background image

EVCO S.p.A. | EVIF25TWX | Instruction sheet ver. 4.0 | Code 104IF25TWXA403 | Page 1 of 2 | PT 46/21 

EVIF25TWX/EVIF25SWX 

EVlinking Wi-Fi module 

 

 

 

 

EN 

ENGLISH 

powered by the controller or 12 VAC/15 VDC power supply 

clock 

TTL MODBUS port or RS-485 MODBUS port (according to the model) 

Wi-Fi connectivity. 

 

EVlinking  Wi-Fi  is  a  hardware  module  with  Wi-Fi  connectivity  that  can  be  connected  to  our 

EPoCA compatible  controllers  to  access  the  functions  of  the EPoCA  cloud  platform  or  those  of 

other control or data acquisition systems using the MODBUS TCP protocol. 

The  EVlinking  Wi-Fi  module  can  also  be  connected  to  third-party  devices  using  the  MODBUS 

RTU protocol on the RS-485 port to allow integration with client systems. 

 

Available models 

Purchasing codes 

Communication port 

Connectivity 

EVIF25TWX 

TTL MODBUS 

Wi-Fi 

EVIF25SWX 

RS-485 MODBUS 

Wi-Fi 

 

 

Installer manual 

 

MEASUREMENTS AND INSTALLATION 

Measurements in mm (inches); to be fitted on rigid support, with cable tie (not provided). 

EVIF25TWX: 

 

 

EVIF25SWX: 

 

 

INSTALLATION PRECAUTIONS 

Ensure  that  the  working  conditions  are  within  the  limits  stated  in  the  TECHNICAL 

SPECIFICATIONS section 

Do not install the device close to heat sources, equipment with a strong magnetic field, 

in places subject to direct sunlight, rain, damp, excessive dust,  mechanical vibrations 

or shocks 

In compliance with safety regulations, the device must be installed properly to ensure 

adequate  protection  from  contact  with  electrical  parts.  All  protective  parts  must  be 

fixed in such a way as to need the aid of a tool to remove them. 

 

ELECTRICAL CONNECTION 

 

 

N.B. 

-  The  compatibility  of  the  controller  with  the  remote  monitoring  system  EPoCA  and 

the possibility to power EVlinking Wi-Fi from the controller depends on the kind of 

controller. Consult the document "EPoCA - List of compatible controllers" available 

on the web site www.evco.it and/or the controller label 

-  If EVlinking Wi-Fi must be powered with independent power supply, do not power it 

with the same power source of the controller connected to EVlinking Wi-Fi 

-  The battery of EVlinking Wi-Fi is charged by the power supply of the device or by 

the  independent  power  supply:  for  correct  operation,  the  battery  must  be  fully 

charged at least once a year 

-  To reduce any electromagnetic interference connect the power cables as far away 

as  possible  from  the  signal  cables  and  make  the  RS-485  connection  by  using  a 

twisted pair. 

 

2.1 

Example of electrical connection to a controller with TTL MODBUS port 

In this example the controller is capable of powering the device. 

 

 

 

 

 

 

In this example the controller is not capable of powering the device. 

 

 

 

2.2 

Example of electrical connection to a controller with RS-485 MODBUS port 

In this example the controller is capable of powering the device. 

 

 

 

In this example the controller is not capable of powering the device. 

 

 

 

PRECAUTIONS FOR ELECTRICAL CONNECTION 

If  the  device  has  been  moved  from  a  cold  to  a  warm  place,  the  humidity  may  have 

caused  condensation  to  form  inside.  Wait  about  an  hour  before  connecting  it  to  the 

controller 

Disconnect the device from the controller before doing any type of maintenance 

For repairs and for further information, contact the EVCO sales network. 

 

MEANING OF LEDS 

 

LED 

 

ON 

 

OFF 

 

SLOW FLASHING 

 

QUICK 

FLA-

SHING 

MODBUS 

(L1, red) 

 

no  MODBUS  ac-

tivity 

MODBUS activity 

 

 

Wi-Fi 

(L2, green) 

 

 

 

connection  both 

to 

the 

Wi-Fi 

network  and  to 

the Cloud server 

 

 

 

 

 

no  connection  to 

the  Wi-Fi  net-

work 

 

 

connection 

to 

the  Wi-Fi  net-

work, no connec-

tion to the Cloud 

server 

 

FIRST-TIME USE 

1. 

Install  following  the  instructions  given  in  the  section  MEASUREMENTS AND INSTALLA-

TION

2. 

Power up the controller; see the relative instruction sheet. 

3. 

Configure the controller. 

 

Recommended configuration parameters for first-time use. 

PAR. 

DEF. 

PARAMETER 

MIN... MAX. 

bLE 

enable EVlinking 

0  = no 

1  = yes 

rE0 

15 

data-logger sampling interval 

0... 240 min 

rE1 

- - - 

recorded data 

according to the controller 

 

4. 

Disconnect the controller from the mains. 

5. 

Connect the MODBUS port of the device to the MODBUS port of the controller as shown 

in the section ELECTRICAL CONNECTION

6. 

If the device needs independent power supply, power up the device. 

7. 

Power up the controller and an internal test will be run. 

