2430DAC-HD HDTV Digital to Analog Converter Manual
2430DAC-HD - 6
Revision
1.2
6.
UPGRADING THE 2430DAC-HD FIRMWARE
The 2430DAC-HD module is fitted with a COM port connector that can be connected to a PC with a
straight through cable.
6.1. REQUIREMENTS
You will need the following equipment in order to update the 2430DAC-HD Firmware
•
PC with available communications port. The communication speed is 57600 baud, therefore a 486 PC
or better with a 16550 UART based communications port is recommended.
•
“Straight-thru” serial extension cable (DB9 female to DB9 male) or (DB25 female to DB9 male)
•
Terminal program that is capable of Xmodem file transfer protocol (such as HyperTerminal)
•
New firmware supplied by Evertz.
6.2. UPDATE
PROCEDURE
6.2.1. Part 1 – Configuring the unit for Firmware upgrades
1. Connect the 9 pin male connector on the straight through serial extension cable to the COM port on
the end of the 2430DAC-HD. Connect the 9 pin female connector to the PCs’ RS-232 communications
port
6.2.2. Part 2 – Terminal program Setup
2. Start the terminal program.
3. Configure the port settings of the terminal program as follows:
Baud
57600
Parity
no
Data bits
8
Stop bits
2
Flow Control
None
4. Apply power to the 2430DAC-HD. After the unit powers up, a banner with the boot code version
information should appear in the terminal window. The cursor to the right of the word “BOOT>” should
be spinning for about 5 seconds then the unit will continue to boot.
For example:
EVERTZ 7700PB MONITOR 1.0
COPYRIGHT 1997, 1998, 1999 EVERTZ MICROSYSTEMS LTD.
COLD BOOT |
5. The following is a list of possible reasons for failed communications:
•
Defective 2430DAC-HD Serial Upgrade cable.
•
Wrong communications port selected in the terminal program.
•
Improper port settings in the terminal program. (Refer to step 7 for settings).