background image

ES1625-31   

16-port 10/100M PoE + 2 Gigabit Copper/SFP Combo Rackmount 
Web Smart PoE Switch

   

 

                                                                                 

 

 

User’s Manual 

 
 
 
 
 
 
 
 

  

 

 
 
 
 
 
 
 
 
 
 

Copyright © EverFocus Electronics Corp, 

Release Date: September, 2013 

 

Notice: This content is subject to be changed without notice. 

Содержание ES1625-31

Страница 1: ... port 10 100M PoE 2 Gigabit Copper SFP Combo Rackmount Web Smart PoE Switch User s Manual Copyright EverFocus Electronics Corp Release Date September 2013 Notice This content is subject to be changed without notice ...

Страница 2: ...erfocus Electronics Corporation Release Date September 2013 QuickTime is a registered trademark of the Apple Computer Inc Windows is a registered trademark of the Microsoft Corporation Linksys is a registered trademark of the Linksys Corporation D Link is a registered trademark of the D Link Corporation DynDNS is a registered trademark of the DynDNS org Corporation Other product and company names ...

Страница 3: ...nce will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect ...

Страница 4: ...tors 4 2 4 Rear Panel 5 2 5 Hardware Installation 5 3 User Log In 6 4 Administrator 8 4 1 Authentication Configuration 8 4 2 System IP Configuration 8 4 3 System Status 9 4 4 Load Default Setting 10 4 5 Firmware Update 10 4 6 Reboot Device 11 5 Port Management 12 5 1 Port Configuration 12 5 2 Port Mirroring 13 5 3 Bandwidth Control 13 5 4 Broadcast Storm Control 14 5 5 PoE 15 6 VLAN Setting 16 6 1...

Страница 5: ... 1p IP DS based 22 8 Security 23 8 1 MAC Address Binding 23 8 2 TCP UDP Filter 23 9 Spanning Tree 24 9 1 STP Bridge Settings 24 9 2 STP Port Settings 25 9 3 Loopback Detection Settings 26 10 Trunking 27 11 Backup Recovery 28 12 Miscellaneous 29 13 Logout 30 14 Specification 31 ...

Страница 6: ...VLAN function to provide better traffic management reduces latency improve security and save bandwidth This is also a cost saving feature as it reduces the need to add additional hardware to the network These 16 10 100Mbps RJ 45 support the IEEE 802 3at PoE protocol Each port and transmit a maximum power 30 watts User can also enable or disable power supply on PoE ports from UI 1 2 Key Features 1 ...

Страница 7: ...E 802 at PoE IEEE 802 3ad Link Aggregation IEEE 802 1d Spanning tree protocol IEEE 802 1w Rapid Spanning tree protocol IEEE 802 1x Port based Network Access Control IEEE 802 1Q VLAN IEEE 802 1p Class of Service Number of Port 16 port 10 100BaseTX with PoE 2 port Combo Gigabit uplink RJ 45 SFP 1 2 3 Mechanical LED Indicator Per Port Link Act PoE Port Act Status Per Unit Power Power Consumption 250W...

Страница 8: ...ess 4K Buffer Memory 2 75Mb Transmission Method Store and Forward 1 3 Package Before you start to install this switch please verify your package that contains the following items 1 One Fast Ethernet PoE Switch 2 One EU Power Cord 3 A User Manual CD 4 Rack mount kit ...

Страница 9: ... The front panel of the web smart switch consists of 16 10 100Base TX RJ 45 ports and 2 combo gigabit uplink RJ 45 SFP ports The LED Indicators are also located on the front panel 2 3 LED Indicators The LED Indicators present real time information of systematic operation status The following table provides description of LED status and their meaning LED Status Description No Of LED Power On Power ...

Страница 10: ...g is placed at the rear panel of the switch right side shown as below 2 5 Hardware Installation Set the switch on a large flat space with a power socket close by The flat space should be clean smooth level and sturdy Make sure there is enough clearance around the switch to allow attachment of cables power cord and allow air circulation The last use twisted pair cable to connect this switch to your...

Страница 11: ...edure At the first open the web browser and go to 192 168 2 1 site then the user will see the login screen Key in the password to pass the authentication then clicks the OK The log in process is completed and comes out the sign Password successfully entered Log in ID admin Password admin Note It will show error message if you key in wrong user name or password Chapter 3 ...

Страница 12: ...ES1625 31 7 Main Page ...

Страница 13: ...guration This page shows authentication configuration information User can set new Username and Password in this page 4 2 System IP Configuration This page shows system configuration including the current IP address and sub net mask and gateway Chapter 4 ...

Страница 14: ...r login screen automatically 4 3 System Status This page displays the information about the switch of MAC address how many ports it has system version and Besides users can also fill in up to 15 characters in the Comment Contact and Location field for note MAC Address Displays the unique hardware address assigned by manufacturer default Number of Ports Displays number of ports in the switch System...

Страница 15: ... following procedures Press the Load default button for 3 seconds until you see the LED blinking 2 When LED starts blinking it means the CPU is executing the load default procedure You can release the button now After completing this procedure all the factory default value will be restored It includes the IP address the user name the password and all switch configurations 4 5 Firmware Update Befor...

Страница 16: ...the old web code will be erased Then you can select the image file and press update button to update the firmware you need 4 6 Reboot Device Click Confirm button to reboot the device Note The reboot is for software base instead of hardware base ...

Страница 17: ...sable users have to set the connection speed to the ports ticked Duplex When the Auto Negotiation column is set as Disable users have to set the connection mode in Half Full to the ports ticked Pause Flow Control for connection at speed of 10 100Mbps in Full duplex mode Backpressure Flow Control for connection at speed of 10 100Mbps in Half duplex mode TX RX Capability When the Auto Negotiation co...

Страница 18: ... port Users can connect the mirroring port to LAN analyzer or Netxray Monitored Packets Pull down the selection menu to choose what kind of packet is to be monitored Source Port The ports that the user wants to monitor All monitored port traffic will be copied to mirroring destination port Users can select multiple source ports by ticking the check boxes beneath the port number label to be monitor...

Страница 19: ...adcast packets is counted in every time unit One time unit is 500 us for 10Mbps speed and 5ms for 100Mbps The excessive broadcast packet will be discarded For those broadcast packets incoming from the un selected port the switch treats it as the normal traffic Threshold Type in the threshold in the range between 1 and 63 to limit the maximum byte counts which a port can send or receive in a period...

Страница 20: ...ES1625 31 15 5 5 PoE User could know per PoE port out power status in this page and also enable or disable per port ...

Страница 21: ...sed VLAN is for separating traffic only on this single switch There is no handover of network traffic within VLAN groups to other switches For the handover to other switches use Tag Based VLAN In VLAN Mode you can switch from Tag to Port Based VLAN Port Based VLAN is the default mode After having switched to Tag Based VLAN Mode the screen changes On this screen you can now define and configure you...

Страница 22: ...for Tag Based and Port Based VLAN Mode The screen here looks different whether you run Tag Based or Port Based Mode VLAN Member in Port Based Mode In Port Based Mode you see a matrix of your 8 Ports Simply select the port on top screen you want to configure click on Read and then select or deselect the ports that are on the same VLAN group In this configuration mode you do not need to worry about ...

Страница 23: ...0 in the field right of VID Setting then select or deselect which ports are member of that group Your up and downlink ports need to member of every existing group Then click on add The new group with its setting will be displayed at the bottom of the screen With the PVID Setting you define to which VLAN group incoming traffic belongs Consider the example that Port 1 is member of group 100 and 101 ...

Страница 24: ...ng on VLAN Member Setting When VLAN member Setting is updated multi to 1 setting will be void and vice versa The disable port means the port which will be excluded in this setting All ports excluded in this setting are treated as the same VLAN group In a normal Tag Based VLAN network you will not need this configuration option ...

Страница 25: ...ceived packet count excluding the incorrect packet and the transmitted packet count Collision Count Transmit packet This category shows the packets outgoing from the switch and the count of collision Drop packet Receive packet This category shows the number of received valid packet and the number of dropped packet CRC packet Receive packet This category shows the received correct packet and receiv...

Страница 26: ...ckets to identify such classes but they do not guarantee delivery as do quality of service QoS functions which are implemented in the network devices 7 3 Priority Mode There are three priority modes available to specify the priority of packets being serviced Those include First In First Out All High Before Low and Weight Round Robin First In First Out Packets are placed into the queue and serviced...

