background image

SELECTING A MOUNTING LOCATION

1.   Give consideration to the weight of the unit when operating (filled with water). Operating weights 

of the QC7I Systems are:

  •  Single System - 9 lbs. (4.0 kg.)
  •  Twin System - 19 lbs. (8.5 kg)
  •  Triple System - 27 lbs. (12 kg)
  •  Quad System - 36 lbs. (20 kg)
2.  The location should allow for:

 

•   Minimum clearance of 2-1/2” under the cartridge(s) so it can be lowered for removal and 

replacement.

 

•  Adequate space for “in” and “out” water line connections.

 

•   Be near a drain for flushing and near a 110V outlet if the accessory (sold separately) Everguard 

Low Pressure Alarm is used. See Figures 1-8.

3.   If used in conjunction with the SR-X feeder, the SR-X should be mounted after the QC7I Series 

Filter and as near the equipment as possible. If possible, keep at least 6” available to the left and 
the right of the QC7I System in the event poor quality water conditions require the installation of 
the optional Everpure E-Series Prefilter. 

WARNING: 

Do not use the MH cartridge in conjunction with the SR-X.

OPERATING SPECIFICATIONS*

Combined Model Name

Replacement 

Cartridge

Flow Rate

Capacity

QC7I Single - MC

MC

1.67 gpm (6.3 lpm)

9,000 gal (34,000 L)

QC7I Single - MC

2

MC

2

1.67 gpm (6.3 lpm)

9,000 gal (34,000 L)

QC7I Single - MH

MH

1.67 gpm (6.3 lpm)

9,000 gal (34,000 L)

QC7I Single - MH

2

MH

2

1.67 gpm (6.3 lpm)

9,000 gal (34,000 L)

QC7I Single - TO

TO

1.5 gpm (18.9 lpm)

30,000 gal (113,550 L)

QC7I Single - CV

CV

1.67 gpm (6.3 lpm)

7,500 gal (28,390 L)

QC7I Single - XCV

XCV

1.67 gpm (6.3 lpm)

10,000 gal (37,850 L)

QC7I Single - XC

XC

1.67 gpm (6.3 lpm)

12,000 gal (45,420 L)

QC7I Single - XC

2

XC

2

1.67 gpm (6.3 lpm)

12,000 gal (45,420 L)

QC7I Single - 7CB5

7CB5

2.5 gpm (9.4 lpm)

10,000 gal (37,850 L)

QC7I Single - 7CB5-K

7CB5-K

2.5 gpm (9.4 lpm)

10,000 gal (37,850 L)

QC7I Single - 7CB5-S

7CB5-S

2.5 gpm (9.4 lpm)

10,000 gal (37,850 L)

Combined Model Name

Replacement 

Cartridge

Flow Rate

Capacity

QC7I Twin - MC

MC

3.3 gpm (12.6 lpm)

18,000 gal (68,000 L)

QC7I Twin - MC

2

MC

2

3.3 gpm (12.6 lpm)

18,000 gal (68,000 L)

QC7I Twin - MH

MH

3.3 gpm (12.6 lpm)

18,000 gal (68,000 L)

QC7I Twin - MH

2

MH

2

3.3 gpm (12.6 lpm)

18,000 gal (68,000 L)

QC7I Twin - TO

TO

3.0 gpm (37.8 lpm)

60,000 gal (227,100 L)

QC7I Twin - CV

CV

3.3 gpm (12.6 lpm)

15,000 gal (56,780 L)

QC7I Twin - XCV

XCV

3.3 gpm (12.6 lpm)

20,000 gal (75,700 L)

QC7I Twin - XC

XC

3.3 gpm (12.6 lpm)

24,000 gal (90,840 L)

QC7I Twin - XC

2

XC

2

3.3 gpm (12.6 lpm)

24,000 gal (90,840 L)

QC7I Twin - 7CB5

7CB5

5.0 gpm (18.9 lpm)

20,000 gal (75,700 L)

QC7I Twin - 7CB5-K

7CB5-K

5.0 gpm (18.9 lpm)

20,000 gal (75,700 L)

QC7I Twin - 7CB5-S

7CB5-S

5.0 gpm (18.9 lpm)

20,000 gal (75,700 L)

Figure 1 – Single System

 

EV3024-87D   DE05

Installation and Operation Guide

QC7I Series Water Filters

Manufactured by Everpure

Figure 2 – Twin System

Figure 4 – Quad System

Figure 3 – Triple System