Set-Pro Control Operating Manual 

Ceramic version 

– July 2014 

 

Page 

1

 of 

19

 

                                          Use your Smart-phone to scan this QR code to watch Set-Pro how-to Programming Videos!

 

 
 

For Use with Set-Pro controlled Ceramic Kilns with a serial number greater than 107718.

 

 

SET-PRO 

w/ Express Mode 

 
 
 

 

 
 
 
 

CERAMIC FIRING

 

Control Operating Manual 

 
 
 
 
 
 
 

 

Содержание Set-Pro

Страница 1: ...2014 Page 1 of 19 Use your Smart phone to scan this QR code to watch Set Pro how to Programming Videos For Use with Set Pro controlled Ceramic Kilns with a serial number greater than 107718 SET PRO w...

Страница 2: ...d Metal Clay Express Mode please refer to the manuals disc included with your kiln visit our web site at www evenheat kiln com or contact us at info evenheat kiln com CAUTION The Set Pro is used to co...

Страница 3: ...details 7 Use the Up or Down arrow keys to select your desired pre heat time If no pre heat is desired select 00 00 8 Press the Enter key The display will read COnE You may choose any cone number bet...

Страница 4: ...choose You re choosing which of the 4User program numbers will be used to store your program Your choices are 1 thru 4 8 Press the Enter key SEG is displayed along with some number 9 Use the Up or Do...

Страница 5: ...formation during the programming process UP Arrow VIEW SEG SKIP SEG Used to select values when programming and allows for Viewing the current running segment as well as performing the Skip Ahead featu...

Страница 6: ...kiln temperature to 200 F 93 C and hold this temperature for a period of time chosen by you You may choose a pre heat hold time up to 100 hours It is not necessary to use the pre heat feature if you...

Страница 7: ...the left of the decimal point are in hours and values to the right of the decimal point are in minutes If you choose to not add any hold time at final temperature simply select 00 00 as your hold tim...

Страница 8: ...ds to know which of the 4 available locations you would like to store your Custom Mode program In other words a program number Your choices are 1 thru 4 7 Use the Up arrow key only to select the desir...

Страница 9: ...segment for your firing the display will read rA 2 along with some number If you have chosen to use only 1 segment for this firing skip ahead to line 21 for further instruction The Set Pro is asking f...

Страница 10: ...ring a hold period it s sometimes necessary to add just a little extra temperature to the programmed set point temperature The Set Pro allows you to add more temperature in 5 increments To Use the Add...

Страница 11: ...e Set Pro will finish its initialization process and then display IdLE Idle Idle simply means the Set Pro is at rest and is not running any programs 4 Press the Enter key one time to begin the Alarm s...

Страница 12: ...rt on page 18 of this manual Have a look at it and note that some cone numbers have a 0 in front of them and some do not Here s a cautionary example to alert you to the importance of using the proper...

Страница 13: ...nutes When programming a time value a red dot will illuminate in the middle of the four display digits Numbers to the left of the dot indicate hours and numbers to the right of the dot indicate minute...

Страница 14: ...e scale you are using please consult Evenheat if you wish to adjust this setting Maximum Programmable Temperature The maximum temperature and cone that can be programmed in the Set Pro is 2350 F 1288...

Страница 15: ...or 1 page 16 rA Rate page 8 bEGn Beginning Process Alarm page 11 F Fahrenheit page 14 rEdI Ready pages 7 9 botH Both Beginning and End Alarms page 11 FASt Fast page 7 rSLO Extra Slow N A bron Promethe...

Страница 16: ...mance standards the Set Pro automatically stops the firing and displays a corresponding Error Code describing the fault These codes are identified and described below tC FAIL tC alternating with FAIL...

Страница 17: ...ime User Defined Pre Heat if any 0 Min 0 Min User Defined Hold if any MEDIUM SPEED Segment 1 Segment 2 Segment 3 Segment 4 Rate 120 F Hr 400 F Hr 300 F Hr 120 F Hr Set Point Temperature 200 F 1050 F C...

Страница 18: ...F 04 1945 F 5 2167 F 019 1252 F 011 1607 F 03 1987 F 6 2232 F 018 1319 F 010 1657 F 02 2016 F 7 2262 F 017 1360 F 09 1688 F 01 2046 F 8 2280 F 016 1422 F 08 1728 F 1 2079 F 9 2300 F 015 1456 F 07 1789...

Страница 19: ...faulty The thermocouple circuit is broken at some point usually the thermocouple itself The thermocouple circuit consists of the thermocouple any connecting blocks and the thermocouple lead wire conn...