10 s. If no voltage increase is observed, the charger will
indicate an error – the battery symbol will flash and ERROR
message will appear.
Depending on the battery voltage it will automatically detect
Ni-MH and Li-ion batteries. When Li-ion cell is detected it is
possible to manually activate the Li-FePO4 charging mode as
described in point 6. Battery type symbol is indicated on LCD
display (Ni-MH, Li-ion, LiFePO4).
When inserting next batteries into the charger, the LCD will
always show the status of the last inserted cell. The user can
manually review other battery compartments by pressing
SLOT button.
If no further action is taken by the user, the charger will
start the charge process with default settings – with 500 mA
current.
8. Selecting operating modes and adjusting
charging current.
The default operating mode of UC-4000 is charging
(CHARGE) with a current of 500mA. Charging current can be
altered for Li-ion and Li-FePO batteries by pressing MODE
button for at least 2s. Active setting is indicated on LCD:
500mA or 1000 mA.
When charging Ni-MH cells the charging current is always set
at 500 mA.
Short press of MODE button will switch between
CHARGE
↔
DISCHARGE modes.
9