MENU
Alarm in
There is one alarm input. Please connect the alarm input in the same sequence as the
camera input BNC.
When alarm signal comes in, the Digital Video Recorder will do the following:
1. Display Alarm Message
2. Turn on the buzzer if the buzzer setting is on.
The
ALARM in
can be selected as normally open input or normally closed input:
Normally Open
: I
f the alarm input is selected as Normally Open input, then the
(N.O.)
input is opened normally, and shorted to the ground means an alarm happens.
Normally Close
: I
f the alarm input is selected as Normally Close input, then the
(N.C.)
input is shored to the ground normally, and opened input means an alarm
happens.
(c) Alarm in and alarm reset
There is 1 alarm sensor in for 1 channel and 1 alarm reset in, t he
alarm input can be set to Normally Open or Normally Closed by user
.
SENSOR 1
8
2 1
9
ALARM RESET
ALARM
CIRCUIT
15
24