54
4.4.6
Alarm-GPS Event Action
Press
to enter GPS Event Action Menu.
Figure 4-22 Alarm – GPS Event Action
Alarm Output: This will transmit a signal through the alarm output
relay. It can be set to either “NONE” (not
active), “1” (active) or “2” (active).
Output Type: Output action when alarm is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses “Enter” key.
Transparent: Alarm output remains active until event ends.
Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.
Timeout Duration: The amount of time the buzzer sounds when GPS event occurs. Duration selectable
from 1 to 150
seconds.
Pre-alarm Record: Check box to start copying recorded video to the hard disk from 5 seconds before the
video loss. (Pre-alarm recording rate will follow the “Normal” frame rate setting)
Email Notify: Check box to enable email notification when GPS event occurs. Email operation requires
that valid email settings have been entered in the Network Setting/Email setup screen.
Network Alarm: Check box to send out a network alarm to client PC. (requires PowerCon software and
setting up Alarm Server in Network Setup menu)
Click
button to return to the previous level of menu.
Содержание EMV400
Страница 1: ...User Manual E EM MV V4 40 00 0 D DV VR R ...
Страница 19: ...11 CAM POWER1 12V OUT 12V OUT GND GND GPS GND GPS_TX GPS_RX 12V CAM POWER2 12V OUT 12V OUT GND GND ...
Страница 42: ...34 Figure 4 2 Configuration Menu ...
Страница 96: ...88 ...
Страница 97: ...89 ...
Страница 106: ...98 Once the file finishes installing you will return to the screen like the one below ...