 

The  test  normally  takes  a  few  seconds,  when  it  is  finished  the  LED  of  the  device  will 

switch off. 

8. 

If the controller shows the label “rtc” flashing, set the date and time. 

 

Do not disconnect the controller from the mains in the two minutes following the setting 

of the date and time. 

9. 

Activate the Wi-Fi of a mobile device, localize the network called "Epoca" followed by a 

suffix made of 6 number and letters (for example “Epoca279A62”) and connect it to 

the mobile device using password “epocawifi”; always verify the password on the label 

of the device. 

10. 

For more information see the Installer manual. 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS 

 

Container: 

Black, self-extinguishing. 

Category of heat and fire resistance: 

D. 

Measurements: 

176.0 x 30.0 x 25.0 mm (6 15/16 x 1 3/16 x 

1 in) the models with TTL MODBUS port 

78.0 x 30.0 x 25.0 mm (3 1/16 x 1 3/16 x 1 

in) the models with RS-485 MODBUS port. 

Mounting methods for the control device: 

 

On  rigid  support,  with  cable  tie  (not  provid-

ed). 

Degree  of  protection  provided  by  the  cover-

ing: 

IP00. 

 

Connection method: 

Removable screw terminal block for wires up 

to 1,5 mm² and Pico-Blade connector for the 

models with TTL MODBUS port 

Removable screw terminal block for wires up 

to  1,5  mm²  for  the  models  with  RS-485 

MODBUS port. 

Maximum permitted length for connection cables: 

Power supply: 10 m (32.8 ft) 

RS-485 MODBUS port: 1,000 m (3,280 ft).

 

Operating temperature:

 

From 0 to 55 °C (from 32 to 131 °F).

 

Storage temperature:

 

From -25 to 70 °C (from -13 to 158 °F).

 

Operating humidity: 

 

Relative humidity  without  condensate  from  5 

to 95%.

 

Compliance: 

RoHS 2011/65/CE 

WEEE 2012/19/EU 

REACH (EC) Regulation no. 1907/2006 

RED 2014/53/EU. 

Power supply: 

 

 

powered  by  the  controller  or  12  VAC  ±15  o 

15  VDC  ±15%,  50/60  Hz  (±3  Hz),  max. 

3.2 VA/2W. 

Software class and structure: 

A. 

Clock: 

Secondary lithium battery. 

Clock drift:

 

≤ 60s/month at 25°C (77 °F)

.

 

Clock  battery  autonomy  in  the  absence  of  a 

power supply:

 

> 6 months at 25 °C (77 °F). 

 

Clock battery charging time: 

 

 

 

24h  (the  battery  is  charged  by  the  power 

supply of the device). 

For  correct  operation,  the  battery  must  be 

fully charged at least once a year.

 

Displays: 

 

MODBUS  and  Wi-Fi  communication  status 

LED. 

Communications ports: 

 

1  TTL  MODBUS  slave  port  or  RS-485  MOD-

BUS port (according to the model). 

Connectivity: 

Wi-Fi. 

Wi-Fi output power (EIRP): 

 

11b:  67.5  mW  and  11g:  71.1  mW,  11n 

(HT20) 56.5 mW 

Wi-Fi frequency range: 

2,412... 2,472 MHz. 

 

ITALIANO 

alimentato dal controllore o alimentazione 12 VAC/15 VDC 

orologio 

porta TTL MODBUS o RS-485 MODBUS (a seconda del modello) 

connettività Wi-Fi. 

 

EVlinking  Wi-Fi  is  a  hardware  module  with  Wi-Fi  connectivity  that  can  be  connected  to  our 

EPoCA compatible  controllers  to  access  the  functions  of  the EPoCA  cloud  platform  or  those  of 

other control or data acquisition systems using the MODBUS TCP protocol. 

The  EVlinking  Wi-Fi  module  can  also  be  connected  to  third-party  devices  using  the  MODBUS 

RTU protocol on the RS-485 port to allow integration with client systems. 

 

Modelli disponibili 

Codici di acquisto 

Porta di comunicazione 

Connettività 

EVIF25TWX 

TTL MODBUS 

Wi-Fi 

EVIF25SWX 

RS-485 MODBUS 

Wi-Fi 

 

 

Manuale installatore 

 

DIMENSIONI E INSTALLAZIONE 

Dimensioni in mm (in); installazione su supporto rigido, con fascetta stringicavo (non in dota-

zione). 

EVIF25TWX: 

 

 

EVIF25SWX: 

 

 

AVVERTENZE PER L’INSTALLAZIONE 

accertarsi che le condizioni di lavoro rientrino nei limiti riportati nel capitolo DATI TEC-

NICI 

non installare il dispositivo in prossimità di fonti di calore, di apparecchi con forti ma-

gneti, di luoghi soggetti alla luce solare diretta, pioggia, umidità, polvere eccessiva, vi-

brazioni meccaniche o scosse 

in conformità alle normative sulla sicurezza, la protezione contro eventuali contatti con 

le parti elettriche deve essere assicurata mediante una corretta installazione; tutte le 

parti che assicurano la protezione devono essere fissate in modo tale da non poter es-

sere rimosse senza l’aiuto di un utensile. 

 

 

 

 

 

 

 

 