to low transition on this input, and turned Off by a low to high transition.
UB-UB TRANSFER ENABLE:
Provides an alternate method of turning the Reader User Bit to
Generator User Bit transfer function On and Off. User Bit to User Bit transfer is turned
On by a high to low transition on this input, and turned Off by a low to high transition.
Содержание 5010
Страница 2: ...This page left intentionally blank ...
Страница 6: ...Model 5010 Time Code Master Manual Revision 3 1 1 REVISION HISTORY This page left intentionally blank ...
Страница 12: ...Model 5010 Time Code Master Manual Page vi Revision 3 1 1 TABLE OF CONTENTS This page left intentionally blank ...
Страница 14: ...Model 5010 Time Code Master Manual Revision 3 1 1 OVERVIEW This page left intentionally blank ...
Страница 20: ...Model 5010 Time Code Master Manual Page 1 6 Revision 3 1 1 OVERVIEW This page left intentionally blank ...
Страница 22: ...Model 5010 Time Code Master Manual Revision 3 1 1 INSTALLATION This page left intentionally blank ...
Страница 30: ...Model 5010 Time Code Master Manual Revision 3 1 1 TECHNICAL SPECIFICATIONS This page left intentionally blank ...
Страница 96: ...Model 5010 Time Code Master Manual Revision 3 1 1 TECHNICAL DESCRIPTION This page left intentionally blank ...
Страница 106: ...Model 5010 Time Code Master Manual Page 6 10 Revision 3 1 1 TECHNICAL DESCRIPTION This page left intentionally blank ...