Model 5010 Time Code Master Manual
Page 4-30
Revision
3.1.1
OPERATING
INSTRUCTIONS
Select
SPECIAL
to read VITC data which was encoded with special KEYKODE CRC encoding by a
4025 set to one of its ‘full KeyKode’ modes. Normally this mode is only used when the reader mode is
set to DATA DATA.
4.6.5. Controlling the Reader ‘Look ahead’ Compensation
The
DISPLAY
menu item is used to select whether the normal 'look ahead' compensation for reader
dropouts is active or not. Normally, the data is read in one frame and displayed with an 'add 1 frame'
compensation. This method guarantees an 'on time' character display for LTC and also helps to cover
any minor reader disturbances. In some operational modes it is desirable to disable this feature and to
display exactly what is being read. When reading VITC, it is possible to read and display the
information in the same video field, thus maintaining field accuracy even in DIRECT mode. The
topmost positions of the character generator are not available when in the direct mode.
Select
PROCESSED
to enable normal 'look ahead' compensation. Displays from either the LTC or
VITC readers will be 'on time' but will
NOT
follow code discontinuities immediately.
Select
DIRECT
to enable DIRECT display mode. Data is displayed exactly as it is read without 'look
ahead' compensation. Displays from the VITC reader will be 'on time' but cannot be positioned at the
very top of the raster. Displays from the LTC reader will be behind by two frames.
4.6.6. Configuring Whether the Reader will Display Local Time
or UTC Time in the Time/Date Mode
When the RDR MODE is set to TIME DATE, the
TIME ZONE ADJ
menu item of the READER menu is
used to select whether the Reader will display the time as UTC or UTC adjusted by the programmed
Time Zone Offset (Local Time).
UTC:
Configures the reader to display the time as UTC. The Reader will display the
time and date information exactly as it is encoded.
LOCAL TIME:
Configures the reader to display the time as Local Time. The Reader will display
the time and date information adjusted for the time zone that is encoded into the
user bits.
DISPLAY
PROCESSED
DIRECT
TIME ZONE ADJ
UTC
LOCAL TIME
Содержание 5010
Страница 2: ...This page left intentionally blank ...
Страница 6: ...Model 5010 Time Code Master Manual Revision 3 1 1 REVISION HISTORY This page left intentionally blank ...
Страница 12: ...Model 5010 Time Code Master Manual Page vi Revision 3 1 1 TABLE OF CONTENTS This page left intentionally blank ...
Страница 14: ...Model 5010 Time Code Master Manual Revision 3 1 1 OVERVIEW This page left intentionally blank ...
Страница 20: ...Model 5010 Time Code Master Manual Page 1 6 Revision 3 1 1 OVERVIEW This page left intentionally blank ...
Страница 22: ...Model 5010 Time Code Master Manual Revision 3 1 1 INSTALLATION This page left intentionally blank ...
Страница 30: ...Model 5010 Time Code Master Manual Revision 3 1 1 TECHNICAL SPECIFICATIONS This page left intentionally blank ...
Страница 96: ...Model 5010 Time Code Master Manual Revision 3 1 1 TECHNICAL DESCRIPTION This page left intentionally blank ...
Страница 106: ...Model 5010 Time Code Master Manual Page 6 10 Revision 3 1 1 TECHNICAL DESCRIPTION This page left intentionally blank ...