background image

AD126 

  LAMP MODULE 

 

This  plug-in  Lamp  Module  is  a  transceiver  which  is  a  Z-Wave

TM

  enabled  device 

and  is  fully  compatible  with  any  Z-Wave

TM

  enabled  network.  Z-Wave

TM

  enabled 

devices  displaying  the  Z-Wave

TM

  logo  can  also  be  used  with  it  regardless  of  the 

manufacturer,  and  ours  can  also  be  used  in  other  manufacturer’s  Z-Wave

TM

 

enabled  networks.    Inclusion  of  the  Lamp  module  on  other  manufacturer’s 
Wireless  Controller  menu  allows  remote  On/Off  control  and  dimming  of  lamps 
connected.    Each  module  is  designed  to  act  as  a  repeater.    Repeaters  will 
re-transmit  the  RF  signal  to  ensure  that  the  signal  is  received  by  its  intended 
destination by routing the signal around obstacles and radio dead spots.   
 

Adding to Z-Wave

TM

 Network 

 
In the front casing, there is an On/Off/Dim knob which is used to carry out inclusion, 
exclusion 

or 

association. 

Put 

Z-Wave

TM

 

Wireless 

Controller 

into 

inclusion/exclusion mode, and then press the knob on the Module to complete the 
inclusion/exclusion process.    Refer to the table below: 
 
 
 
 
 
 
 

 
 
 

Function 

Description 

Inclusion 

1.  Put the Z-Wave Controller into inclusion mode. 

2.  Press the On/Off/Dim knob once to enter inclusion mode. 

Exclusion 

1.  Put the Z-Wave Controller into exclusion mode. 

2.  Press the On/Off/Dim knob once to enter exclusion mode. 

3.  Node ID has been excluded. 

Association 

1.  Operate the Z-Wave Controller to start association process. 

2.    Press the On/Off/Dim knob once to execute association. 

 

Installation 
 

1.  Plug this Lamp module into a wall outlet near the lamp to be controlled. 
 
2.  Plug the lamp into the Lamp Module. There are two outlets at different sides of 

AD126. The lamp plugged into the controllable outlet can be controlled by the 
On/Off/Dim  knob  and  remote  controller,  its  maximum  load  is  300  watts.  The 
other  side  acts  as  a  pass-through  outlet  which  is  non-controlled  by  the 
On/Off/Dim knob and remote controller. 

 
3.  Make  sure  the  total  load  of  both  outlets  cannot  exceed  1500  watts  which 

means if the load of controllable outlet is changed; the other pass-through will 
be  altered  accordingly.  For  instance,  if  the  load  of  controllable  outlet  is  about 
300 watts,

 

the other should be 1200 watts. When the load of controllable outlet 

consumes as 0 watts, the other will be 1500 watts. 

 
4.  Turn the knob or switch on the lamp to the ON position. 
 
5.  To  manually  turn  ON  the  AD126  Lamp  Module,  press  and  release  the 

On/Off/Dim  knob.  The  red  indicator  LED  will  turn  ON,  and  the  lamp  plugged 
into the AD126 Lamp Module will also turn ON. 

 
6.  To manually turn OFF the AD126 Lamp Module, simply press and release the 

On/Off/Dim  knob.  The  red  indicator  LED  will  turn  OFF  and  the  lamp  plugged 
into the AD126 Lamp Module will also turn OFF. 

 
7.  To  manually  dim  the  AD126  Lamp  Module,  press  and  hold  the  On/Off/Dim 

knob until the desired lighting level has been reached. 

 

Note:  Dimming  an  inductive  load,  such  as  a  motor  or  a  transformer,  could 
impair the dimmer and load attached as well. 

 
 

Programming 

 

The On/Off/Dim knob allows the user 

Turn on, off or dim the lamp attached 

Include or exclude the module from the Z-Wave

TM

 system 

Control other Z-Wave

TM

 enabled devices 

 
 
 

On /Off / Dim knob 

Controllable outlet 

Pass-through outlet 

Отзывы: