2406DT13-F2
User Manual
Page - 8
Revision 1.0
Figure
3-3 : Wall/Panel Mounting
3.3. LED INDICATIONS
The
Three
LEDs indicate as follows:
POWER:
Power indicator.
Steady:
Power On.
OFF:
Power Off.
RECEIVE DATA:
RX Indicator.
Flashing:
Receiving data from Fiber links.
TRANSMIT DATA:
TX Indicator.
Flashing:
Transmitting data to Fiber links.
3.4. TROUBLE SHOOTING
Make sure the Power LED is ON and the RX and TX LEDs are OFF when there is no data
communication.
Check the connections as is shown in Figure
Perform a loopback test by using CommFront’s 232Analyzer software:
•
Connect “FiberTx” to “FiberRx” by using a fiber optic patch cord cable and connect the PC’s
RS-232 (or RS-485/422) to FBR-Serial-2 according to Figure
•
Send commands from the 232Analyzer software. You should receive an echo of the commands
sent. By performing a simple loopback test like this, you can test both the COM port and fiber
optic module. This is very helpful when you are in doubt about the performance of your
converter.