Страница 27: ...ES1625 31 22 7 4 Port 802 1p IP DS based TCP UDP Port Based ...

Страница 28: ...the port Read Pull down the selection bar to choose a port number and click the read button to show the MAC addresses bound with the port or modify the MAC addresses Select Port Pull down the selection menu bar to choose a port number to be set Binding Enable or disable the binding function Click Update to have the configuration take effect 8 2TCP UDP Filter Chapter 8 ...

Страница 29: ...4096 Therefore there are 16 distinct values Hello Time Interval in seconds at which the root device transmits a configuration message BPDU frame Number between 1 10 default is 2 Max Age The maximum time in seconds a device can wait without receiving a configuration message before attempting to reconfigure That also means the maximum life time for a BPDU frame Number between 6 40 default is 20 Forw...

Страница 30: ...th between devices Therefore lower values should be assigned to ports attached to faster media and higher values assigned to ports with slower media Set the RSTP path cost on the port Number between 0 200000000 0 means auto generated path cost State Show the current port state includes designated port root port or blocked port Status Show the current port status includes forwarding disable etc ...

Страница 31: ...ES1625 31 26 9 3 Loopback Detection Settings ...

Страница 32: ... within the trunk group causes the network traffic to be directed to the remaining ports Load balancing is maintained whenever a link in a trunk is lost or returned to service This switch may use Port ID Source MAC Address Destination MAC Address or a combination of Source MAC Address and Destination MAC Address to be the selection for Trunk Hash Algorithm Traffic pattern on the network should be ...

Страница 33: ...witch configuration The user can save configuration file to a specified file If the user wants to recover the original configuration which is saved at the specified path just enter the password and then press the upload button Finally the original configuration of the switch will be recovered Chapter 11 ...

Страница 34: ...a useless packet To prevent these packets from wasting the bandwidth this switch provide an option for the administrator to enable the queue aging function VLAN Striding By selecting this function the switch will forward uni cast packets to the destination port no matter whether destination port is in the same VLAN IGMP Snooping When this function is enabled the switch will execute IGMP snooping v...

Страница 35: ...ault setting Please take the following steps to reset the Web Smart Switch back to the original default Step 1 Turn on the Web Smart Switch Step 2 Press and hold the reset button continuously for 5 seconds and release the reset button Step 3 The switch will reboot for 20 seconds and the configuration of switch will back to the default setting Key in the user ID and the password to pass the authent...

Страница 36: ... Features Number of Ports 18 10 100BaseTX with RJ 45 Connectors 16 port with PoE Gigabit Uplink 2x 10 100 1000BaseT RJ 45 Gigabit SFP Combo Port MAC Address 4K Buffer Memory 2 75Mb Transmission Method Store and Forward Smart Features Port Based VLAN 18 Tagged Based VLAN 32 VID 1 4094 STP RSTP IGMP Snooping V1 V2 Link Aggregation 1 Gigabit Ports Quality of Service QoS High Low queues 802 1p Securit...

Страница 37: ...pps Transmission Media 10 100BaseTX Cat 5 UTP STP 1000BaseT Cat 5 Cat 5E UTP STP LED Indicators Per Port Link Act PoE Act Status Per Unit Power Power Input 100 240 V AC 50 60Hz Power Output 53V DC Per Port Output Power Consumption 250 Watts Dimensions 44 440 332 mm H x W x D Operating Temperature 0 to 40 Storage Temperature 20 to 90 Humidity 10 to 90 RH non condensing Certifications FCC Class A CE...

Страница 38: ...3 5625 8189 www everfocus co jp info everfocus co jp EverFocus Europe UK Unit 12 Spitfire Business Park Hawker Road Croydon Surrey CR0 4WD UK TEL 44 20 8649 9757 44 845 430 9999 FAX 44 20 8649 9907 www everfocusuk co uk salesuk everfocus com EverFocus India Suite 803 Housefin Bhavan C 21 Bandra Kurla Complex Bandra East Mumbai 400051 India TEL 91 22 6128 8700 FAX 91 22 6128 8705 www everfocus in s...