SMOKE DETECTOR
The photoelectric Smoke Detector is a Z-Wave
TM
enabled device which is fully
compatible with any Z-Wave
TM
enabled network. Z-Wave
TM
enabled devices
displaying the Z-Wave
TM
logo can also be used with it regardless of the
manufacturer, and ours can also be used in other manufacturer’s Z-Wave
TM
enabled networks. Inclusion of this detector on other manufacturer’s Wireless
Controller menu allows remote operation of connected modules when the
detector is triggered. Z-Wave node in the system also acts as a repeater, so as
to re-transmit the RF signal to ensure that the signal is received by its intended
destination by routing the signal around obstacles and radio dead spots.
The detector is designed to sense smoke that comes into the detector chamber.
It does not sense gas, heat, or flame. The working principle is when the smoke
detector detects a certain density of smoke, the horn of smoke detector will
sound and in the meantime, the detector will emit the signals to the associated
devices for further execution. It can provide precious time for you and your
family to escape before a fire spreads.
Product Overview
Battery Compartment Cover
LED
Link Key
Test/Silence Button
Tamper Switch
Mounting Bracket
Buzzer
Bracket Fastener
Adding to Z-Wave
TM
Network
Inside the detector, there is a link key which is used to carry out the function of
inclusion, exclusion, association and reset. When battery is applied for the first
time, the LED will flash on and off alternately and repeatedly for 4 minutes,
implying that it has not been assigned a node ID and cannot work with Z-Wave
enabled devices. The Smoke Detector will stay “awake” for 10 minutes when
power is first applied to allow time for configuration. This unit supports the Auto
Inclusion function when power is applied and no node ID is stored in the memory.
The Detector may automatically execute the function of inclusion when...
Auto Inclusion
1. The power is applied for the first time and no node ID has been stored in
the detector.
2. The execution of exclusion/reset is successful where the stored node ID is
cleared.
Note:
The duration for Auto Inclusion is 4 minutes during which period the node
information of explorer frame will be emitted once every 5 seconds. Unlike the
“inclusion” procedure shown in the table below, the execution of Auto Inclusion
is automatic without the necessity of pressing the link key.
Action/Status Description
LED & Buzzer Indication
No node ID
The Z-Wave Controller does not allocate a
node ID to the detector.
LED 2-second on, 2-second off
Inclusion
1.
Have the Z-Wave Controller enter
inclusion mode.
LED flashes and buzzer sounds
when link key is pressed. LED
lights for 1 second and buzzer
sounds for 1 second upon
successful operation.
2. Pressing link key three times within 1.5
seconds will enter inclusion mode.
3.
Detector stays “awake” for 10 minutes.
Exclusion
1. Have the Z-Wave Controller enter
exclusion mode.
LED flashes and buzzer sounds
when link key is pressed. LED
lights for 1 second and buzzer
sounds for 1 second upon
successful operation.
2. Pressing link key three times within 1.5
seconds will enter exclusion mode.
3.
Detector stays “awake” for 10 minutes.
Reset
1. Pressing link key three times within 1.5
seconds will enter exclusion mode.
LED flashes and buzzer sounds
when link key is pressed.
2. Within 1 second, press link key again
and hold until LED is off (about 5 sec.).
LED is on for 5 seconds and
buzzer sounds for 5 seconds.
3. Node ID is excluded, and the device
reverts to factory default state.
LED 2-second on, 2-second off