2. INSTALLATION
The 2408LT comes in a die cast enclosure with integral mounting flanges. It is recommended that the
enclosure be mounted on a flat surface with the connectors facing down. For units with the -WP option
exposed to the elements, while not required to prevent water ingress into the unit, good outdoor
installation practice suggests the use of waterproof connectors, boots and/or protecting connectors with a
wrap of Scotch 130C rubber tape followed by Scotch Super 88 vinyl tape, or equivalent.
Figure 2-1: 2408LT Module
Figure 2-2: 2408LT Mounting Hole Centers and Dimensions – mm [in]