3505FR Series Fiber Optic SFP Frame
CONFIGURATION AND CONTROL
Revision 1.2
Page - 33
5.
CONFIGURATION AND CONTROL
The 3505FR series frames are capable of supporting two (main and redundant) 3505FC Frame
Controller cards to provide a single point of access to communicate with the VistaLINK
®
enabled
3505FR. Each 3505FC provides a 10Base-T/100Base-TX Ethernet port and communication is
facilitated through the use of Simple Network Management Protocol (SNMP). The 3505FC handles all
SNMP communications between the frame (3505FR) and the network manager (NMS), and serves as
a gateway to individual SFP’s in the frame. A custom serial cable (Evertz part number: WP-DB9M-
2XDB9F-6FT) is included with each 3505FR frame and is required to configure main and redundant
3505FC. When not in use, store the serial cable in a safe place as it may be needed in the future.
5.1.
3505 FRAME CONTROLLER CONFIGURATION
This step by step guide will allow the user to change the Ethernet settings for SNMP communications.
1) Connect DB9M end of the cable to the port labeled SERIAL COM on the rear side of the
3505FR frame. Connect DB9F1 end of cable to HyperTerminal for configuration of FC1.
Connect DB9F2 end of the cable to HyperTerminal for configuration of FC2.
2) Use the following COM Port Settings to properly communicate with the 3505FC:
a. Baud: 115200
b. Data: 8 bit
c. Parity: none
d. Stop Bits: 2
e. Flow Control: none
3) Login to the configuration menu using user name “customer”
4) Modify network parameters by entering the (2) Network Settings menu. The following Network
Parameters are available for modification:
(1) IP Address
[
Displays current IP Address]
(2) Netmask
[
Displays current Netmask Address]
(3) Gateway
[
Displays current Gateway Address]
(4) Broadcast
[
Displays current Broadcast Address]
5) Modify SNMP Settings by entering the (3) SNMP Settings menu. The following SNMP
parameters are available for modification:
(1) Select SNMP v1/v3
[
Displays current SNMP version]
(2) SNMPv1 Settings
[Enter to modify SNMPv1 Settings]
(3) SNMPv3 Settings
[Enter to modify SNMPv3 Settings]
(4) Trap Setup
[Enter to modify Trap Destinations]