background image

 

 

 

 

 

 

                      FT2B.ME.062011.IM   

 (Ref) Item (Qty) 

  (A) M8 x 63 Lag Bolt (x4)             (B) Lag Bolt Washer (x4)             (C) Concrete Anchor (x4)              (D) M4 x 12 Bolt (x4)   

          (E) M4 x 20 Bolt (x4)                   (F) M6 x 12 Bolt (x4)                  (G) M6 x 30 Bolt (x4)                (H) M8 x 12 Bolt (x4)             

  (I) M8 x 30 Bolt (x4)         (J) M6 Washer (x4)         (K) Spacer (x8)         (L) Tilt Adjustment Knob (x2)         (M) M4 x 10 Screw (x2) 

EM-FT2B 

PLEASE READ THESE INSTRUCTIONS CAREFULLY AND KEEP FOR FUTURE 
REFERENCE! IF YOU DO NOT UNDERSTAND THE INSTRUCTIONS, OR DO NOT 
FEEL THAT YOU CAN FOLLOW THEM SAFELY, CONTACT A QUALIFIED  
CONTRACTOR. THE WARRANTY WILL BE HONOURED IF ACCOMPANIED BY AN 
ORIGINAL SALES RECEIPT, AND ONLY IF THE INSTRUCTIONS HAVE BEEN  
FOLLOWED EXACTLY.  

 

•  The EM-FT2B is designed to mount a flat panel onto a vertical wall. Hardware for mounting to a 

wood stud is included. For mounting to any other surface, contact a qualified contractor. 

•  The wall or mounting surface must be capable of supporting the combined weight of the mount 

and the flat panel, otherwise the structure must be reinforced. 

•  Safety gear and proper tools must be used. Failure to use safety gear can result in property 

damage, serious injury, or death. 

•  Follow all instructions and recommendations regarding adequate ventilation and suitable         

locations for mounting your flat panel. Consult the owner‘s manual for your flat panel for more            
information. 

•  This product will hold flat panels up to 46 inches and weighing up to 100 lbs. 
•  VESA 400mm x 400mm 
•  Two people are recommended for installation 

Tools Required 

• 

Phillips head screw driver 

• 

Rachet or driver with 13mm (1/2”) socket 

• 

Electric or portable drill 

• 

6mm (1/4”) drill bit and stud finder for drywall installation 

• 

10mm (3/8”) masonry bits for concrete installation 

Instructions 

Содержание EM-FT2B

Страница 1: ... included For mounting to any other surface contact a qualified contractor The wall or mounting surface must be capable of supporting the combined weight of the mount and the flat panel otherwise the structure must be reinforced Safety gear and proper tools must be used Failure to use safety gear can result in property damage serious injury or death Follow all instructions and recommendations rega...

Страница 2: ... level after both screws are secured Fig 1 Part 1B Mounting the wall plate to concrete 1 Place the wall plate against the wall in the desired location and level it using the integrated bubble level 2 While another person holds in the wall plate mark four evenly spaced locations on the wall for securing the mount see Fig 3 3 Set the wall plate aside and drill a 10 mm 3 8 hole at each marked locatio...

Страница 3: ... passes through both mount arms see Fig 5 Attach the tilt adjust ment knobs L using the M4x10 screws M Make the tilt adjustment knobs point downwards NOTE If the holes of the mount do not line up with the holes on your flat panel check to make sure that your flat panel is VESA compatible This mount can only be used with flat panels that are VESA 200 x 200 compatible Fig 5 4 Remove the clips locate...

Страница 4: ...knocked from the mount Part 4 Operation and Adjustment 1 To change the tilt angle of your flat panel hold the flat panel firmly with one hand and rotate one of the tilt adjustment knobs towards the flat panel away from the wall to unlock the tilt Make sure you rotate the knob fully Carefully move the flat panel to the desired position and then return the tilt adjustment knob to its original positi...

Страница 5: ...communiquer avec un technicien qualifié Le mur ou la surface de montage doit être capable de supporter le poids combiné du support et de l écran sinon la structure doit être renforcée Un équipement de sécurité et des outils appropriés doivent être utilisés Ne pas utiliser d équipe ment de sécurité peut entraîner des dommages matériels des blessures graves ou la mort Suivez toutes les instructions ...

Страница 6: ...s au niveau après avoir fixé les vis Fig 1 Partie 1B Montage de la plaque murale sur du béton 1 Placez la plaque murale contre le mur à l endroit désiré et alignez la à l aide du niveau à bulle fourni 2 Avec l aide d une autre personne qui tient la plaque murale marquez quatre emplacements à même distance l un de l autre sur le mur voir Fig 3 là où vous désirez installer le support 3 Mettez la pla...

Страница 7: ...ar les deux bras de montage voir Fig 5 Fixez les boutons de réglage de l inclinaison L en utilisant les vis M4 x 10 M Pointez les boutons de réglage de l inclinaison vers le bas REMARQUE Si les trous de montage ne sont pas alignés avec les trous au dos de l écran assurez vous que votre écran soit compatible VESA Ce support ne peut être utilisé qu avec des écrans plats compatibles VESA 200 x 200 Fi...

Страница 8: ... Partie 4 Utilisation et entretien 1 Pour changer l angle d inclinaison de votre écran tenez fermement l écran d une main et tournez l un des boutons de réglage de l inclinaison vers l écran en l éloignant du mur pour déverrouiller l inclinaison Assurez vous de tourner le bouton complètement Placez l écran à la position désirée avec précaution puis retournez le bouton de réglage d inclinaison à sa...

Отзывы: