background image

 

1    

 

 

 

 

WWW.EVERETIMAGING.COM 

CONTENT 

 

SAFETY GUIDES 

1

 

PACKING LIST

 

2

 

Qucik Start Guide

 

3

 

Dial Switch Settings (at the bottom of the camera) 

4

 

PRODUCT HIGHLIGHTS

 

6

 

TECHNICAL SPECIFICATIONS

 

7

 

CAMERA INTERFACE

 

9

 

CAMERA DIMENSIONS

 

10

 

IR REMOTE CONTROLLER

 

11

 

OSD MENU

 

14

 

Webinterface

 

24

 

VISCA OVER IP

 

41

 

HOW TO USE VISCA OVER IP

 

41

 

 

 

SAFETY GUIDES 

1.

       

Before operation, please fully read and follow all instructions in the manual. 

2.

       

The camera power input range is 100-240 VAC (50-60Hz), ensure the power supply input 
within this rate before powering on. 

3.

       

The camera power voltage is DC12V/8W. We suggest you use it with the original power 
supply adapter or use PoE+ (IEEE802.3at) compatible switch. 

4.

       

Please keep the power cable, video cable and control cable in a safe place. Protect all 
cables especially the connectors. 

5.

       

Operational environment: 0

-50

, humidity less than 90%.To avoid any danger, do not 

put anything inside the camera, and keep away from the corrosive liquid. 

6.

       

Avoid stress, vibration and damp during transportation, storage and installation. 

7.

       

Do not detatch the camera housing and cover. For any service, please contact authorized 
Everet technicians. 

8.

       

Video cable and control cable should be individually shielded, and cannot be substituted 
with other cables. 

9.

  

Do not direct the camera lens towards strong light, such as the sun or the intensive light. 

Содержание EVP412N

Страница 1: ...EVERET EVP412N 12x NDI FHD PTZ Video Camera User Manual Version V1 0 English...

Страница 2: ...V 8W We suggest you use it with the original power supply adapter or use PoE IEEE802 3at compatible switch 4 Please keep the power cable video cable and control cable in a safe place Protect all cable...

Страница 3: ...a head by hand NEVER MOVE THE CAMERA MANUALLY WHEN IT IS WORKING 12 Put the camera on fixed and smooth desk or platform avoid leaned installation 13 Power Supply Polarity Drawing Note The video qualit...

Страница 4: ...display does not support this resolution you can easily change the resolution with the IR remote control Please go to chapter IR Remote Controller in this manual and follow instructions Change video o...

Страница 5: ...4 WWW EVERETIMAGING COM Dial Switch Settings at the bottom of the camera Dial Switch ARM SW 1 SW 2 Instruction 1 OFF OFF Updating mode 2 ON OFF Debugging mode 3 OFF ON Undefined 4 ON ON Working mode...

Страница 6: ...Dial Switch SW 3 SW 4 Instruction 1 OFF OFF reserve 2 ON OFF reserve 3 OFF ON reserve 4 ON ON reserve Dial Switch USB SW 5 SW 6 Instruction 1 OFF OFF Undefined 2 ON OFF Working mode 3 OFF ON Updating...

Страница 7: ...mance when zooming or moving Smooth PTZ mechanical design accurate pan tilt motor control 128 presets supported Standard Sony VISCA VISCA over IP PELCO P PELCO D control protocol IP VISCA over both TC...

Страница 8: ...30 IP Main Stream 1920 1080 3 30 1280 720 3 30 1024 576 3 30 Sub Stream 1280 720 3 30 1024 576 3 30 640 360 3 30 USB 3 0 1920 1080P60 50 30 25 1280 720P60 50 30 1280 720P25 1024 576P30 960 540P30 640...

Страница 9: ...isca Pelco P Pelco D POE Supported Daisy Chain Support RS232 serial daisy chain Minimum Lux 0 1 lux White Balance Auto Indoor Outdoor Manual One Push ATW Exposure Auto Manual Shutter Priority Iris Pri...

Страница 10: ...AMERA INTERFACE 1 Camera Lens 2 Camera Base 3 IR Receiver Panel 4 Power Indicator Light 5 Dial Switch 6 Tripod Screw Hole 7 Installation Hole 8 RS232 control port input 9 RS232 control port output 10...

Страница 11: ...10 WWW EVERETIMAGING COM CAMERA DIMENSIONS...

Страница 12: ...overrules this Default PTZ position when the camera is rebooted is the 0 Preset You can always go back to the Default PTZ position by pressing the OK button NOTE The above is only applicable when sole...

Страница 13: ...preset long press 3 seconds the number key to set preset Call preset Short press the number key to run preset CLR PRE CLEAR PRESET Press CLR PRE and then choose number key of the preset you like to cl...

Страница 14: ...Change Video output resolution for SDI HDMI and USB 3 Long press one of the blue resolution buttons until the screen turns black When the screen turns black let go of the button and the video output w...

Страница 15: ...h the menu Once selected the main menu will change to blue background and the right side will show all sub menu options 3 Press the navigate RIGHT key to enter sub menu use UP DOWN key to select the s...

Страница 16: ...CO P D 1 255 Default 1 BAUD RATE 2400 4800 9600 115200 Default 9600 PTL LOCK Protocol lock once set above protocol setting will be locked Default OFF RS485 RS485 ON OFF Default OFF VISCA To select VIS...

Страница 17: ...etting CLOSE F1 5 only valid under manual mode Default AUTO GAIN Gain setting 0dB 28dB only valid under manual mode Default AUTO BRIGHT Bright setting 0 15 Default 8 EBRIGHT Bright setting 0 15 only v...

Страница 18: ...r colored lighting this is saved as the camera s white reference and camera now auto white balances using the new reference white instead of its internal reference ATW Auto Tracking White Balance ATW...

Страница 19: ...UTO 0 4 the bigger value the less motion noise on image high value will cause image smear Default AUTO SHARPNESS Sharpness setting 0 15 the higher value edge of the image will be sharpened Default AUT...

Страница 20: ...LIP VER Flip vertical Default OFF PT SPD Pan Tilt speed Default 18 ZOOM SPD Zoom speed Default 5 MENU MIR Turn on off left menu mirror function Default NORMAL PRE FRZ Preset Freeze function Freeze las...

Страница 21: ...ORMAT 1080P60 1080I50 Once selected press OK key to confirm if it is the selected video format there is no change 1080P50 1080I59 94 1080P30 720P60 1080P25 720P50 1080P59 94 720P30 1080P29 97 720P25 1...

Страница 22: ...tton to select item to set and using number button to set parameter Press menu button to return IP 192 168 001 188 MASK 255 255 255 000 GW Gateway 192 168 001 001 MAIN Stream 1920 1080 1280 720 1024 5...

Страница 23: ...RETIMAGING COM 11 Reset RESET SYS RESET Reset communication parameter to default CAM RESET Reset camera parameter to default PT RESET Reset pan tilt parameter to default ALL RESET Reset all parameter...

Страница 24: ...12 Info INFO IR ADDR Camera IR control address USB USB firmware version CLIENT Default client end protocol VISCA ARM VER ARM firmware version FPGA VER FPGA firmware version CAM VER Camera version RELE...

Страница 25: ...f the camera In this case you would need to change the Ethernet adapter settings of your PC to get in the same IP range ass the camera Please check on the internet how to do this according to the OS s...

Страница 26: ...u have successfully logged in you will see the live video image of your camera as below You will also be able to control following settings as you can see on the left image 1 PTZ 2 Zoom 3 Focus 4 Focu...

Страница 27: ...chose the encoding resolution 6 Set bitrate 7 Set Framerate 8 Bitrate control Variable or Constant Bitrate 9 Set I Frame interval NOTE We suggest keeping the resolution and framerate the same as your...

Страница 28: ...be enabled for the NDI to work Discovery server By enabling this feature the camera can be discovered discover by the NewTek NDI Discovery server receiving applications that are looking for video When...

Страница 29: ...28 WWW EVERETIMAGING COM 5 Image Adjust Focus Set camera to auto or manual focus Enable or disable Digital Zoom...

Страница 30: ...29 WWW EVERETIMAGING COM Exposure mode Auto Manual Iris Priority Shutter Priority and Brightness Priority White balance mode Auto Indoor Outdoor One Push Auto Tracking ATW Manual...

Страница 31: ...30 WWW EVERETIMAGING COM Image enable mirror flip backlight compensation WDR wide dynamic range and set Gamma Image quality configure brightness sharpness contrast and saturation...

Страница 32: ...31 WWW EVERETIMAGING COM Noise reduction includes 2D 3D reduction There is an on off option for 2D and off auto 1 4 options for 3D...

Страница 33: ...gateway and DNS HTTP Port 80 This is a standardized Port number to communicate between webclients and webservers We suggest not to change this unless you have specific reasons RTSP Port 554 This is th...

Страница 34: ...ile and then the ISP file Click upgrade to start the upgrade process Only use upgrade files from everet eu support website Note DO NOT power off or take other actions during the upgrade process the ca...

Страница 35: ...34 WWW EVERETIMAGING COM 8 Reset Options...

Страница 36: ...ccount Setting This is used for setting your login username and password First Input the accountname then input password twice click ok to finish settings Please remember account and password otherwis...

Страница 37: ...g NDI with H 265 Please follow instructions below if you are using vMix If you are using windows you need to download the HEVC APP from the MS store at first 1 Install the NDI Tools with the NDI versi...

Страница 38: ...Monitor to act as a router and server for delivery to multiple outboard displays NDI Screen Capture Capture and present the full screen display any combination of windows applications players and webc...

Страница 39: ...e from any NDI enabled receiving device anywhere on the network NDI Import I O for Adobe CC Import your media files captured and recorded from NDI sources into Adobe Creative Cloud software applicatio...

Страница 40: ...ments Suitable for WiFi remote and large scale networks NDI Screen Capture HX NDI Screen Capture HX is designed to work with a PC s GPU to capture your screen and make it available as an NDI source on...

Страница 41: ...Default RTMP main streaming address rtmp 192 168 1 188 1935 app rtmpstream0 Default RTMP sub streaming address rtmp 192 168 1 188 1935 app rtmpstream1 1 Run VLC Media Player 2 Select Media network st...

Страница 42: ...amera In the menu set VISCA option to OVER IP HOW TO USE VISCA OVER IP VISCA Command It means commands from controller to peripheral equipment when peripheral equipment receives commands then return A...

Страница 43: ...x11 Stores the reply for the VISCA command and VISCA inquiry or VISCA device setting command VISCA device setting command 0x01 0x20 Stores the VISCA device setting command Control command 0x02 0x00 St...

Страница 44: ...setting command Save VISCA equipment setting command packet Control command The following data is saved in control command payload Controlled reply The following data is saved in return command paylo...

Страница 45: ...mmand sequence number is same as last command the following chart will list the received message and status after resending the commands Sequence chart as specified Sequence chart when command lost Se...

Отзывы: